dc.creatorFLORES VALVERDE, ERASMO; 371257
dc.creatorVALLADARES RODRIGUEZ, MARIA RITA; 340161
dc.creatorGuillén Gómez, Luz Rubí
dc.creatorFlores Valverde, Erasmo
dc.creatorValladares Rodriguez, Maria Rita
dc.creatorGuillén Gómez, Luz Rubí
dc.date.accessioned2021-12-14T00:41:26Z
dc.date.accessioned2022-10-14T13:45:04Z
dc.date.available2021-12-14T00:41:26Z
dc.date.available2022-10-14T13:45:04Z
dc.date.created2021-12-14T00:41:26Z
dc.date.issued2018
dc.identifierhttp://hdl.handle.net/11191/8217
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/4238103
dc.description.abstractLa presente investigación aborda el tratamiento de aguas grises, en este caso las constituidas por aguas usadas en: lavabos, lavadoras y agua de aseo personal, se construyeron dos prototipos en el laboratorio, uno para el proceso aerobio y otro para el tratamiento en humedal artificial, en el tratamiento aerobio el oxígeno disuelto nunca fue menor de 5 mg/L, en el humedal se cultivaron vegetales conocidos comúnmente como: anturio, cuna de Moisés y linaza. Se corrieron diez experimentos seguidos uno de otro con tiempos de proceso de 24 y 48 horas, en cada una de las corridas se determinaron los siguientes parámetros: grasas y aceites, sólidos suspendidos, sólidos sedimentables, DBO, SAAM, O₂, temperatura y pH y coliformes fecales. Algunos parámetros mencionados sirvieron para evaluar la remoción de contaminantes del agua, basándose en lo establecido en las normas NOM-002-SEMARNAT-1996 y la NOM-003- SEMARNAT-2000, cuyos límites máximos permisibles se utilizaron para hacer la comparación de la calidad del agua cruda y la del agua tratada.
dc.description.abstractThe present investigation approaches the treatment of greywater in this case those constituted by waters used in: washbasin, washing machines and personal hygiene water. Two prototypes were built at the laboratory level, one for the aerobic process and the other for the treatment in artificial wetland, in the aerobic treatment the dissolved oxygen was never less than 5 mg / L, in the wetland vegetables commonly known as: anthurium were cultivated, cradle of Mases and linen. Ten experiments followed each other with process times of 24 and 48 hours, in each of the times the following parameters were determined: fats and oils, suspended solids, settleable solids, BOD, SAAM, O₂, temperature and pH and fecal coliforms. Sorne parameters mentioned served to evaluate the removal ofpollutants from the water in treatment, the normsNOM-002- SEMARNAT-1996 and NOM-003-SEMARNAT-2000 were used to make the comparison of the quality of the raw water and that of the treated water
dc.languagespa
dc.publisherUniversidad Autónoma Metropolitana (México). Unidad Azcapotzalco. División de Ciencias Básicas e Ingeniería.
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/4.0
dc.rightsopenAccess
dc.rightsAtribución-NoComercial-SinDerivadas
dc.sourceRevista Tendencias en Docencia e Investigación en Química. Año 4, número 4 (enero-diciembre de 2018). ISSN: 2448-6663
dc.subjectProceso, aerobio, humedal, agua tratada. Process, aerobic, wetland, treated water.
dc.titleTratamiento de aguas grises mediante procesos combinados: aerobio humedal