info:eu-repo/semantics/article
Diagnostic of nonceramic insulators aged in a salt fog chamber by using electric field sensor
Autor
RAMIRO HERNANDEZ CORONA
ISAIAS RAMIREZ VAZQUEZ
JOSE GERARDO MONTOYA TENA
Institución
Resumen
The objective of this paper is to validate the electric
field measurement technique for the diagnosis of uon-ceramic
insulators (NCI). To validate this technique, fifteen NCI were
aged in a salt fog chamber by applying uon-staudard methods.
Before ageing the NCI, the electric field distribution aloug each
insulator was measured (sound field curve). When an insulator
flashed over during the ageing test, the insulator was removed
from the salt fog chamber and its electric field distribution was
again measured (aged field curve). AU the insulators that flashed
over had visible defects and showed an electric field distribution
different to that initially Obtained. The comparison between the
sound field and aged field curves for these insulators validated
the location of the defects along the insulator. On the other
hand, the electric field distribution measured on insulators
which had no visible defects was similar to that initially
obtained. This means that for these cases the flashover was only
caused by the pollution phenomenon, and not by any defect
Furthermore, the electric field distribution measurements on all
the insulators at the middle and at the end of the ageing test
were performed, in order to mainly determine if some internal
defect in the insulators, without visible defects, had occurred