Artículos de revistas
SSNTD Technique in Photo-neutron Applications
Fecha
2015-06Autor
Sajo Bohus, Laszlo
Vega Carrillo, Héctor René
Singh, Vishwanath
Institución
Resumen
Passive Solid State Nuclear Track Detectors (SSNTDs) are a versatile tool for neutron
studies as has been shown long ago and several good quality materials are commercially available.
They are useful for charged particle detection in the linear energy transfer (LET) range above the
threshold value of ~10 keV μm-1. Linacs, operating above 6 MeV up to the energy region where
radiotherapy is applied usually up to ~25MeV, induce unwanted photo-neutron field; their spectra
shows two components due to reaction dynamics based on evaporation and knock-on mechanisms.
Neutrons produced by Linacs are often neglected in health application; however, today it has
become necessary to assess the effect on patient, staff and radiation workers. Radiation studies
using SSNTDs play a major role in this case. Other fields also take advantage of the passive
detectors properties; in fact they are employed with success to measure neutron signals relevant for
plasma diagnostics as it was demonstrated at the RFX facility as part of the ITER project. The
PADC-NTD techniques provide information on external neutron field values around the RFXinstallation
during pulsed operation. In any case, converter materials, as charged particles from (n,
p) and (n, α) reactions, are required to produce neutron fingerprints through latent tracks. These
once etched provide information on neutron fluence spatial values. Track histograms are then
employed to determine photo-neutron induced damage in materials as well as radiation dose to both
patient and professionally exposed workers. The estimated neutron fluence that can be determined
by NTM covers a large range of values, the largest being above 1010 (± 12%) neutrons/cm2.