Correlation between the blood pressure measurement in office and ambulatory monitoring in hypertensive patients in Medellín, Colombia

dc.creatorPatiño Giraldo, Santiago
dc.creatorToro Escobar, Juan Manuel
dc.creatorJaramillo Gómez, Carlos José
dc.creatorGarcía García, Héctor Iván
dc.creatorGiraldo Restrepo, Mónica Lucía
dc.date2023-04-07T19:32:41Z
dc.date2023-04-07T19:32:41Z
dc.date2013
dc.date.accessioned2024-04-23T14:21:22Z
dc.date.available2024-04-23T14:21:22Z
dc.identifier0120-5633
dc.identifierhttps://hdl.handle.net/10495/34545
dc.identifier10.1016/S0120-5633(13)70054-8
dc.identifier2357-3260
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/9229577
dc.descriptionRESUMEN: Introducción: investigaciones recientes refieren mayor correlación entre la monitorización ambulatoria de la presión arterial (MAPA) y el compromiso de órgano blanco. Este estudio busca establecer la correlación entre la medición de la presión arterial en consultorio y la MAPA en pacientes con diagnóstico reciente de hipertensión arterial. Métodos: pacientes con diagnóstico reciente de hipertensión arterial sin otros factores de riesgo cardiovascular. Se realizó toma de presión arterial en consultorio y MAPA. Se evaluó correlación entre las mediciones de presión arterial en consultorio y variables de la MAPA. Se categorizó el control de la hipertensión arterial de acuerdo con las guías del Joint National Committee 7 y la American Heart Association. Resultados: se hicieron 239 MAPA en 149 sujetos con una media (DE) de presión arterial sistólica y presión arterial diastólica clínica de 134,5 (13,8) mm Hg y 87,5 (9) mm Hg y en 24 horas de 129 (10,4) mm Hg y 80,1 (7,5) mm Hg, respectivamente, con una diferencia de -4,95mm Hg (IC95%: -2,7; -7,2) y -7,4mm Hg (IC95%: -5,9; -8,9) con respecto a la presión arterial clínica. Se encontró correlación entre la presión arterial clínica y las variables de MAPA (presión arterial sistólica r=0,4; p<0,01, presión arterial diastólica r=0,48; p < 0,01). Para el control de la presión arterial con la toma clínica se encontró 43,7% de sensibilidad y 72,4% de especificidad en comparación con el otro método. Conclusión: existe correlación positiva entre la medición de la presión arterial clínica y por MAPA, pero la sensibilidad y especificidad de una sola medición en consultorio con respecto a la MAPA, la hace insuficiente para verificar el control de la presión arterial.
dc.descriptionABSTRACT: Introduction: recent studies reported higher correlation between ambulatory blood pressure monitoring (ABPM) and end-organ damage. This study aims to establish the correlation between office blood pressure measurement (OBPM) and ABPM in patients with newly diagnosed hypertension. Methods: patients newly diagnosed with hypertension without other cardiovascular risk factors. OBPM and ABPM were performed. We evaluated the correlation between OBPM and ABPM variables. Hypertensive control was categorized in accordance with the Joint National Committee 7 and American Heart Association guidelines. Results: 239 ABPM in 149 subjects with a mean (SD) office SBP and DBP 134.5 (13.8) mmHg and 87.5 (9) mmHg and 24-hours SBP of 129 (10.4) mmHg and 24-hours DBP 80.1 (7.5) mmHg, a difference of -4.95mmHg (95% CI: -2.7, -7.2) and -7.4mmHg (95% CI: -5.9, -8.9) with respect to office BP. Positive correlation was found between office BP and ABPM variables (SBP r=0.4, p <0.01, DBP r=0.48, p <0.01).Sensitivity and specificity of office BP versus AMPB for hypertensive control were 43.7% and 72.4% respectively. Conclusion: there is positive correlation between OBPM and ABPM, but the sensitivity and specificity of a single measurement at office with regard to ABPM, makes it inadequate for evaluation of hypertensive control.
dc.descriptionCOL0036212
dc.descriptionCOL0007121
dc.descriptionCOL0012426
dc.format8
dc.formatapplication/pdf
dc.formatapplication/pdf
dc.languagespa
dc.publisherSociedad Colombiana de Cardiología y Cirugía Cardiovascular
dc.publisherGrupo Académico de Epidemiología Clínica
dc.publisherInformed
dc.publisherInmunodeficiencias Primarias
dc.publisherBogotá, Colombia
dc.relationRev. Colomb. Cardiol.
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/2.5/co/
dc.rightshttp://purl.org/coar/access_right/c_abf2
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectMonitoreo Ambulatorio de la Presión Arterial
dc.subjectBlood Pressure Monitoring, Ambulatory
dc.subjectHipertensión Arterial Pulmonar
dc.subjectPulmonary Arterial Hypertension
dc.subjectPresión Arterial
dc.subjectArterial Pressure
dc.subjectHipertensión
dc.subjectHypertension
dc.subjectMonitoreo Ambulatorio de la Presión Arterial
dc.subjectBlood Pressure Monitoring, Ambulatory
dc.subjectSensibilidad y Especificidad
dc.subjectSensibilidade e Especificidade
dc.titleCorrelación entre la Medición en consultorio y la monitorización ambulatoria de la presión arterial en pacientes hipertensión de Medellín, Colombia
dc.titleCorrelation between the blood pressure measurement in office and ambulatory monitoring in hypertensive patients in Medellín, Colombia
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion
dc.typehttp://purl.org/coar/resource_type/c_2df8fbb1
dc.typehttps://purl.org/redcol/resource_type/ART
dc.typeArtículo de investigación


Este ítem pertenece a la siguiente institución