dc.description.abstractIntroduction: Recently, new techniques for cardiac arrhythmia ablation, such as contact force (CF) technology, have emerged. These catheters provide information about adequate tissue contact for an optimal lesion. In adults, these techniques have shown greater accuracy, reduced arrhythmia recurrence and complications, and higher success rates. However, data in pediatrics are limited. Objective: We aimed to describe the experience of arrhythmia ablation in the pediatric population with CF catheters. Methods: A retrospective cross-sectional descriptive study of all patients younger than 18 years of age undergoing cardiac 3D mapping and ablation with CF between March 2016 and June 2022 was performed. Results: A total of 321 patients were included (51.40% male with a mean age of 12.26 years). The most frequent arrhythmias included supraventricular tachycardia (SVT) mediated by accessory pathways (AP) [atrioventricular reentrant tachycardia (AVRT)] in 82.24%, ventricular arrhythmias (VA) in 11.21% and atrial tachycardia (AT) in 5.92%. The mean procedure time was 2.86 hours (sd 1.2), and the average contact used was 14.33 grams (sd 6.88). The success rate of ablation was 97.82% with a low risk of complications. Conclusion: This is the largest published series of patients under 18 years of age using CF technology. In the pediatric population, CF ablation is a safe procedure with high success rates and can be used for most arrhythmic substrates. The most frequent tachycardia observed in this study was SVT mediated by AP. Contact with 14 grams is safe and yields an excellent outcome in children. The presence of SHA and previous ablation procedures decreased the success rate.
dc.languageeng
dc.publisherUniversidad del Rosario
dc.publisherEscuela de Medicina y Ciencias de la Salud
dc.publisherEspecialización en Cardiología Pediátrica
dc.rightsinfo:eu-repo/semantics/embargoedAccess
dc.rightsRestringido (Temporalmente bloqueado)
dc.rightsEL AUTOR, manifiesta que la obra objeto de la presente autorización es original y la realizó sin violar o usurpar derechos de autor de terceros, por lo tanto la obra es de exclusiva autoría y tiene la titularidad sobre la misma. PARGRAFO: En caso de presentarse cualquier reclamación o acción por parte de un tercero en cuanto a los derechos de autor sobre la obra en cuestión, EL AUTOR, asumirá toda la responsabilidad, y saldrá en defensa de los derechos aquí autorizados; para todos los efectos la universidad actúa como un tercero de buena fe. EL AUTOR, autoriza a LA UNIVERSIDAD DEL ROSARIO, para que en los términos establecidos en la Ley 23 de 1982, Ley 44 de 1993, Decisión andina 351 de 1993, Decreto 460 de 1995 y demás normas generales sobre la materia, utilice y use la obra objeto de la presente autorización. -------------------------------------- POLITICA DE TRATAMIENTO DE DATOS PERSONALES. Declaro que autorizo previa y de forma informada el tratamiento de mis datos personales por parte de LA UNIVERSIDAD DEL ROSARIO para fines académicos y en aplicación de convenios con terceros o servicios conexos con actividades propias de la academia, con estricto cumplimiento de los principios de ley. Para el correcto ejercicio de mi derecho de habeas data cuento con la cuenta de correo habeasdata@urosario.edu.co, donde previa identificación podré solicitar la consulta, corrección y supresión de mis datos.
dc.rightshttp://creativecommons.org/licenses/by-nc-sa/2.5/co/
dc.rightsAtribución-NoComercial-SinDerivadas 2.5 Colombia
dc.sourceBrugada J, Hermosilla RM, Baranchuk A: Ablación por Catéter de Arritmias Cardíacas. [Internet]. CETIFAC - Bioingeniería UNER - Webmaster - HonCode. 2012,. Available from: http://www.fac.org.ar/1/publicaciones/libros/ablacion/capitulo1.php.
dc.sourceDalal AS, Nguyen HH, Bowman T, Van Hare GF, Avari Silva JN: Force-sensing catheters during pediatric radiofrequency ablation: The FEDERATION study. J Am Heart Assoc 2017; 6.
