dc.contributorNascimento, Jussara Pereira do
dc.contributorLeite, José Paulo Gagliardi
dc.contributorBonaldo, Myrna Cristina
dc.contributorGarcia, Rita de Cássia Nasser Cubel
dc.contributorTeixeira, Maria da Glória Martins
dc.creatorSilveira, Waldemir de Castro
dc.date2012-11-13T12:18:47Z
dc.date2012-11-13T12:18:47Z
dc.date2005
dc.date.accessioned2023-09-26T23:21:09Z
dc.date.available2023-09-26T23:21:09Z
dc.identifierSILVEIRA, Waldemir de Castro. Desenvolvimento de teste rápido para detecção de rotavírus: imunoensaio de captura e aglutinação em látex. 2005. 61 f. Dissertação (Mestrado Profissional em Tecnologia de Imunobiológicos) – Instituto de tecnologia em Imunobiológicos, em parceria com o Instituto Oswaldo Cruz, Fundação Oswaldo Cruz, Rio de Janeiro, 2005.
dc.identifierhttps://www.arca.fiocruz.br/handle/icict/5796
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/8889634
dc.descriptionO rotavírus humano (RV) pode ser detectado prontamente pelo método de aglutinação do látex (LTE), com elevada sensibilidade e especificidade, através da reação cruzada com o anticorpo anti-rotavírus decarneiro. As partículas de látex revestidas com a imunoglobulina G anti-rotavírus, são especificamente aglutinadas na presença do RV, com resultados macroscopicamente evidentes dentro de poucos minutos. Para a sensibilidade e a especificidade do método de LTE proposto, comparou-se com outro método similar (Rota-Kit Slidex®; BioMérieuxl), um total de 81 amostras fecais de crianças até 5 anos com gastroenterite aguda. Com 36 amostras diarréicas RV-positivos e 45 RV-negativos, a ensibilidade analítica do teste de LTE proposto foi > 99,99%, e a especificidade analítica também foi > 99,99%. O LTE demonstrou ser capaz de detectar partículas de rotavírus em fezes diarréicas em concentrações 20 vezes menores que o limite de detecção do Rota-Kit Slidex®. A freqüência de testes positivos de LTE pareceu ser proporcionalà concentração de viríons na amostra fecal. O LTE demonstrou uma sensibilidade de 94,0% (34 de 36 positivos), e uma especificidade > 99,99% (45de 45 negativas) quando comparado com o Rotazyme II®, um ensaio imunoenzimático (Abbott Laboratories). O método do LTE é rápido, facilmenteutilizável para detectar o RV em amostra fecal de crianças e é apropriado para a aplicação como um teste diagnóstico simples, principalmente para triagem de grandes grupos de pacientes. O LTE é estável por pelo menos 2 anos searmazenado sob refrigeração (4°C) e se mostra útil para laboratórios de pequeno porte, para rotinas ambulatoriais, de emergências e de triagem e finalmente, para discriminar amostras negativas que poderão então ser testadas por testes mais sensíveis.
dc.descriptionHuman rotavírus (HRV) can readily be detected by the latex agglutination assay method (LTE), with raised sensitivity and specificity, based on crossed reaction with the anti-rotavirus sheep antibody. The latex particles coated with anti-rotavirus immunoglobulin G, agglutinates specifically when in contact with HRV in few minutes, with evident macroscopically results. The sensitivity and the specificity performance of the proposed method (LTE), was compared with another similar method (Rota-Kit Slidex®, BioMérieux), a total of 81 specimens from children with acute gastroenteritis were tested. With 36 HRV positive samples and 45 HRV negative samples, the analytical sensitivity of LTE was better than 99,99% and the analytical specificity, also, was better than 99,99%. The LTE demonstrated to be capable to detect particles of HRV in fecal samples in concentrations20 lesser times that the limit of detection of Rota-Kit Slidex®. The frequency of positive tests of LTE seemed to be proportional to the concentration of virions in the fecal sample. The LTE demonstrated a sensitivity of 94,0%(34 of 36 positives), and a specificity >99,99% (45 of 45 negatives) whencompared with Rotazyme II® (Abbott Laboratories). The method of the LTE is fast and easily usable to detect HRV in children fecal sample and is appropriate for application as a test of simple diagnosis, mainly for screening of great groups of patients. The LTE is stable per at least 2 yearsif stored under refrigeration (4°C) and it shows useful for small laboratories, clinic routines, emergence rooms and screenings and finally to discriminate negative samples that could then be tested by more sensible tests.
dc.formatapplication/pdf
dc.languagepor
dc.publisherInstituto de Tecnologia em Imunobiológicos
dc.rightsopen access
dc.subjectRotavírus humano
dc.subjectRotavirus
dc.subjectImunoensaio
dc.subjectAglutinação
dc.subjectLátex
dc.subjectDiarréia
dc.subjectDiagnóstico
dc.subjectHuman rotavirus
dc.subjectRotavirus
dc.subjectImmunoassay
dc.subjectAgglutination
dc.subjectLatex
dc.subjectDiarrhea
dc.subjectDiagnosis
dc.subjectRotavirus
dc.subjectImunoensaio
dc.subjectAglutinação
dc.subjectLátex
dc.subjectDiarréia
dc.subjectDiagnóstico
dc.titleDesenvolvimento de teste rápido para detecção de rotavírus: imunoensaio de captura e aglutinação em látex
dc.typeDissertation


Este ítem pertenece a la siguiente institución