dc.description.abstractAn automated panoramic irradiator with a 111 GBq (3 Ci) 241Am-Be neutron source is installed in a bunker-type large room (16.25 m long, 8.90 m width, 8 m high) at UPM. The irradiation bench is placed at 3 m from the floor and at about 4.5 m from any lateral wall. A neutron spectrometry campaign was organized with four groups participating with different Bonner Sphere Spectrometers (BSS) and using different spectral unfolding codes. The objective is to better characterize the facility, but also the intercomparison itself.
dc.languageeng
dc.publisherInternational Radiation Protection Association
dc.relationgeneralPublic
dc.rightshttp://creativecommons.org/licenses/by-nc-sa/3.0/us/
dc.rightsAtribución-NoComercial-CompartirIgual 3.0 Estados Unidos de América
dc.source13th International Congress of the International Radiation Protection Association (IRPA)
dc.titleCharacterization of an 241AmBe neutron irradiation facility by different spectrometric techniques