Continuation Power Flow: A Parameterization Technique and Adaptive Step Size Control
(2021-01-01)
The electricity sector, especially in emerging countries, has experienced several transformations, mainly resulting from the increase in electricity demand. These events encourage more investment in the generation sector ...
Alternative parameterization for assessing branch outages by a continuation method
(2004-12-01)
This paper proposes and tests new parameters, namely the voltage magnitudes, phase angles and the total power losses, for evaluating the effects of branch outages. The approach can be used as a verification tool after a ...
Parameterization technique for the continuation power flow using the trivial and tangent predictor
(2012-11-01)
This paper presents efficient geometric parameterization techniques using the tangent and the trivial predictors for the continuation power flow, developed from observation of the trajectories of the load flow solution. ...
An Improved Parameterization Technique for the Continuation Power Flow
(IEEE, 2010-01-01)
Continuation methods have been long used in P-V curve tracing due to their efficiency in the resolution of ill-conditioned cases, with close to singular Jacobian matrices, such as the maximum loading point of power systems. ...
Continuation method parameterized by power losses
(2000-01-01)
The conventional load flow methods are considered to be inadequate to obtain the maximum loading point (MLP) due to ill-conditioning problems at and near this critical point. As far as the Newton method is concerned, the ...
Continuation load flow method parameterized by transmission line power losses
(2000-01-01)
The conventional load flow methods are considered to be inadequate to obtain the maximum loading point (MLP) due to ill-conditioning problems at and near this critical point. As far as the Newton method is concerned, the ...
An improved parameterization technique for the continuation power flow
(2010-07-26)
Continuation methods have been long used in P-V curve tracing due to their efficiency in the resolution of ill-conditioned cases, with close to singular Jacobian matrices, such as the maximum loading point of power systems. ...
New parameterization schemes for the continuation load flow method
(2000-01-01)
The conventional load flow methods are considered to be inadequate to obtain the maximum loading point (MLP) due to ill-conditioning problems at and near this critical point. As far as the Newton method is concerned, the ...
Numerical experiments to the Subtropical Cyclone "Anita" using WRF model
(Sociedade Brasileira de MeteorologiaFlorianópolis, 2013)
The Wheater Research and Forecasting Model (WRF) were used to simulate the
subtropical cyclone Anita, which occurred between March 4 and 12 of 2010. These cyclone
instigated weather forecast centers around the world, ...