dc.contributorBarbosa Parada, Nathaly
dc.creatorCely Segura, Erika Xiomara
dc.date.accessioned2022-10-18T13:37:21Z
dc.date.accessioned2023-06-06T22:53:05Z
dc.date.available2022-10-18T13:37:21Z
dc.date.available2023-06-06T22:53:05Z
dc.date.created2022-10-18T13:37:21Z
dc.date.issued2022
dc.identifierhttps://repositorio.unal.edu.co/handle/unal/82373
dc.identifierUniversidad Nacional de Colombia
dc.identifierRepositorio Institucional Universidad Nacional de Colombia
dc.identifierhttps://repositorio.unal.edu.co/
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/6650950
dc.description.abstractLas matrices de riesgo son herramientas empleadas para la implementación y uso de las evaluaciones del riesgo radiológico en practicas médicas e industriales que usen radiaciones ionizantes. El presente trabajo busca implementar esta metodología a una radiofarmacia de alta complejidad, partiendo de un análisis retrospectivo de incidentes reportados por la instalación, la búsqueda en la literatura y la observación de la instalación desde adentro, generando posibles escenarios en los cuales puedan ocurrir sucesos iniciadores de riesgo radiológico. Partiendo de estos escenarios de exposición, calculando dosis, relacionando estas con efectos tisulares y evaluando las funciones de seguridad de la instalación, se obtuvo que, al discriminar sobre quien recaen las consecuencias, el 65% se dieron sobre los trabajadores, 18% sobre el público y 17% sobre los pacientes. Para los trabajadores las dosis normales y potenciales con mayores contribuciones se dieron en dosi ficación de radiofármacos, dadas las exposiciones externas en manos durante esta tarea y la posible exposición interna por dosi ficación de 131I. Los incidentes asociados a ciclotrón con dosis externas a personal de socorro y las exposiciones externas e internas ante liberación de vertimientos líquidos por emergencias radiológicas son las mayores contribuciones al público. Después de ponderar el riesgo radiológico de los 109 sucesos indicadores, no se clasi ficó ninguno como riesgo alto o muy alto, aún contemplando los escenarios más complejos y de mayor riesgo. Los resultados arrojados y el análisis de estos, permiten concluir que las prácticas realizadas en el Servicio de Radiofarmacia y Ciclotrón del INC son seguras. (Texto tomado de la fuente)
dc.description.abstractRisk matrices are tools used for the implementation and use of radiological risk assessments in medical and industrial practices that use ionizing radiation. The present work seeks to implement this methodology to a highly complex radiopharmacy, based on a retrospective analysis of incidents reported by the facility, the literature search and the observation of the facility from the inside, to generate possible scenarios in which events may occur. radiological hazard initiators. Based on these exposure scenarios, calculating doses, relating them to tissue e ects and evaluating the safety functions of the facility, it was found that, when discriminating against who the consequences fall on, 65% occurred on the workers, 18% on the public and 17% on patients. For the workers, the normal and potential doses with the greatest contributions occurred in the dosage of radiopharmaceuticals, given the external exposures to the hands during this task and the possible internal exposure due to the preparation of 131I. Incidents associated with cyclotrons with external doses to rescue personnel and internal and external exposures due to the release of liquid discharges due to radiological emergencies are the greatest contributions to the public. After weighing the radiological risk of the 109 initiating events, none was classi ed as high or very high risk, even contemplating the most complex and highest risk scenarios, the results obtained allow us to conclude that the practices carried out in the radiopharmacy and cyclotron service of the INC are safe.
dc.languagespa
dc.publisherInstituto Nacional de Cancerología
dc.publisherUniversidad Nacional de Colombia
dc.publisherBogotá - Ciencias - Maestría en Física Médica
dc.publisherDepartamento de Física
dc.publisherFacultad de Ciencias
dc.publisherBogotá, Colombia
dc.publisherUniversidad Nacional de Colombia - Sede Bogotá
dc.relationOIEA, TECDOC-1685/S, Aplicaci on del m etodo de la matriz de riesgo a la radioterapia, Disponible en: https://www-pub.iaea.org/MTCD/Publications/PDF/TE_1685_S_CD/PDF/IAEA-TECDOC-1685.pdf.
dc.relationForo Iberoamericano de Organismos Reguladores y Nucleares, \SEVRRA". Disponible en: https://www.foroiberam.org/sevrra (Consultado en 2020).
dc.relationIAEA, Producción de radiofármacos. Disponible en: https://www.iaea.org/es/temas/produccion-de-radiofarmacos (Consultado en 2020).
dc.relationY. Chain, L. Illanes, Radiofármacos en medicina nuclear Fundamentos y aplicación cl nica, 2015, Disposible en: http://sedici.unlp.edu.ar/bitstream/handle/10915/46740/ Documento_completo.pdf?sequence=1.
dc.relationNTC 3970:1996, Transporte de mercanc as peligrosas Clase 7 Materiales radiactivos. Embalaje/envase y transporte. Disponible en: https://web.mintransporte.gov.co/consultas/mercapeli/Reglamento/Anexos/NTC3970.pdf.
dc.relationC Duménigo, M Guerrero, R López, A.B Paz,\MATRICES DE RIESGO EN MEDICINA NUCLEAR. MODELACIÓN EN SEVRRA" Proceedings XI Latin American IRPA Regional Congress on Radiation Protection and Safety -IRPA 2015,Buenos Aires, Argentina, 2015.
dc.relationResolución No. 4245 del 19 de Octubre del 2015, Ministerio de Salud y Protección Social. Disponible en: https://www.minenergia.gov.co/documents/10180//23517//21433-3684.pdf.
dc.relationGuías de procedimientos radiofarmacéuticos. Real Farmacopea Española, 1998-2004.
dc.relationResolución No. 90 874 del 11 de Agosto del 2014, Ministerio de Minas y Energía. Disponible en: https://www.minenergia.gov.co/documents/10180/23517/26138-Resolucion-9+0874-11Ago2014.pdf.
dc.relationResolución No. 18 1434 de Diciembre 5 de 2002, Ministerio de Minas y Energía. Disponible en: http://legal.legis.com.co/document/Index?obra=legcol&document=legcol_75992041d70cf034e0430a010151f034.
dc.rightsReconocimiento 4.0 Internacional
dc.rightshttp://creativecommons.org/licenses/by/4.0/
dc.rightsinfo:eu-repo/semantics/openAccess
dc.titleEvaluación del riesgo radiológico en la radiofarmacia de alta complejidad del Instituto Nacional de Cancerología: implementación de matrices de riesgo
dc.typeTrabajo de grado - Maestría


Este ítem pertenece a la siguiente institución