dc.contributorGarcía Mayén, Héctor
dc.creatorAmaya Moya, Johana Milena
dc.date2017-10-28T13:53:49Z
dc.date2017-10-28T13:53:49Z
dc.date2017
dc.date2017-10-28
dc.date.accessioned2023-09-07T15:29:31Z
dc.date.available2023-09-07T15:29:31Z
dc.identifierhttp://hdl.handle.net/10819/4744
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/8733987
dc.descriptionThis project "Acoustic Characterization of an industry in the city of Medellin by sound intensity based on PU probe" is oriented to test a relatively new tool in the world of acoustics, PU Probe (Pressure- Particle velocity), and it describes the theory, procedures, and results of acoustic measurements for the characterization of a plant producing concrete within a construction site by evaluating sound power as proposed in the ISO 8297 standard, based on sound pressure measurements. Then a suggested measurement protocol for estimating noise power based by means of sound intensity measurements with Microflown’s technology PU probe. In order to verify protocol’s applicability, results obtained by both methods were compared, and are presented. The results are sound power levels estimated intensity and sound pressure for controlled conditions in a tube under designed the ASTM E2611-09 standard, and concrete production plant in a construction site. In addition emission noise map industry mentioned in SoundPlan performed using as input variable with the estimated pressure levels measured with PU probe power.
dc.descriptionEl presente proyecto “Caracterización acústica de una industria de la ciudad de Medellín por medio de intensidad sonora basado en sonda PU”, está orientado a probar una herramienta relativamente nueva en el mundo de la acústica, la sonda PU (Presión-Velocidad de partícula). A continuación, se expone la teoría, los procedimientos y resultados de las mediciones acústicas para la caracterización de una planta productora de concreto dentro de una obra de construcción, mediante la evaluación de potencia acústica propuesta en el estándar ISO 8297 basado en presión sonora. Luego se presenta una propuesta de protocolo de medición para la estimación de la potencia acústica basado en intensidad sonora, por medio de la sonda PU de la tecnología Microflown. Con el fin de verificar la aplicabilidad del protocolo propuesto se compararon los resultados obtenidos por ambos métodos. Los resultados obtenidos son los niveles de potencia acústica estimados con intensidad y presión sonora, para condiciones controladas en un tubo diseñado bajo el estándar ASTM E2611-09 y la planta de producción de concreto en una obra de construcción. Además mapa de ruido de emisión de la industria mencionada, realizado en SoundPlan utilizando como variable de entrada la potencia estimada con los niveles de presión medidos con sonda PU.
dc.formatpdf
dc.format72 páginas
dc.formatRecurso en linea
dc.formatapplication/pdf
dc.formatapplication/pdf
dc.languagespa
dc.publisherIngenierias
dc.publisherIngeniería de Sonido
dc.publisherMedellín
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightsAtribución-NoComercial-SinDerivadas 2.5 Colombia
dc.rightsPor medio de este formato manifiesto mi voluntad de AUTORIZAR a la Universidad de San Buenaventura, Sede Bogotá, Seccionales Medellín, Cali y Cartagena, la difusión en texto completo de manera gratuita y por tiempo indefinido en la Biblioteca Digital Universidad de San Buenaventura, el documento académico-investigativo objeto de la presente autorización, con fines estrictamente educativos, científicos y culturales, en los términos establecidos en la Ley 23 de 1982, Ley 44 de 1993, Decisión Andina 351 de 1993, Decreto 460 de 1995 y demás normas generales sobre derechos de autor. Como autor manifiesto que el presente documento académico-investigativo es original y se realiza sin violar o usurpar derechos de autor de terceros, por lo tanto, la obra es de mi exclusiva autora y poseo la titularidad sobre la misma. La Universidad de San Buenaventura no será responsable de ninguna utilización indebida del documento por parte de terceros y será exclusivamente mi responsabilidad atender personalmente cualquier reclamación que pueda presentarse a la Universidad. Autorizo a la Biblioteca Digital de la Universidad de San Buenaventura convertir el documento al formato que el repositorio lo requiera (impreso, digital, electrónico o cualquier otro conocido o por conocer) o con fines de preservación digital. Esta autorización no implica renuncia a la facultad que tengo de publicar posteriormente la obra, en forma total o parcial, por lo cual podrá, dando aviso por escrito con no menos de un mes de antelación, solicitar que el documento deje de estar disponible para el público en la Biblioteca Digital de la Universidad de San Buenaventura, así mismo, cuando se requiera por razones legales y/o reglas del editor de una revista.
