CONCEPTS IN MAGNETIC RESONANCE. PART A, BRIDGING EDUCATION AND RESEARCH;
Concepts Magn. Reson. Part A

dc.creatorIRARRAZABAL-MENA, PABLO
dc.creatorTEJOS-NUÑEZ, CRISTIAN ANDRES
dc.creatorCARDENAS-BLANCO, ARTURO
dc.creatorCAMERON, IAN
dc.date2017-04-27T18:49:19Z
dc.date2022-07-07T01:38:26Z
dc.date2017-04-27T18:49:19Z
dc.date2022-07-07T01:38:26Z
dc.date2008
dc.date.accessioned2023-08-22T03:53:55Z
dc.date.available2023-08-22T03:53:55Z
dc.identifier0
dc.identifierD05I10358
dc.identifierD05I10358
dc.identifierWOS:000261665300001
dc.identifier1546-6086
dc.identifierhttps://hdl.handle.net/10533/196826
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/8317155
dc.descriptionThe aims of this article are to review the properties of noise in magnitude MR images to clarify the terminology used when referring to the noise and to discourage the use of the terms Rician noise and Rician noise bias. The distribution of measured MR pixel intensities in the presence of noise is known to be Rician, and the width of this distribution is directly related to the Gaussian noise on the measured real and imaginary signals. It is the pixel magnitude values that follow the Rician distribution, not the noise. The term Rician noise should be used cautiously or, better still, avoided completely since inherent to this terminology is behavior that is not normally associated with noise, such as dependence on signal strength. This terminology is misleading and can lead to conceptual and practical misunderstandings. It is better to relate the image noise to the Gaussian noise on the real and imaginary signals. (C) 2008 Wiley Periodicals. Inc. Concepts Magn Reson Part A 32A: 409-416, 2008.
dc.descriptionA.C-B. and I.C. thank the Ontario Research and Development Challenge Fund for financial support, the Ottawa Health Research Institute. and Dr. Greo O. Cron. C.T. thanks his grant sponsor Fondecyt (#1060008) for their support.
dc.description8
dc.descriptionFONDEF
dc.descriptionicameron@ottawahospital.on.ca
dc.descriptionOntario Research and Development Challenge Fund; Ottawa Health Research Institute; Fondecyt [1060008]
dc.description6
dc.descriptionFONDEF
dc.description32
dc.languageENG
dc.publisherJOHN WILEY & SONS INC
dc.relationinstname: Conicyt
dc.relationreponame: Repositorio Digital RI2.0
dc.relationinstname: Conicyt
dc.relationreponame: Repositorio Digital RI2.0
dc.relationinfo:eu-repo/grantAgreement/Fondef/D05I10358
dc.relationinfo:eu-repo/semantics/dataset/hdl.handle.net/10533/93477
dc.relationhttps://doi.org/10.1002/cmr.a.20124
dc.rightsinfo:eu-repo/semantics/openAccess
dc.titleNoise in magnitude magnetic resonance images
dc.titleCONCEPTS IN MAGNETIC RESONANCE. PART A, BRIDGING EDUCATION AND RESEARCH
dc.titleConcepts Magn. Reson. Part A
dc.typeArticulo
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion
dc.coverageHOBOKEN


Este ítem pertenece a la siguiente institución