dc.creatorHurtado y de la Peña, Marcela;#0000-0003-3546-5986
dc.creatorMEDINA LOPEZ, JOSE RAUL; 222012
dc.creatorALARCON ANGELES, GEORGINA; 161741
dc.creatorHurtado y de la Peña, Marcela
dc.creatorMedina López, José Raúl
dc.creatorAlarcón Ángeles, Georgina
dc.date.accessioned2023-04-25T21:05:55Z
dc.date.accessioned2023-07-20T16:15:01Z
dc.date.available2023-04-25T21:05:55Z
dc.date.available2023-07-20T16:15:01Z
dc.date.created2023-04-25T21:05:55Z
dc.date.issued2022
dc.identifierhttp://hdl.handle.net/11191/9631
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/7718126
dc.description.abstractSe desarrollaron cuatro sistemas cromatográficos ternarios en gradiente para el análisis cuantitativo de diferentes mezclas de analgésicos/antinflamatorios que suelen combinarse en formas dosificación para potenciar sus efectos. El objetivo de los métodos desarrollados fue lograr la resolución en un tiempo de análisis corto y con características cromatográficas adecuadas. Los sistemas de gradiente requieren estabilizarse en los cambios de condición, prolongando el tiempo de corrida. Las propuestas que aquí se presentan es en columnas de 50 X 4.6 mm C8 y C18 con tamaño de partícula 2.6 y 5 micrometros respectivamente. Como fases móviles: diferentes combinaciones de agua, solución ácida y metanol: acetonitrilo. La detección mediante detector UV, se ajustó a una longitud de onda adecuada al analgésico a determinar. Las condiciones propuestas permiten corridas de gradiente en máximo 10 minutos y con características cromatográficas aceptables.
dc.description.abstractFour ternary chromatographic systems in gradient were developed for the quantitative analysis of different analgesic/anti-inflammatory mixes, which are usually combined in a dosage form to potentialize their effects. The objective of the developed methods was to achieve a resolution in a shorter time and with adequate chromatographic characteristics. The gradient systems, need to stabilize in the condition changes as to modify the mobile phase during the analytic run, since the time of analysis is longer. The proposals here presented are in columns of 50x4.6 mm C8 and C18, with particles sizes of 2.6 and 5 micrometers accordingly. As mobile phases: different combinations of water, acid solution and methanol: acetonitrile. The detection by UV detector was adjusted to the wavelength of each analgesic to be determined. The proposed conditions allow the gradient analytic runs to be done in maximum 10 minutes time, with acceptable chromatographic characteristic peaks.
dc.languagespa
dc.publisherUniversidad Autónoma Metropolitana (México). Unidad Azcapotzalco. División de Ciencias Básicas e Ingeniería.
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/4.0
dc.rightsopenAccess
dc.rightsAtribución-NoComercial-SinDerivadas
dc.sourceRevista Tendencias en Docencia e Investigación en Química. Año 8, número 8 (enero-diciembre de 2022). ISSN: 2448-6663
dc.subjectGradientes de elución, AINEs, paracetamol. Elution gradient, NAIDs, acetaminophen.
dc.titleAnálisis cromatográfico para presentaciones de analgésicos en combinaciones de dosis fijas con paracetamol
dc.typeArtículo


Este ítem pertenece a la siguiente institución