dc.sourceThomas PE, Macicek SL: Catheter ablation to treat supraventricular arrhythmia in children and adults with congenital heart disease: What we know and where we are going. Ochsner J 2016; 16:290–296.
dc.sourceCheng W, Yao M, Zhai B, Wang P: Contact force sensors in minimally invasive catheters: current and future applications. Expert Rev Med Devices [Internet] Taylor & Francis, 2021; 18:445–455. Available from: https://doi.org/10.1080/17434440.2021.1917372.
dc.sourceGulletta S, Vergara P, Gigli L, et al.: Usefulness of Electroanatomical Mapping with Contact Force Monitoring for Accessory Pathways Ablation in Pediatric Population. Pediatr Cardiol [Internet] Springer US, 2019; 40:713–718. Available from: http://dx.doi.org/10.1007/s00246-019-02051-0.
dc.sourceGuajardo S del CC: Universidad Complutense de Madrid Un. La teisis Dr en Teor y Empir [Internet] 2016; :1–55. Available from: https://core.ac.uk/download/pdf/33103547.pdf.
dc.sourceCorcia MCG, Stuart G, Walsh M, et al.: Redo accessory pathway ablation in the pediatric population. J Interv Card Electrophysiol [Internet] Springer US, 2022; 63:639–649. Available from: https://doi.org/10.1007/s10840-021-01064-1.
dc.sourcePook C, Kuhn E, Singh A, Kovach J: Contact force ablation of accessory pathways in pediatric patients. J Cardiovasc Electrophysiol 2021; 32:370–375.
dc.sourceVirk SA, Bennett RG, Trivic I, Campbell T, Kumar S: Contact Force and Ablation Index. Card Electrophysiol Clin [Internet] Elsevier Inc, 2019; 11:473–479. Available from: https://doi.org/10.1016/j.ccep.2019.05.007.
dc.sourceWalsh MA, Gonzalez CM, Uzun OJ, et al.: Outcomes From Pediatric Ablation: A Review of 20 Years of National Data. JACC Clin Electrophysiol 2021; 7:1358–1365.
dc.sourceAriyarathna N, Kumar S, Thomas SP, Stevenson WG, Michaud GF: Role of Contact Force Sensing in Catheter Ablation of Cardiac Arrhythmias: Evolution or History Repeating Itself? JACC Clin Electrophysiol 2018; 4:707–723.
dc.sourceKugler JD, Danford DA, Houston KA, Felix G: Pediatric Radiofrequency Catheter Ablation Registry success, fluoroscopy time, and complication rate for supraventricular tachycardia: Comparison of early and recent eras. J Cardiovasc Electrophysiol 2002; 13:336–341.
dc.sourceArujuna A, de Bono J. Maximizing the Effectiveness of Ablation for Arrhythmias in the Congenital Heart Patients. Curr Cardiol Rep. 2016 Jul;18(7):69. doi: 10.1007/s11886-016-0736-7. PMID: 27289368.
dc.sourceHouck CA, Chandler SF, Bogers AJJC, Triedman JK, Walsh EP, de Groot NMS, Abrams DJ. Arrhythmia Mechanisms and Outcomes of Ablation in Pediatric Patients With Congenital Heart Disease. Circ Arrhythm Electrophysiol. 2019 Nov;12(11):e007663. doi: 10.1161/CIRCEP.119.007663. Epub 2019 Nov 14. PMID: 31722541.
dc.sourceinstname:Universidad del Rosario
dc.sourcereponame:Repositorio Institucional EdocUR
dc.subjectAblación de arritmia cardíaca
dc.subjectFuerza de contacto
dc.subjectTaquicardia supraventricular
dc.subjectArritmia ventricular
dc.subjectTaquicardia auricular
dc.subjectCardiología pediátrica
dc.subjectVía accesoria
dc.titleUse of contact force technology for cardiac arrhythmia ablation in children