dc.description.abstractEn las regiones de clima cálido seco en México se ha extendido el uso de equipos de enfriamiento evaporativo directo que consumen altas cantidades de energía y agua, de ahí la necesidad de desarrollar un proyecto experimental con estrategias conservativas y bioclimáticas puestas en práctica en viviendas mínimas provistas de ese tipo de equipos en la ciudad de Chihuahua, México, a fin de reducir en lo posible su tiempo de operación. Las estrategias aplicadas fueron: instalación de termostato para control de encendido del equipo de enfriamiento evaporativo directo; aislamiento térmico adicional en cubierta; protección solar en ventanas; aislamiento térmico y protección solar del equipo de enfriamiento evaporativo directo; incremento de masa térmica en muros; y ventilación nocturna superpuesta a las anteriores. Se presentan los resultados en términos de ahorro de agua y energía y los beneficios asociados al ahorro de energía y de agua, con una perspectiva de ciclo de vida.
dc.description.abstractThe use of direct evaporative cooling in dry hot regions in Mexico is extensive with the consequent high consume of power and water. Therefor an experimental project was conducted in which six conservative and bioclimatic strategies were incorporated to low-cost housings conditioned with direct evaporative cooling, to reduce as possible its operation periods. The applied strategies in housing units in the city of Chihuahua, were: installation of a thermostatic control; additional thermal insulation on the roof; solar protection for windows; thermal insulation and solar protection of the direct evaporative cooling equipment; increase of thermal mass of walls; and night ventilation which were overlapped with all the previous options. In this paper, the results about power and water savings are presented, in addition, the economic consequences associated with these conservative and bioclimatic measures are analyzed, considering the additional costs required for their installation and operation, and the benefits associated with the savings of energy and water, using the life cycle cost method.
dc.languagespa
dc.publisherUniversidad Autónoma Metropolitana (México). Unidad Azcapotzalco.
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/4.0
dc.rightsopenAccess
dc.rightsAtribución-NoComercial-SinDerivadas
dc.sourceHábitat sustentable III (ISBN: 978-607-28-1753-1).
dc.subjectEnfriamiento evaporativo; estrategias de bioclimatización; costo de ciclo de vida; evaporative cooling; bioclimatic strategies; life cicle cost.
dc.titleCosto y rentabilidad de diversas estrategias bioclimáticas en viviendas con enfriamiento evaporativo directo en función del ciclo de vida