dc.creatorDE LA CRUZ MORALES, KARLA; 817447
dc.creatorGOMEZ HERNANDEZ, MARTIN; 123149
dc.creatorHurtado y de la Peña, Marcela;#0000-0003-3546-5986
dc.creatorMedina-López, José Raúl;#0000-0002-4159-8403
dc.creatorALARCON ANGELES, GEORGINA; 161741
dc.creatorDe la Cruz Morales, Karla
dc.creatorGómez Hernández, Martín
dc.creatorHurtado y de la Peña, Marcela
dc.creatorMedina López, José Raúl
dc.creatorAlarcón Ángeles, Georgina
dc.date.accessioned2022-02-03T21:49:10Z
dc.date.accessioned2022-10-14T13:48:03Z
dc.date.available2022-02-03T21:49:10Z
dc.date.available2022-10-14T13:48:03Z
dc.date.created2022-02-03T21:49:10Z
dc.date.issued2017
dc.identifierhttp://hdl.handle.net/11191/8416
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/4238917
dc.description.abstractLa voltamperometría cíclica (VC) y voltamperometría diferencial de pulso (VDP) se usaron para caracterizar electroquímicamente la guanina y adenina usando un electrodo de carbón vítreo (GCE). En este trabajo se propone cuantificar la cantidad de guanina y adenina basados en una curva de calibración, previo a la cuantificación se analiza el comportamiento electroquímico de las bases a través de VC. A partir de este estudio se encontró que el rango de concentración lineal de adenina fue de 2-28 μM cuyo límite de detección (LD) y cuantificación (LC) determinado fue de 1.54 ±0.18 μM y 5.12 ±0.183 μM, respectivamente, con una sensibilidad de 0.1673 μAV-¹, mientras que para guanina, el rango de concentración lineal fue de 1-30 μM con un LD y LC de 1.64 ± 0.27 μM y 5.22 ± 0.274 μM, respectivamente, con una sensibilidad de 0.15 μAV-¹. Se reporta una metodología sencilla y reproducible para cuantificar las bases púricas del ácido desoxirribonucleico (ADN).
dc.description.abstractCyclic voltammetry (CV) and differential pulse voltammetry (DPV) were used to electrochemically characterize guanine and adenine behaviour using a glassy carbon electrode (GCE). In this work, we aim to quantify the amount of guanine and adenine based on a calibration curve. Before quantification, we study electrochemical behaviour of both purine bases using CV. The analyzed linear range of adenine was 2-28 μM, obtaining a limit of detection (LOD) and quantification (LOQ) of 1.54 ±0.18 μM and 5.12 ±0.183 μM, respectively, as well as a sensitivity of 0.1673 μAV-¹. For guanine, the linear range was 1-30 μM with a LOD and LOQ of 1.64 ± 0.27 μM, and 5.22 ± 0.274 μM, respectively, as well as a sensitivity of 0.15 μAV-¹. We report a simple and reproducible methodology to quantify purine bases of DNA.
dc.languagespa
dc.publisherUniversidad Autónoma Metropolitana (México). Unidad Azcapotzalco. División de Ciencias Básicas e Ingeniería.
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/4.0
dc.rightsopenAccess
dc.rightsAtribución-NoComercial-SinDerivadas
dc.sourceRevista Tendencias en Docencia e Investigación en Química. Año 3, número 3 (enero-diciembre de 2017). ISSN: 2448-6663
dc.subjectElectrodo de carbón vítreo, cuantificación, bases púricas del ADN. Glassy carbon electrode, quantification, purine bases of DNA.
dc.titleCaracterización y cuantificación electroquímica de las bases púricas de ADN sobre un electrodo de carbón vítreo
dc.typeArtículo


Este ítem pertenece a la siguiente institución