dc.contributor | Múnera Ramirez, Marcela Cristina | |
dc.contributor | Cifuentes García, Carlos Andrés | |
dc.creator | Rodríguez García, Nicolás | |
dc.date.accessioned | 2020-03-16T19:41:17Z | |
dc.date.accessioned | 2022-09-22T14:07:08Z | |
dc.date.available | 2020-03-16T19:41:17Z | |
dc.date.available | 2022-09-22T14:07:08Z | |
dc.date.created | 2020-03-16T19:41:17Z | |
dc.identifier | https://repository.urosario.edu.co/handle/10336/21017 | |
dc.identifier | https://doi.org/10.48713/10336_21017 | |
dc.identifier.uri | http://repositorioslatinoamericanos.uchile.cl/handle/2250/3435972 | |
dc.description.abstract | Over the past two decades, various orthoses and exoskeletons have been developed to improve the walking patterns of people affected by diseases related to cerebrovascular accident (CVA), a stroke happens when blood flow to part of the brain it stops. The active T-Flex orthosis is focused on ankle rehabilitation, and is aimed at people who have a pathology that limits the mobility of this joint, such as stroke, cerebral palsy or spinal cord injuries. For this the T-Flex has two modes of operation,; (1) the therapy mode where the user is sitting and the T-Flex performs dorsiflexion and plantarflexion movements at the speed and degree of movement required; (2) the gait mode, where the user can walk with the T-Flex and the T-Flex detects the gait phase by means of a sensor to perform dorsiflexion and plantarflexion movements according to the user's movement. In the context of this project, we want to improve the ergonomics of the physical interface system of the orthosis. That is, it seeks to improve the part of the orthosis in contact with the user, through different materials and soft surfaces. This improvement is proposed in order to make the orthosis as comfortable as possible for use during rehabilitation therapy or even for use in activities of daily living. The previous physical interface dissipated the force in shear stress, compression and generated a misalignment on the body, which caused the device to not work correctly and could generate user discomfort. In order to improve the physical interfaces, a review was first made of different materials that met certain criteria such as being light, soft, inexpensive and easy to handle. These features were sought in order to improve key aspects of the interface such as size, weight, and low grip. The chosen material was flexible polyurethane, a foam that is prepared from a base and a catalyst. By varying the proportion of these components, different densities can be obtained according to the percentages used in the mixture to obtain the material, that is, by increasing or decreasing the proportion of the catalyst, different densities of the polyurethane are achieved. Once the material was chosen, having reviewed the selection criteria detailed in the document, we proceeded to make different physical interfaces with said material, each interface consisting of a pair of foams that are located in the front (anterior tibial) and in the back (gastrocnemius) of the leg, as these are the parts where the T-Flex is in contact with the user. As for flexible polyurethane, different thicknesses were made from 2cm to 4cm and with different densities 60% -40% to 80% -20%. These proportions are chosen because they are easier to obtain since a very high density would create a too rigid polyurethane foam and a very low density would make a highly flexible polyurethane foam making it not maintain its shape or be used in the application. of this degree work. In this way 9 physical interfaces are obtained, for each thickness 3 different densities, in order to test which were effective and which was the most ergonomic in terms of comfort. Finally, the interfaces were covered with sports fabric and a Dragon SkinTM silicone was applied to this, in order to improve the adherence of the T-Flex to the user. To evaluate the proposed interfaces, a test was first performed with the therapy mode for 5 minutes, at medium speed and with a normal range of motion, where each of the 9 