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/2.5/co/
dc.source[1] López Acosta, Laura Alejandra; posner Mateus, Samuel; Osorio Gómez, Nicolás;, Predicción de ruido en jornada diurna de un tramo de la A. Boyacá con el funcionamiento de la troncal de transmilenio, utilizando modelos de predicción de Ruido. (Trabajo de grado), Bogotá D.C: Universidad san Buenaventura Bogotá. Facultad de Ingeniería, 2011.
dc.source[2] Fundación Sin Ánimo de Lucro Ecológica (FULECOL); Área Metropolitana del Valle de Aburrá, «Actualización del mapa de ruido de la zona urbana,» Fundación Sin Ánimo de Lucro Ecológica (FULECOL), Medellín, 2011.
dc.source[3] Brüel & Kjær Beyond Measure, «Primer: Sound Intensity,» 1993. [En línea]. Available: https://goo.gl/6YAg3J.
dc.source[4] F.J. Fahy, Sound Intensity, 2 ed., London: E & FN Spon, 1995.
dc.source[5] A. Carrión Isbert, Diseño acústico de espacios arquitectónicos, Barcelona: Edicions UPC , 1998.
dc.source[6] B. &. Kjær, «Sound Intensity,» 2850 Nærum, Denmark, 1988.
dc.source[7] M. Rejano de la Rosa, Ruido industrial y urbano, Paraninfo, Ed., 2000.
dc.source[8] L. E. Kinsler, A. R. Frey, A. B. Coopens y J. V. Sanders, de Fundamentals of Acoustics, 4 ed., New York, 2000.
dc.source[9] Blackstock, D, T., Fundamentals of physical acoustics, Austin, Estados Unidos: John Wiley & Sons, INC, 2000.
dc.source[10] ISO 9614-1, «Acoustics-Determination of sound power levels of noise sources using sound intensity,» Part 1: Measurement at discrete points (Primera ed.), 1993.
dc.source[11] ISO 9614-2:1996, Acoustics -- Determination of sound power levels of noise sources using sound intensity -- Part 2: Measurement by scanning, 1996, p. 19.
dc.source[12] Harris, C. M., Manual de medidas acústicas y control de ruido, Madrid, España: McGrawHill.: (3 ed., Vols. I-II). , 1995 .
dc.source[13] Monica S. Hammer,1 Tracy K. Swinburn,2 and Richard L. Neitzel «Environmental Noise Pollution,» de Environmental Noise Pollution Vol. 122 No 2 .
dc.source[14] ISO 8297 , «Acoustics – Determination of sound power levels of multisource industrial plants for evaluation of sound pressure levels in the enviroment,» 1994.
dc.source[15] ISO Resolución 0627, 2006.
dc.source[16] Brüel&Kjær, «Ruido Ambiental,» Sound & Vibration Measurement A/S, 2005.
dc.source[17] G.R.A.S. Sound & Vibration, «Sound-intensity Probe Type 50AI,» 2006.
dc.source[18] H. E. de Bree y F. Jacobse, A comparison of two different sound intensity, vol. 118, Acoustical Society of America, 2005.
dc.source[19] H. E. de Bree y F. Jacobsen, «Intensity-based sound power determination under adverse sound fiels conditions: p-p probes versus p-u probes,» de Microflown E-book, 2005.
dc.source[20] I. 61672-1, «Electroacoustics - Sound level meters - Part 1: Specifications (IEC 61672- 1:2013)». 2013.
dc.source[21] H-E de Bree, «3 The Microflown,» de THE MICROFLOWN E-BOOK, 2007, p. 30.
dc.source[22] H-E de Bree and W.F. Druyvesteyn, «An acoustic vector sensor based method to measure the,» de Euro Noise , Edinburgh, 2009.
dc.source[23] «Manual Scan & Paint,» 2013. [En línea]. Available: http://www.microflown.com/files/media/library/Manuals/scanpaint_manual.pdf. [Último acceso: 2016].
dc.source[24] J. Ochoa Villegas, «Protocolo de Medición de Holografía Acústica,» Medellín.
