dc.creator | Nelson, Muñoz P. | |
dc.creator | Marcelo, Rodríguez G. | |
dc.creator | Nicolás, Campaña W. | |
dc.creator | Solange, Agar F. | |
dc.creator | Gonzalo, Campaña V. | |
dc.date.accessioned | 2022-08-31T14:37:04Z | |
dc.date.accessioned | 2024-05-02T14:52:35Z | |
dc.date.available | 2022-08-31T14:37:04Z | |
dc.date.available | 2024-05-02T14:52:35Z | |
dc.date.created | 2022-08-31T14:37:04Z | |
dc.date.issued | 2018 | |
dc.identifier | Revista Chilena de Cirugia Volume 70, Issue 3, Pages 224 - 232 2018 | |
dc.identifier | 03793893 | |
dc.identifier | https://repositorio.unab.cl/xmlui/handle/ria/23693 | |
dc.identifier | 10.4067/s0718-40262018000300224 | |
dc.identifier.uri | https://repositorioslatinoamericanos.uchile.cl/handle/2250/9259811 | |
dc.description.abstract | La efectividad de la colonoscopia depende de múltiples factores, destacando la calidad
de preparación intestinal y la tolerabilidad que tenga el paciente a la preparación administrada. Objetivo: Comparar dos agentes de preparación intestinal, el polietilenglicol (PEG) y el picosulfato de sodiocitrato de magnesio (PSCM) en términos de efectividad y tolerabilidad de la preparación. Pacientes y
Método: Ensayo clínico aleatorizado en pacientes ambulatorios sometidos a colonoscopia en Clínica
INDISA. Evaluando efectividad y tolerabilidad con el Boston Bowel Preparation Score (BBPS) y cuestionario de Lawrence [compuesto por escala Likert, dos preguntas cualitativas y escala visual análoga
(EVA)], respectivamente. Resultados: 189 pacientes, de los cuales 123 se aleatorizaron a PEG y 66 a
PSCM. El BBPS en los pacientes que utilizaron PEG, la media fue 7,51 (DS 1,66) y con PSCM fue 7,12
(DS 1,71) (p = 0,111). Al analizar la tolerabilidad con escala Likert, la media con PEG fue 0,94 (DS 0,68)
y con PSCM fue 0,63 (DS 0,61) (p = 0,0004). La EVA con PEG tuvo una media de 7,68 (DS 2,4) y con
PSCM de 9,04 (DS 1,59) (p < 0,0001). Al preguntar ausentismo laboral, no hubo diferencias significativas en ambos grupos y al preguntar si ocuparía la misma preparación en una futura colonoscopia, hubo
significancia estadística a favor del PSCM (p = 0,026). Conclusión: No encontramos diferencias en la
efectividad de preparación intestinal al comparar PEG y PSCM, sin embargo, el PSCM es mejor tolerado. | |
dc.description.abstract | The effectiveness of colonoscopy depends on multiple factors, being two of the most important ones an adequate bowel preparation and the patient’s tolerability to the preparation. Objectives: Compare effectiveness and tolerability of two bowel preparation agents, polyethylene glycol (PEG) and sodium picosulfate/magnesium citrate (SPMC). Patients and Methods: Randomized clinical trial on outpatients that went into colonoscopy in INDISA Clinic. We evaluated effectiveness and tolerability with Boston Bowel Preparation Score (BBPS) and Lawrence questionnaire [composed by Likert scale, two qualitative questions and Visual Analogue Scale (VAS) for pain], respectively. Results: 189 patients, 123 were randomized to PEG and 66 to SPMC. BBPS average in patients in the PEG branch was 7.51 (SD 1.66) and for SPMC 7.12 (SD 1.71) (p = 0.111). Likert scale for evaluating tolerability average for PEG was 0.94 (SD 0.68) and for SPMC 0.63 (SD 0.61) (p = 0.0004). VAS scale for PEG had an average of 7.68 (SD 2.4) and for PSCM 9.04 (SD 1.59) (p < 0.0001). When we asked for workplace absenteeism, there were no significant differences between both groups and when we asked about using the same intestinal preparation in a future colonoscopy there was statistical significance in favor to SPMC (p = 0.026). Conclusions: No differences were noted on effectiveness between the PEG and SPMC bowel preparations. Nevertheless, SPMC appeared to be better tolerated by patients. © 2018, Sociedad de Cirujanos de Chile. All rights reserved. | |
dc.language | es | |
dc.publisher | Sociedad de Cirujanos de Chile | |
dc.subject | Soluciones para preparación intestinal | |
dc.subject | Colonoscopia | |
dc.subject | Polietilenglicoles | |
dc.subject | Picosulfato de sodio | |
dc.subject | Agente catártico | |
dc.subject | Citrato de magnesio | |
dc.title | Evaluación comparativa de efectividad y tolerabilidad con polietilenglicol y picosulfato de sodio-citrato de magnesio como agentes de preparación intestinal para colonoscopia | |
dc.type | Artículo | |