interfaces was tested on 10 healthy volunteers. The purpose of this test is to observe if the interface is displaced with respect to its initial position, if it presents an offset of more than 2cm it is considered not effective. In this test, only 7 interfaces were considered effective, so test 2 was performed with these. For the second test, the volunteers had to walk with the T-Flex for 5 minutes in an endless band, while measuring the EMG in the muscles in contact with the interface, the medial gastrocnemius and the tibialis anterior. In turn, the space-time parameters of the gait were also measured, such as cadence, gait speed and stride length using the G-Walk device. After 5 minutes the final displacement of the interface was measured, comparing the initial position of the interface versus the final position of the interface at the end of the test. Finally, each volunteer had to answer a questionnaire based on the Comfort Rating Scales, in order to determine which was the most comfortable interface for the majority of volunteers. Finally, after performing the tests and analyzing the results, it was determined that the best interfaces were the thickest, since this feature helps the interface to put more pressure on the users' legs and thus guarantee that the device do not slip or move during use. As can be seen in the results, these interfaces generate a lower workload. Regarding the parameters of the G-Walk, the average of the cadence and stride length was closer to the normal ranges. Regarding the displacement measurements, the 4cm interface with 80% -20% density is the one with the smallest displacement, being 0.2cm only in one test. With the questionnaire, it was confirmed that the thickest interfaces were the ones with the best evaluations. With all these results it is not possible to determine which of the 4cm thick interfaces is the best interface to use, since all the 4cm thick interfaces functioned as expected and adequately. | |
dc.language | spa | |
dc.publisher | Universidad del Rosario | |
dc.publisher | Ingeniería Biomédica | |
dc.publisher | Escuela de Medicina y Ciencias de la Salud | |
dc.rights | http://creativecommons.org/licenses/by-nc-sa/2.5/co/ | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights | Abierto (Texto Completo) | |
dc.rights | EL AUTOR, manifiesta que la obra objeto de la presente autorización es original y la realizó sin violar o usurpar derechos de autor de terceros, por lo tanto la obra es de exclusiva autoría y tiene la titularidad sobre la misma. | |
dc.rights | Atribución-NoComercial-CompartirIgual 2.5 Colombia | |
dc.source | D. M. Center, Body and Movement – The Importance of Body Movement, Fitness and Exercise, urlhttps://www.denvermovementcenter.com/blog/2016/11/27/bodyand- movement-the-importance-of-body-movement-fitness-and-exercise, 2016. (visitado 27-11-2016). | |
dc.source | M. F. for Medical Education y Research, Movement disorders, urlwww.mayoclinic.org/diseasesconditions/ movement-disorders/symptoms-causes/syc-20363893, 2017. (visitado 19-10-2017). | |
dc.source | U. N. L. of Medicine, Enfermedades neuromusculares, urlmedlineplus.gov/spanish/neuromusculardisorders. html, 2019. (visitado 29-01-2019). | |
dc.source | M. Munoz Collazos, «Enfermedades cerebrovasculares (ECV)», es, Acta Neurológica Colombiana, vol. 26, págs. 59-61, jun. de 2010, issn: 0120-8748. | |
dc.source | M. F. for Medical Education y Research, Accidente Cerebrovascular, urlmedlineplus. gov/spanish/ency/article/000726.htm, 2019. (visitado 06-11-2019). | |
dc.source | L. R. Sharer, «Modern Surgical Neuropathology», Journal of Neuropathology Experimental Neurology, vol. 68, n.o 11, págs. 686-704, nov. de 2009, issn: 0022-3069. doi: 10.1097/01.JNEN.0000363267.74552.c6. eprint: http://oup.prod.sis.lan/jnen/ article-pdf/68/11/1247/9558983/68-11-1247a.pdf. | |
dc.source | M. F. for Medical Education y Research, Ataque isquemico transitorio, urlmedlineplus. gov/spanish/transientischemicattack.html, 2019. (visitado 06-11-2019). | |
