dc.creator | Cabrini N., Pavez C., Avaria G., Martin P.S., Veloso F., Soto L. | |
dc.creator | Zúñiga, Bárbara [Facultad de Ingeniería, Universidad Mayor, Chile] | |
dc.creator | Sepúlveda, Adolfo [Facultad de Ingeniería, Universidad Mayor, Chile] | |
dc.date.accessioned | 2020-08-12T14:11:55Z | |
dc.date.accessioned | 2020-08-12T19:30:37Z | |
dc.date.accessioned | 2022-10-18T18:42:19Z | |
dc.date.available | 2020-08-12T14:11:55Z | |
dc.date.available | 2020-08-12T19:30:37Z | |
dc.date.available | 2022-10-18T18:42:19Z | |
dc.date.created | 2020-08-12T14:11:55Z | |
dc.date.created | 2020-08-12T19:30:37Z | |
dc.date.issued | 2015 | |
dc.identifier | Cabrini, N., Pavez, C., Avaria, G., San Martin, P., Veloso, F., Zúñiga, B., ... & Soto, L. (2015, January). Wire array experiments in a low impedance and low current generator. In Journal of Physics: Conference Series (Vol. 591, No. 1, p. 012026). IOP Publishing Ltd.. | |
dc.identifier | https://iopscience.iop.org/article/10.1088/1742-6596/591/1/012026/pdf | |
dc.identifier | http://repositorio.umayor.cl/xmlui/handle/sibum/6952 | |
dc.identifier | DOI: 10.1088/1742-6596/591/1/012026 | |
dc.identifier.uri | https://repositorioslatinoamericanos.uchile.cl/handle/2250/4454789 | |
dc.description.abstract | In this work, a preliminary study about the behavior of a low impedance generator on different wire array configurations is reported. The experimental measurements were carried out on a small multi-purpose generator (1.2μF, 345J, 47.5nH, T/4 = 375 ns and Z = 0.2Ω in short circuit) which produces currents up to 122 kA with 500 ns quarter period, when a charging voltage of 24kV and a wire load are used. Two types of configurations were tested: parallel wires (two and four) and X-pinch configurations. The experiments were carried out on W, Al, and Cu wires with different diameters. The discharge was characterized by means of a set of diagnostics which included: Rogowski coil; filtered PCD detector; filtered PIN diode; gated VUV/soft X-ray pinhole camera, Shadow diagnostic and dark field Schlieren technique. From the set of experimental results, the following observations can be established: (i) The generator is highly sensitive to the changes of load impedance due to its low impedance design. (ii) Every shot shows a dip in the current derivative signal shortly after the discharge onset time (from 6 to 40 ns), which is inversely related to the load resistance. (iii) Both configurations show a similar dynamic to those observed in experiments of higher current and shorter quarter period. (iv) At the X-pinch experiments, two or more hard X-ray bursts are detected, around 200 ns from the current onset time. These X-ray bursts are correlated with the dips observed in the current derivative signal. | |
dc.language | en | |
dc.publisher | 15th Latin American Workshop on Plasma Physics (LAWPP 2014) and 21st IAEA TM on Research Using Small Fusion Devices (RUSFD) 27–31 January 2014, San José, Costa Rica | |
dc.rights | Attribution-NonCommercial-NoDerivs 3.0 Chile | |
dc.source | Journal of Physics: Conference Series, 2015. 591(1), ART. N° 12026 | |
dc.title | Wire array experiments in a low impedance and low current generator | |
dc.type | Artículos de revistas | |