Universidad Autónoma de Zacatecas (México): últimos ingresos
Mostrando ítems 2421-2440 de 3065
-
NaI(Tl) Scintillator's Response Functions for Point-like and Distributed Gamma-ray Sources
(Chitkara University, 2016-08)The response functions of a NaI(Tl) detectors have been estimated using Monte Carlo methods. Response functions were calculated for monoenergetic photon sources (0.05 to 3 MeV). Responses were calculated for point-like ... -
Medición de K40 en Suelo de Mina
(Sociedad Mexicana de Seguridad RadiológicaSociedad Nuclear Mexicana, 2014-09)La radiactividad natural del suelo y la exposición externa de la radiación gamma dependen principalmente de las características geológicas del mismo. Sus niveles de radiactividad proporcionan información de la distribución ... -
GDR in Radiotherapy Treatment Fields with 18 MV Accelerators
(CERN, European Organization for Nuclear Research, 2015-06)Giant dipole photo-nuclear reactions generated during Linac radiotherapy are of concern due to the undesirable neutron dose delivered to patients. Nuclear track methodology provides an estimation of gradients of ... -
Evolutionary Artificial Neural Networks in Neutron Spectrometry
(IntechOpen, 2010-07)Artificial Neural Networks (ANN), are highly simplified models of the brain processes (Graupe, 2007; Kasabov, 1998). AnANNis a biologically inspired computational model which consists of a large number of simple processing ... -
Estudio de un detector de neutrones de centelleo de 10B+ZnS(Ag) como alternativa a los detectores de 3He: Modelo MCNPX y validación
(Universidad Autónoma Metropolitana, 2015-09)Mediante métodos Monte Carlo con el código MCNPX, se ha estimado la respuesta de un detector de neutrones de centelleo de ZnS(Ag) con un mezcla de 10B de alto enriquecimiento. El detector consiste en cuatro placas de ... -
Dosis en los Órganos Internos de una Embarazada Debida al I131 retenido en su Glándula Tiroides
(Asociación Mexicana de Envase y EmbalajeSociety of nuclear medicine, 2007-07)Se ha calculado la dosis absorbida por los órganos internos de una mujer con tres meses de embarazo, cuando su tiroides tiene I-131. El cálculo se realizó utilizando métodos Monte Carlo donde se diseño un modelo ... -
Studies on Neutron and Photon Kerma Parameters for Human Body Organs
(Nuclear Society of Serbia, 2016-06)A study on neu tron kerma fac tors and pho ton air-kerma for hu man or gans is pre sented for neu tron en ergy range 2.53 10–8 to 29 MeV and pho ton en ergy range 1 keV to 20 MeV. The human or gans wa ter equiv a lence for ... -
Detectores de Neutrones de 10B+ZnS(Ag) como alternativa a los detectores de 3He instalados en los Monitores de Radiación tipo Pórtico RPM’s
(Universidad Autónoma MetropolitanaCentro de Investigación y de Estudios Avanzados del Instituto Politécnico Nacional (CINVESTAV), 2016-11)Los sistemas de detección llamados “Radiation Portal Monitors” RPMs o Monitores de Radiación tipo Pórtico habitualmente instalados en zonas fronterizas, son un conjunto de detectores gamma y de neutrones; el uso de ... -
Detector de 10B+ZnS(Ag) para deteccion del trafico ilicito de SNM en aduanas, como alternativa a los detectores de 3He instalados en los RPM’s
(Sociedad Nuclear Española, 2016-09)En la Seguridad Nacional, una de las principales líneas de defensa contra el terrorismo nuclear en las fronteras, es el control de las mercancías y de las personas que entran y salen por las aduanas de cada país, con ... -
Photon and neutron shielding features of quarry tuff
(Elsevier, 2017)The shielding characteristics of quarry tuff (cantera) against photons and 241AmBe neutrons, were determined. The effective atomic number of cantera, the Exposure and the Energy absorption buildup factors for photons in ... -
Cálculo de la respuesta del detector
(Sociedad Argentina de Radioprotección, 2015-04)Mediante métodos Monte Carlo se ha estimado la respuesta de un detector de centelleo para neutrones. El detector consiste en 4 bloques de polimetil metacrilato (PMMA) (330 x 230 x 40 mm) en cuyas superficies de contacto ... -
Biological Activity and Implications of the Metalloproteinases in Diabetic Foot Ulcers
(IntechOpen, 2017-12)Inadequate metabolic control predisposes diabetic patient to a series of complications on account of diabetes mellitus (DM). Among the most common complications of DM is neuropathy, which causes microvascular damage by ... -
Brief Analysis of the Optical Behavior of Zns: Mn Nanocrystals
(Universidad Babeș-Bolyai, 2018-06-29)Depending on the particle size of the zinc sulfide (ZnS), some optical properties may change. In particular, the inclusion of manganese (Mn2+) as an impurity shows interesting optical properties, which has become a topic ... -
XV International Symposium on Solid State Dosimetry,
(Sociedad Química de México, 2006)Se utilizó la técnica de Análisis por Activación con Neutrones para determinar la concentración de elementos nocivos en fibras de polímero biocompatible con tejido óseo (BOP-F). Este material se emplea como sustituto cuando ... -
Análisis Monte Carlo del Laboratorio de Patrones Neutrónicos del CIEMAT
(Sociedad Mexicana de Seguridad RadiológicaSociedad Nuclear Mexicana, 2014-09)Mediante métodos Monte Carlo se ha caracterizado el campo de neutrones producido por fuentes de calibración en el laboratorio de Patrones Neutrónicos del Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas. ... -
Absorbed Dose in the Uterus of a Three Months Pregnant Woman Due to 131I
(AIP Publishing, 2006-10)The use of 131I is widely used in diagnostic and treatment of patients. If the patient is pregnant the 131I presence in the thyroid it becomes a source of constant exposition to other organs and the fetus. In this study ... -
Studies on neutron and photon KERMA parameters for human body organs
(Vinča Institute of Nuclear Sciences, 2016)A study on neu tron kerma fac tors and pho ton air-kerma for hu man or gans is pre sented for neu tron en ergy range 2.53×10–8 to 29 MeV and pho ton en ergy range 1 keV to 20 MeV. The human or gans wa ter equiv a lence ... -
Photon attenuation properties of some Thorium, Uranium and Plutonium compounds
(Universidad de Guanajuato, 2015-09)Mass attenuation coefficients, effective atomic numbers, effective electron densities for nuclear materials; thorium, uranium and plutonium compounds have been studied. The photon attenuation properties for the compounds ... -
Characterization of an 241AmBe neutron irradiation facility by different spectrometric techniques
(International Radiation Protection Association, 2012-05)An automated panoramic irradiator with a 111 GBq (3 Ci) 241Am-Be neutron source is installed in a bunker-type large room (16.25 m long, 8.90 m width, 8 m high) at UPM. The irradiation bench is placed at 3 m from the ... -
Design of a treatment room for an 18-MV LINAC
(Taylor & Francis, 2011-07)This work studies the design of the treatment room for an 18-MV linac to ensure radiation protection and safety of hospital staff and patients. The walls’ thickness, the door, and the maze were designed according to ...