Development and validation of a High Performance Liquid Chromatography-Diode Array Detection method for the determination of aging markers in tequila
dc.contributor | Mu�oz-Mu�oz, A.C., Centro de Investigacion y Asistencia en Tecnologia y Diseno del Estado de Jalisco, Av. Normalistas 800, 44270 Guadalajara, Jalisco, Mexico; Grenier, A.C., Peace Corps M�xico, Av. Universidad 202 Ote, 76020 Queretaro Queretaro,, Mexico; Guti�rrez-Pulido, H., Centro Universitario de Ciencias Exactas e Ingenier�as, Departamento de Matem�ticas, Universidad de Guadalajara, Corregidora 500, 44840 Guadalajara, Jalisco, Mexico; Cervantes-Mart�nez, J., Centro de Investigacion y Asistencia en Tecnologia y Diseno del Estado de Jalisco, Av. Normalistas 800, 44270 Guadalajara, Jalisco, Mexico | |
dc.creator | Munoz-Munoz, A.C. | |
dc.creator | Grenier, A.C. | |
dc.creator | Gutierrez-Pulido, H. | |
dc.creator | Cervantes-Martinez, J. | |
dc.date.accessioned | 2015-09-15T17:40:58Z | |
dc.date.accessioned | 2023-07-04T04:20:51Z | |
dc.date.available | 2015-09-15T17:40:58Z | |
dc.date.available | 2023-07-04T04:20:51Z | |
dc.date.created | 2015-09-15T17:40:58Z | |
dc.date.issued | 2008 | |
dc.identifier | http://www.scopus.com/inward/record.url?eid=2-s2.0-56249119517&partnerID=40&md5=74a71d48d3b61064f778848af8c8bb1f | |
dc.identifier | http://hdl.handle.net/20.500.12104/40592 | |
dc.identifier | 10.1016/j.chroma.2008.10.018 | |
dc.identifier.uri | https://repositorioslatinoamericanos.uchile.cl/handle/2250/7269370 | |
dc.description.abstract | A solid-phase extraction procedure followed by analysis by high performance liquid chromatography (HPLC) with UV-vis photodiode array detection (DAD) is proposed to simultaneously determine 11 aging markers in tequila. The method showed good intraday (n = 5) and interday (n = 3) precision, RSD < 1.6% in both cases, for each of the identified compounds. The calibration curves were linear at the tested ranges (R2 > 0.999). Good recoveries (84.2-108.5%) were obtained for 10 of the 11 compounds studied; and the LOD and LOQ ranged from 0.62 to 4.09 ?g/mL and 1.9-12.4 ?g/mL, respectively. The proposed methodology was applied to a set of 15 authentic tequila samples grouped by aging state (blanco, reposado and a�ejo). An ANOVA analysis combined with discriminant analysis with stepwise backward variable selection was used to differentiate between the various aging groups based on their oak related compounds content. � 2008 Elsevier B.V. All rights reserved. | |
dc.relation | Scopus | |
dc.relation | WOS | |
dc.relation | Journal of Chromatography A | |
dc.relation | 1213 | |
dc.relation | 2 | |
dc.relation | 218 | |
dc.relation | 223 | |
dc.title | Development and validation of a High Performance Liquid Chromatography-Diode Array Detection method for the determination of aging markers in tequila | |
dc.type | Article |