dc.source | P. Langhorne, J. Bernhardt y G. Kwakkel, «Stroke rehabilitation», The Lancet, vol. 377, n.o 9778, págs. 1693-1702, 2011. | |
dc.source | B. H. Dobkin, «Strategies for stroke rehabilitation», The Lancet Neurology, vol. 3, n.o 9, págs. 528-536, 2004. | |
dc.source | M. V. Garcés-Vieira y J. C. Suárez-Escudero, «Neuroplasticidad: aspectos bioquímicos y neurofisiológicos», Ces Medicina, vol. 28, n.o 1, págs. 119-131, 2014. | |
dc.source | Departamento, Administrativo y N. de Estadistica, Estadisticas de salud y discapacidad, url https://www.dane.gov.co/index.php/estadisticas-por-tema/salud/discapacidad, 2008. (visitado 20-06-2008). | |
dc.source | W. A. Satariano, J. M. Guralnik, R. J. Jackson, R. A. Marottoli, E. A. Phelan y T. R. Prohaska, «Mobility and aging: new directions for public health action.», American journal of public health, vol. 102 8, págs. 1508-15, 2012. | |
dc.source | C. for Disease Control y P. (CDC)., «Prevalence and most common causes of disability among adults–United States, 2005.», MMWR Morb Mortal Wkly Rep., vol. 16, n.o 48, págs. 421-426, 2009. | |
dc.source | U. Nations, World Population Ageing, urlwww.un.org/en/development/desa/population/ publications/pdf/ageing/WPA2017Highlights.pdf, 2017. (visitado 01-01-2017). | |
dc.source | L. Plouffe y A. Kalache, «Towards Global Age-Friendly Cities: Determining Urban Features that Promote Active Aging», Journal of urban health : bulletin of the New York Academy of Medicine, vol. 87, págs. 733-739, sep. de 2010. doi: 10.1007/s11524-010- 9466-0. | |
dc.source | T. I. S. Center, Stroke Statistics, urlhttp://www.strokecenter.org/patients/aboutstroke/ stroke-statistics/, 2011. (visitado 23-08-2011). | |
dc.source | D. Smith, E. Goldenberg, A. Ashburn, G. Kinsella, K. Sheikh, P. Brennan, T. Meade, D. Zutshi, J. Perry y J. Reeback, «Remedial therapy after stroke: A randomised controlled trial», British medical journal (Clinical research ed.), vol. 282, págs. 517-20, mar. de 1981. doi: 10.1136/bmj.282.6263.517. | |
dc.source | M. Dam, P. Tonin, A. S.Casson y et al., «The effects of long-term rehabilitation therapy on poststroke hemiplegic patients», Stroke, vol. 24, n.o 8, págs. 1186-1191, 1993. | |
dc.source | M. Shaughnessy, K. Michael, J. Sorkin y R. Macko, «Steps After Stroke: Capturing Ambulatory Recovery», Stroke; a journal of cerebral circulation, vol. 36, págs. 1305-7, jul. de 2005. doi: 10.1161/01.STR.0000166202.00669.d2. | |
dc.source | N. H. S. UK, Foot drop, url https://www.nhs.uk/conditions/foot-drop/, 2019. (visitado 20-02-2019). | |
dc.source | O. A. Government, Robotic-assisted rehabilitation devices: A wearable hand/finger rehabilitation robot, urlhttps://www.openaccessgovernment.org/robotic-assistedrehabilitation- devices/63018/, 2019. (visitado 10-04-2019). | |
dc.source | K. Wu, «Foot Orthoses: Principles and Clinical Applications», JPO Journal of Prosthetics and Orthotics, vol. 2, 1990. | |
dc.source | S. Mulroy, V. Eberly, J. Gronely, W. Weiss y C. Newsam, «Effect of AFO Design on Walking after Stroke: Impact of Ankle Plantar Flexion Contracture», Prosthetics and orthotics international, vol. 34, págs. 277-92, sep. de 2010. doi: 10.3109/03093646. 2010.501512. | |
dc.source | W. G. Janssen, H. B. Bussmann y H. J. Stam, «Determinants of the Sit-to-Stand Movement: A Review», Physical Therapy, vol. 82, n.o 9, págs. 866-879, sep. de 2002, issn: 0031-9023. doi: 10.1093/ptj/82.9.866. eprint: http://oup.prod.sis.lan/ptj/ article-pdf/82/9/866/9436423/ptj0866.pdf. | |
dc.source | A. Dogan, M. Mengüllüoglu y N. Özgirgin, «Evaluation of the effect of ankle-foot orthosis use on balance and mobility in hemiparetic stroke patients», Disability and rehabilitation, vol. 33, págs. 1433-9, nov. de 2010. doi: 10.3109/09638288.2010.533243. | |
dc.source | M. M. et al., «T-FLEX: Variable Stiffness Ankle-Foot Orthosis for Gait Assistance.», en Wearable Robotics: Challenges and Trends., M. C. Carrozza, S. Micera y J. L. Pons, eds., vol. 22, Biosystems Biorobotics, 2018, págs. 160-164. | |
dc.source | P. Buckle, P. Clarkson, R. Coleman, J. Ward y J. Anderson, «Patient safety, systems design and ergonomics», Applied ergonomics, vol. 37, págs. 491-500, ago. de 2006. doi: 10.1016/j.apergo.2006.04.016. | |
