dc.contributorOliveira, Aécio de Limas
dc.creatorQuatrin, Artur Dala Nora
dc.date.accessioned2023-04-12T12:59:38Z
dc.date.accessioned2023-09-04T19:36:14Z
dc.date.available2023-04-12T12:59:38Z
dc.date.available2023-09-04T19:36:14Z
dc.date.created2023-04-12T12:59:38Z
dc.date.issued2023-02-15
dc.identifierhttp://repositorio.ufsm.br/handle/1/28641
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/8626878
dc.description.abstractThe electric power system comprises generation, transmission and distribution systems. To ensure the operation of this complex system, it is crutial to verify the operation condition of the involved components. Thus, the power equipment insulation is subject to degradation due to the possibility by partial discharges. The ultrasonic measurement is a non-invasive inspection technique of power equipment, which allows checking the insulation degradation through the analysis of acoustic emission data. This work proposes a methodology for partial discharge detection and classifying through the Hilbert-Huang Transform and generalized regression neural networks. The Hilbert-Huang Transform is used to verify behavioral patterns in partial discharges within time frequency domain. In this sense, variables that presented relevant patterns to describe this phenomenon were extracted. A statistical analysis is applied on patterns and analyzed by artificial neural networks in order to classify the database thereby, determinate the existence of partial discharges according to severity by the acoustic signal. As a result, it is noted that the acoustic pulses of partial discharges are more evident with the increase in voltage. Furthermore, the categorization of three behavior patterns was allowed through the investigation of frequency spectrum of the acoustic signals, which were recognized as Background Noise, Moderate Discharge and Several Discharge.
dc.publisherUniversidade Federal de Santa Maria
dc.publisherBrasil
dc.publisherUFSM
dc.publisherCentro de Tecnologia
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.rightsAcesso Aberto
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International
dc.subjectTransformada Hilbert-Huang
dc.subjectinspeção acústica
dc.subjectdesvio padrão
dc.subjectGRNN
dc.subjectpadrões
dc.subjectHilbert-Huang transform
dc.subjectacoustic inspection
dc.subjectstandard deviation
dc.subjectGRNN
dc.subjectpatterns
dc.titleAnálise de medidas ultrassônicas de descargas parciais em sistema ponta-plano por meio da tranformada hilbert-huang e de redes neurais de Regressão generalizada
dc.typeTrabalho de Conclusão de Curso de Graduação


Este ítem pertenece a la siguiente institución