Buscar
Mostrando ítems 1-10 de 22
Influence of the Connector and Implant Design on the Implant-Tooth-Connected Prostheses
(Wiley-Blackwell, 2010-01-01)
Purpose:The purpose of this study was to evaluate stress transfer patterns between implant-tooth-connected prostheses comparing rigid and semirigid connectors and internal and external hexagon implants.Materials and ...
Human non-decalcified histology of three dental implants 45 months under function-a case report
(Springer, 2019-09-25)
Background Fracture of an implant is a quite rare event but represents an important opportunity to evaluate the peri-implant bone tissue response to implant overload in human beings. This study aimed to evaluate bone tissue ...
Photoelastic comparison of single tooth implant-abutment-bone of platform switching vs conventional implant designs
(2011-03-01)
Objectives: The maintenance and stability of peri-implantar soft tissue seem to be related to the crestal bone around the implant platform and different implant designs connections might affect this phenomenon. The aim of ...
Reaction of rat connective tissue to implanted dentin tubes filled with a white mineral trioxide aggregate.
(2002-03-01)
The purpose of this paper was to study the reaction of rat subcutaneous connective tissue to the implantation of dentin tubes filled with white mineral trioxide aggregate (MTA), a material that will be marketed. The tubes ...
Experimental peri-implant tissue breakdown around different dental implant surfaces: Clinical and radiographic evaluation in dogs
(2004-11-01)
Purpose: Tissue reactions to 4 different implant surfaces were evaluated in regard to the development and progression of ligature-induced peri-implantitis. Materials and Methods: In 6 male mongrel dogs, a total of 36 dental ...
Effect of axial loads on implant-supported partial fixed prostheses by strain gauge analysis
(2011-11-01)
Objectives: The present study used strain gauge analysis to perform an in vitro evaluation of the effect of axial loading on 3 elements of implant-supported partial fixed prostheses, varying the type of prosthetic cylinder ...
Microbiologic and radiographic analysis of ligature-induced peri-implantitis with different dental implant surfaces
(2003-09-29)
Purpose: The goal of this study was to evaluate microbiota and radiographic peri-implant bone loss associated with ligature-induced peri-implantitis. Materials and Methods: Thirty-six dental implants with 4 different ...
A comparison between cutting torque and resonance frequency in the assessment of primary stability and final torque capacity of standard and TiUnite single-tooth implants under immediate loading
(2004-01-01)
Purpose: In this study, standard Brånemark System implants and Brånemark TiUnite implants were evaluated regarding primary stability and placement torque. The correlation between placement torque and primary stability as ...
Use of buccal fat pad in the treatment of peri-implant mucosal defect: A case report
(2020-04-01)
The present study describes a clinical case in which the buccal fat pad (BFP) was used to improve the contour of the peri-implant mucosa. To our knowledge, this is the first case report of such an application in the ...
Evaluation of Bone Insertion Level of Support Teeth in Class I Mandibular Removable Partial Denture Associated With an Osseointegrated Implant: A Study Using Finite Element Analysis
(Lippincott Williams & Wilkins, 2011-06-01)
Purpose: This study evaluated the influence of distal extension removable partial denture associated with implant in cases of different bone level of abutment tooth, using 2D finite element analysis.Materials and Methods: ...