info:eu-repo/semantics/article
IDA-PBC controller of a DC-DC boost converter for continuous and discontinuous conduction mode
Fecha
2018-01Registro en:
Serra, Federico Martin; Magaldi, Guillermo Luciano; Martín Fernández, Lucas Luciano; Larregay, Guillermo Omar; de Angelo, Cristian Hernan; IDA-PBC controller of a DC-DC boost converter for continuous and discontinuous conduction mode; Institute of Electrical and Electronics Engineers; IEEE Latin America Transactions; 16; 1; 1-2018; 52-58
1548-0992
CONICET Digital
CONICET
Autor
Serra, Federico Martin
Magaldi, Guillermo Luciano
Martín Fernández, Lucas Luciano
Larregay, Guillermo Omar
de Angelo, Cristian Hernan
Resumen
A passivity based non-linear control strategy to regulate the output voltage of a boost converter is proposed in this paper. The controller can work in both, continuous and discontinuous conduction mode. A modification in the classical averaged model of the converter is performed with the aim to include the discontinuous conduction mode operation condition. The control strategy is designed using Interconnection and Damping Assignment which ensures the stability of the closed loop system. The performance of the proposal is validated with simulations and experimental results.