dc.source[25] «Good practice guide for strategic noise mapping and the associated data on noise exposure.,» Environmental Protection Agency 2011, 2006.
dc.source[26] H-E de Bree, «Chapter 5a Verification of P-U intensity calculation,» de THE MICROFLOWN E-BOOK, 2001.
dc.source[27] F. Jacobsen y H. E. Bree, «A comparison of two different sound intensity measurement principles,» Acoustical Society of America. Journal, 2005.
dc.source[28] W. R DRUYVESTEYN and H. E. DE BREE, «A Novel Sound Intensity Probe Comparison with the Pair of Pressure Microphones Intensity Probe,» J. Audio Eng. Soc, vol. 48, 2000.
dc.source[29] W. Woszczyk , T. S. . K. O. Masakazu Iwaki y H.-E. de Bree, «Anechoic measurements of particle-velocity probes compared to pressure gradient and pressure microphones,» de Audio Engineering Society Convention Paper 7107, Vienna, Austria, 2007.
dc.source[30] J. A. Molina, Evaluación de los métodos de estimación de potencia sonora basados en presión y en el uso de la sonda p-u microflown para la caracterización acústica de los electrodomésticos de la línea Assento de Haceb, Medellín, 2014.
dc.source[31] F. Jacobsen, «State of the Art of Sound Intensity and Its Measurement and Applications,» Acoustic Technology, Ørsted#DTU, Technical University of Denmark, Building 352, DK- 2800 Lyngby, 2001.
dc.source[32] F. Fahy, «Errors in sound intensity measurement,» de Sound Intensity, London, E & FN SPON, 1989, pp. 247-251.
dc.source[33] Corporación Aceros Arequipa S.A, Manual de Construcción para Maestros de Obra.
dc.source[34] Euge, «El cemento en la construcción,» [En línea]. Available: http://ideasparaconstruir.com/n/4017/el-cemento-en-la-construccion.html. [Último acceso: 05 05 2016].
dc.source[35] «ASTM E2611 - 09: Standard Test Method for Measurement of Normal Incidence Sound Transmission of Acoustical Materials Based on the Transfer Matrix Method,» ASTM, 2009.
dc.source[36] A. F. Montoya Flórez, «Desarrollo y caracterización de un sistema de medición con base en el estándar ASTM E2611-09 para la determinación de la pérdida por transmisión de materiales de la industria colombiana.,» Medellín, 2016.
dc.source[37] Calorcol S.A, «Sonowall SAFB,» Copacabana-Antioquia- Colombia.
dc.source[38] D. Fernández Comesaña, S. Steltenpool, G. Carrillo Pousa, H.-E. de Bree y K. R. Holland, «Scan and Paint: Theory and Practice of a Sound Field Visualization Method,» ISRN Mechanical Engineering, nº Article ID 241958, p. 11, 2013.
dc.source[39] D. Yepes, M. Gomez, L. Sanchez y A. Jaramillo, «Metodología De Elaboración De Mapas AcústicoS,» Grupo de Higiene y Gestión Ambiental, Politécnico Colombiano Jaime Isaza Cadavid , p. 11, 27 Septiembre 2008.
dc.sourceUniversidad de San Buenaventura - Medellín
dc.sourceBiblioteca USB Medellín (San Benito): CD-4151t
dc.sourceBiblioteca Digital Universidad de San Buenaventura
dc.subjectCaracterización de fuente industrial
dc.subjectIntensidad acústica
dc.subjectPresión acústica
dc.subjectPotencia sonora
dc.subjectSonda PU
dc.subjectCharacterization of industrial source
dc.subjectSound intensity
dc.subjectSound pressure
dc.subjectSound power
dc.subjectSensor PU
dc.subjectFuentes acústicas
dc.subjectAcústica
dc.subjectMedición acústicas
dc.subjectEfectos sonoros
dc.subjectResistencia acústica
dc.subjectIntensidad sonora
dc.titleCaracterización acústica de una industria de la ciudad de Medellín por medio de intensidad acústica basado en Sonda PU
dc.typeTrabajo de grado - Pregrado
dc.typeTrabajo de Grado
dc.typeinfo:eu-repo/semantics/bachelorThesis


Este ítem pertenece a la siguiente institución