Buscar
Mostrando ítems 1-10 de 36
Failure of miniplate osteosynthesis for the management of atrophic mandibular fracture
(2013-07-01)
Fractures of the severely atrophic (<10 mm) edentulous mandible are not common, and these fractures with a vertical height of 10 mm or less have long been recognized as being particularly problematic. Although there are ...
Rigid internal fixation with titanium versus bioresorbable miniplates in the repair of mandibular fractures in rabbits
(2005-03-01)
The purpose of this study was to compare by qualitative histology the efficacy of rigid internal fixation with titanium system and the Lacto Sorb® system in mandibular fractures in rabbits. Thirty male adult rabbits ...
Mandibular Angle Fracture Treated With New Three-Dimensional Grid Miniplate
(Lippincott Williams & Wilkins, 2012-09-01)
Fractures of the mandibular angle deserve particular attention because they represent the highest percentage of mandibular fractures and have the highest postsurgical complication rate, making them the most challenging and ...
A visão do ortopedista brasileiro sobre a descarga parcial de peso em ortostase nas fraturas expostas da diáfise da tíbia após osteossíntese
(Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia, 2009-12-01)
BACKGROUND: Tibial shaft fractures are the most frequent among long bone fractures. They are described in the literature according to the device and method of treatment, with recommendations that range from full weight ...
Minimally Invasive Osteosynthesis with a Bridge Plate Versus a Functional Brace for Humeral Shaft Fractures
(Journal Bone Joint Surgery, 2017)
Background: Nonoperative treatment has historically been considered the standard for fractures of the shaft of the humerus. Minimally invasive bridge-plate osteosynthesis for isolated humeral shaft fractures has been proven ...
Treatment of distal fractures of the tibia
(Atha Comunicacao & Editora, 2009-01-01)
Objective: to compare the results of fibula fixation (or non fixation) in the treatment of fractures located in the distal third of the tibia, by using intramedullary nailing and bridge plate. Method: 47 fractures on 47 ...
In vitro biomechanical evaluation of sagittal split osteotomy fixation with a specifically designed miniplate
(2013-03-01)
Recent studies have evaluated many methods of internal fixation for sagittal split ramus osteotomy (SSRO), aiming to increase stability of the bone segments while minimizing condylar displacement. The purpose of this study ...
Iliac osteosynthesis with nylon clamp associated to polymethylmethacrylate bone cement - experimental study in dogs cadavers
(Univ Federal Rural Pernambuco, 2015)
Treatment of Displaced Midshaft Clavicle Fractures: Figure-of-Eight Harness Versus Anterior Plate Osteosynthesis A Randomized Controlled Trial
(Lippincott Williams & Wilkins, 2017)
Background: Most midshaft clavicle fractures affect the economically active population, which is negatively impacted by transient limb impairment during the treatment. There is still debate about the advantages and ...