dc.source | J. Martin, B. Norris, E. Murphy y J. Crowe, «Medical Device Development: the challenge for ergonomics», Applied ergonomics, vol. 39, págs. 271-83, jun. de 2008. doi: 10.1016/ j.apergo.2007.10.002. | |
dc.source | J. Pons, R. Ceres y L. Calderón, «Introduction to Wearable Robotics», en. mar. de 2008, págs. 1-16, isbn: 9780470987667. doi: 10.1002/9780470987667.ch1. | |
dc.source | L. Valera, «Wearable Robots in rehabilitative therapy: A step towards transhumanism or an ecological support?», Filosofia Unisinos, vol. 17, págs. 105-110, ago. de 2016. doi: 10.4013/fsu.2016.172.03. | |
dc.source | K. Anam y A. Al-Jumaily, «Active Exoskeleton Control Systems: State of the Art», Procedia Engineering, vol. 41, págs. 988-994, dic. de 2012. doi: 10.1016/j.proeng. 2012.07.273. | |
dc.source | J. Perry, J. Rosen y S. Burns, «Upper-Limb Powered Exoskeleton Design», Mechatronics, IEEE/ASME Transactions on, vol. 12, págs. 408-417, sep. de 2007. doi: 10.1109/ TMECH.2007.901934. | |
dc.source | T. P. Company, About actuators, urlhttps://www.thomasnet.com/products/actuators- 301168-1.html, 2016. (visitado 26-04-2016). | |
dc.source | O. Sánchez-Flores, O. Sandoval-Gonzalez, J. Flores Cuautle, I. Herrera Aguilar y G. Rodríguez, «Diseño de un exoesqueleto bípedo para la asistencia de personas con debilidad en el sistema locomotor», oct. de 2015. | |
dc.source | L. R., J. Torres y S. Salazar, «Desarrollo de un exoesqueleto para rehabilitación de tobillo y rodilla», es, Revista mexicana de ingeniería biomédica, vol. 35, págs. 13-28, ene. de 2014, issn: 0188-9532. | |
dc.source | S. Galle, «Experimental optimization of an ankle-foot exoskeleton to reduce the metabolic cost of walking for practical applications in healthy and impaired subjects», Tesis doct., oct. de 2015. | |
dc.source | M. Looze, T. Bosch, F. Krause, K. Stadler y L. O’Sullivan, «Exoskeletons for industrial application and their potential effects on physical work load», Ergonomics, vol. 59, págs. 1-11, oct. de 2015. doi: 10.1080/00140139.2015.1081988. | |
dc.source | S. Zaroodny, «Bumpusher—A Powered Aid to Locomotion», ”. U.S. Army Ballistic Res. Lab, oct. de 1963. | |
dc.source | A. Dollar y H. Herr, «Herr, H.: Lower Extremity Exoskeletons and Active Orthoses: Challenges and State-of-the-Art. IEEE Transactions on Robotics 24(1), 144-158», Robotics, IEEE Transactions on, vol. 24, págs. 144-158, mar. de 2008. doi: 10.1109/TRO. 2008.915453. | |
dc.source | H. Yan y C. Yang, «Design and validation of a lower limb exoskeleton employing the recumbent cycling modality for post-stroke rehabilitation», Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science, vol. 228, págs. 3517-3525, nov. de 2014. doi: 10.1177/0954406214527578. | |
dc.source | B. Hu, H. Yu, H. Lu e Y. Chang, «Design of Mechanism and Control System for a Lightweight Lower Limb Exoskeleton», en 2018 3rd International Conference on Control, Robotics and Cybernetics (CRC), sep. de 2018, págs. 83-87. doi: 10.1109/ CRC.2018.00025. | |
dc.source | R. Robotics, ReWalk Personal, urlhttps://rewalk.com/rewalk-personal-3/, 2019. (visitado 03-03-2019). | |
dc.source | E. Strickland, «Good-bye, wheelchair», IEEE Spectrum, vol. 49, n.o 1, págs. 30-32, ene. de 2012. doi: 10.1109/MSPEC.2012.6117830. | |
dc.source | I. O. for Standardization, Prosthetics and Orthotics - Vocabulary. General terms for external limb prostheses and orthoses. urlhttps://www.iso.org/obp/ui/iso:std:iso:8549:- 1:ed-1:v1:en, 1989. (visitado 01-01-2007). | |
dc.source | M. Arazpour, M. Bani, S. Hutchins y R. Jones, «The physiological cost index of walking with mechanical and powered gait orthosis in patients with spinal cord injury», Spinal cord, vol. 51, dic. de 2012. doi: 10.1038/sc.2012.162. | |
dc.source | G. Cobb, Walking Motion, 1935. | |
dc.source | F. Menotti, L. Laudani, A. Damiani, P. Orlando y A. Macaluso, «Comparison of walking energy cost between an anterior and a posterior Ankle-Foot Orthosis (AFOs) in patients with foot drop», Journal of Rehabilitation Medicine, vol. 46, págs. 768-772, jun. de 2014. doi: 10.2340/16501977-1837. | |
