Buscar
Mostrando ítems 1-10 de 19
GEANT4 tuning for pCT development
(2011-09-09)
Proton beams in medical applications deal with relatively thick targets like the human head or trunk. Thus, the fidelity of proton computed tomography (pCT) simulations as a tool for proton therapy planning depends in the ...
Comparison of the GEANT4 releases 8.2 and 9.2 in terms of a pCT reduced calibration curve
(2010-12-01)
The GEANT4 simulations are essential for the development of medical tomography with proton beams pCT. In the case of thin absorbers the latest releases of GEANT4 generate very similar final spectra which agree well with ...
The comparison of Monte Carlo simulations with GEANT4 for polyethylene absorber within the pCT development
(2011-01-01)
Proton beams in medical applications deal with relatively thick targets like the human head or trunk. Thus, the fidelity of proton computed tomography (pCT) simulations as a tool for proton therapy planning depends in ...
Comparison of GEANT4 Simulations with Experimental Data for Thick Al Absorbers
(Amer Inst Physics, 2009-01-01)
Proton beams in medical applications deal with relatively thick targets like the human head or trunk. Therefore, relatively small differences in the total proton stopping power given, for example, by the different models ...
Comparison of GEANT4 simulations with experimental data for thick al absorbers
(2009-11-27)
Proton beams in medical applications deal with relatively thick targets like the human head or trunk. Therefore, relatively small differences in the total proton stopping power given, for example, by the different models ...
The GeantV project: preparing the future of simulation
(Iop Publishing Ltd, 2015-01-01)
Detector simulation is consuming at least half of the HEP computing cycles, and even so, experiments have to take hard decisions on what to simulate, as their needs greatly surpass the availability of computing resources. ...
Comparison of the GEANT4 Releases 8.2 and 9.2 in terms of a pCT Reduced Calibration Curve
(Ieee, 2010-01-01)
The GEANT4 simulations are essential for the development of medical tomography with proton beams - pCT. In the case of thin absorbers the latest releases of GEANT4 generate very similar final spectra which agree well with ...
Performance of GeantV em Physics Models
(2017-11-23)
The recent progress in parallel hardware architectures with deeper vector pipelines or many-cores technologies brings opportunities for HEP experiments to take advantage of SIMD and SIMT computing models. Launched in 2013, ...