dc.creatorSajo Bohus, Laszlo
dc.creatorVega Carrillo, Héctor René
dc.creatorSingh, Vishwanath
dc.date.accessioned2019-03-19T15:17:06Z
dc.date.accessioned2022-10-14T15:13:45Z
dc.date.available2019-03-19T15:17:06Z
dc.date.available2022-10-14T15:13:45Z
dc.date.created2019-03-19T15:17:06Z
dc.date.issued2015-06
dc.identifier1662-9779
dc.identifierhttp://localhost/xmlui/handle/20.500.11845/793
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/4247203
dc.description.abstractPassive Solid State Nuclear Track Detectors (SSNTDs) are a versatile tool for neutron studies as has been shown long ago and several good quality materials are commercially available. They are useful for charged particle detection in the linear energy transfer (LET) range above the threshold value of ~10 keV μm-1. Linacs, operating above 6 MeV up to the energy region where radiotherapy is applied usually up to ~25MeV, induce unwanted photo-neutron field; their spectra shows two components due to reaction dynamics based on evaporation and knock-on mechanisms. Neutrons produced by Linacs are often neglected in health application; however, today it has become necessary to assess the effect on patient, staff and radiation workers. Radiation studies using SSNTDs play a major role in this case. Other fields also take advantage of the passive detectors properties; in fact they are employed with success to measure neutron signals relevant for plasma diagnostics as it was demonstrated at the RFX facility as part of the ITER project. The PADC-NTD techniques provide information on external neutron field values around the RFXinstallation during pulsed operation. In any case, converter materials, as charged particles from (n, p) and (n, α) reactions, are required to produce neutron fingerprints through latent tracks. These once etched provide information on neutron fluence spatial values. Track histograms are then employed to determine photo-neutron induced damage in materials as well as radiation dose to both patient and professionally exposed workers. The estimated neutron fluence that can be determined by NTM covers a large range of values, the largest being above 1010 (± 12%) neutrons/cm2.
dc.languageeng
dc.publisherTrans Tech Publications Inc
dc.relationgeneralPublic
dc.rightshttp://creativecommons.org/licenses/by-nc-sa/3.0/us/
dc.rightsAtribución-NoComercial-CompartirIgual 3.0 Estados Unidos de América
dc.sourceSolid State Phenomena Vol, 239, junio 2015, pp 180-214
dc.titleSSNTD Technique in Photo-neutron Applications
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución