dc.contributorRamírez, J.J., Department of Orthopedics, Hospital Civil de Guadalajara, Fray Antonio Alcalde, Universidad de Guadalajara, Guadalajara, Mexico; Chiquete, E., Department of Internal Medicine, Hospital Civil de Guadalajara, Fray Antonio Alcalde, Universidad de Guadalajara, Guadalajara, Mexico; Ramírez, J.J., Universidad Autónoma de Guadalajara, Zapopan, Mexico; Gómez-Limón, E., Department of Neurology and Neurosurgery, Hospital Civil de Guadalajara, Fray Antonio Alcalde, Universidad de Guadalajara, Guadalajara, Mexico; Ramírez, J.M., Department of Internal Medicine, Hospital Civil de Guadalajara, Fray Antonio Alcalde, Universidad de Guadalajara, Guadalajara, Mexico
dc.creatorRamirez, J.J.
dc.creatorChiquete, E.
dc.creatorRamirez, J.J.
dc.creatorGomez-Limon, E.
dc.creatorRamirez, J.M.
dc.date.accessioned2015-11-18T23:43:41Z
dc.date.accessioned2023-07-04T04:15:38Z
dc.date.available2015-11-18T23:43:41Z
dc.date.available2023-07-04T04:15:38Z
dc.date.created2015-11-18T23:43:41Z
dc.date.issued2010
dc.identifierhttp://hdl.handle.net/20.500.12104/63226
dc.identifier10.1016/j.arcmed.2010.08.013
dc.identifierhttp://www.scopus.com/inward/record.url?eid=2-s2.0-78049449520&partnerID=40&md5=9fe37e63d34250056b270f4354db9660
dc.identifierhttp://ovidsp.ovid.com/ovidweb.cgi?T=JS&CSC=Y&NEWS=N&PAGE=fulltext&D=med5&AN=21044753
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/7269020
dc.description.abstractAn expandable vertebral body prosthesis with dual cage-and-plate function in a single device (JR prosthesis) was designed to test the hypothesis that this modular system can provide the biomechanical requirements for immediate and durable spine stabilization after corpectomy. Cadaver assays were performed with a stainless steal device to test fixation and adequacy to the human spine anatomy. Then, 14 patients with vertebral tumors (eight metastatic) underwent corpectomy and vertebral body replacement with a titanium-made JR prosthesis. All patients had neurological deficit, severe pain and spine instability prior to surgery. Mean pain score before surgery on a visual analog scale decreased from 7.6-3.0 points after operation (p = 0.002). All patients achieved at least one grade of improvement in the Frankel score (p = 0.003), excepting the three patients with Frankel grade A before surgery. Two patients with renal cell carcinoma died during the following 4 days after surgery. The remaining patients attained a painless and stable spine immediately, which was maintained for long periods (mean follow-up: 25.4 months). No significant infections or implant failures were registered. A nonfatal case of inferior vena cava surgical injury was observed (repaired during surgery without further complications). In conclusion, the JR prosthesis stabilizes the spine immediately after surgery and for the rest of the patients' life. To our knowledge, this is the first report on the clinical experience of any expandable vertebral body prosthesis with dual cage-and-plate function in a single device. © 2010 IMSS.
dc.relationArchives of Medical Research
dc.relation41
dc.relation6
dc.relation478
dc.relation482
dc.relationScopus
dc.relationWOS
dc.relationMEDLINE
dc.titleAn Expandable Prosthesis with Dual Cage-and-Plate Function in a Single Device for Vertebral Body Replacement: Clinical Experience on 14 Cases with Vertebral Tumors