dc.source | J. Blaya y H. Herr, «Adaptive Control of a Variable-Impedance Ankle-Foot Orthosis to Assist Drop-Foot Gait», IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society, vol. 12, págs. 24-31, abr. de 2004. doi: 10.1109/TNSRE.2003.823266. | |
dc.source | G. Sawicki y D. Ferris, «A pneumatically powered knee-ankle-foot orthosis (KAFO) with myoelectric activation and inhibition», Journal of neuroengineering and rehabilitation, vol. 6, pág. 23, jul. de 2009. doi: 10.1186/1743-0003-6-23. | |
dc.source | K. H. Low, Robot-assisted gait rehabilitation: From exoskeletons to gait systems. ago. de 2011, págs. 1-10. doi: 10.1109/DSR.2011.6026886. | |
dc.source | J. Figueiredo, C. P. Santos y J. C. Moreno, Assistance and rehabilitation of gait disorders using active lower limb orthoses. feb. de 2015, págs. 1-6. doi: 10.1109/ENBENG.2015. 7088837. | |
dc.source | H. Ring, I. Treger, L. Gruendlinger y J. Hausdorff, «Neuroprosthesis for Footdrop Compared with an Ankle-Foot Orthosis: Effects on Postural Control during Walking», Journal of stroke and cerebrovascular diseases : the official journal of National Stroke Association, vol. 18, págs. 41-7, ene. de 2009. doi: 10.1016/j.jstrokecerebrovasdis. 2008.08.006. | |
dc.source | P. Kluding, K. Dunning, M. O’Dell, S. Wu, J. Ginosian, J. Feld y K. Mcbride, «Foot Drop Stimulation Versus Ankle Foot Orthosis After Stroke 30-Week Outcomes», Stroke; a journal of cerebral circulation, vol. 44, mayo de 2013. doi: 10.1161/STROKEAHA.111. 000334. | |
dc.source | G. Xu, Y. Lan y Q. Zhang, «Effect of AFO on gait stability and balance control in patients with hemiparetic stroke», Annals of Physical and Rehabilitation Medicine, vol. 57, e21-e22, mayo de 2014. doi: 10.1016/j.rehab.2014.03.075. | |
dc.source | S. Yamamoto, M. Ebina, M. Iwasaki, S. Kubo, H. Kawai y T. Hayashi, «Comparative Study of Mechanical Characteristics of Plastic AFOs», 1993. | |
dc.source | L. Wang y F. Iida, «Deformation in Soft-Matter Robotics: A Categorization and Quantitative Characterization», IEEE Robotics Automation Magazine, vol. 22, n.o 3, págs. 125-139, sep. de 2015. doi: 10.1109/MRA.2015.2448277. | |
dc.source | R. Pfeifer, M. Lungarella y F. Iida, «The Challenges Ahead for Bio-Inspired ’Soft’ Robotics», Communications of the ACM, vol. 55, págs. 76-87, nov. de 2012. doi: 10.1145/2366316.2366335. | |
dc.source | A. Albu-Schaffer, M. Fischer, G. Schreiber, F. Schoeppe y G. Hirzinger, «Soft robotics: what Cartesian stiffness can obtain with passively compliant, uncoupled joints?», sep. de 2004, 3295-3301 vol.4, isbn: 0-7803-8463-6. doi: 10.1109/IROS.2004.1389925. | |
dc.source | G. Robinson y J. B. C. Davies, «Continuum robots - a state of the art», en Proceedings 1999 IEEE International Conference on Robotics and Automation (Cat. No.99CH36288C), vol. 4, mayo de 1999, 2849-2854 vol.4. doi: 10.1109/ROBOT.1999. 774029. | |
dc.source | B. Mazzolai y M. Cianchetti, «Soft robotics: Technologies and systems pushing the boundaries of robot abilities», Sci. Robotics, vol. 1, 2016. | |
dc.source | S. Kesner, L. Jentoft, F. Hammond, R. Howe y M. Popovic, «Design considerations for an active soft orthotic system for shoulder rehabilitation», Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Conference, vol. 2011, págs. 8130-4, ago. de 2011. doi: 10.1109/IEMBS.2011.6092006. | |
dc.source | T. Poliero, C. Di Natali, M. Sposito, J. Ortiz, E. Graf, C. Pauli, E. Bottenberg, A. De Eyto y D. G. Caldwell, «Soft wearable device for lower limb assistance: Assessment of an optimized energy efficient actuation prototype», en 2018 IEEE International Conference on Soft Robotics (RoboSoft), abr. de 2018, págs. 559-564. doi: 10.1109/ ROBOSOFT.2018.8405385. | |
dc.source | D. Caldwell, N. Tsagarakis, S. Kousidou, N. Costa e I. Sarakoglou, «"Soft.Exoskeletons for Upper and Lower Body Rehabilitation - Design, Control and Testing.», I. J. Humanoid Robotics, vol. 4, págs. 549-573, sep. de 2007. doi: 10.1142/S0219843607001151. | |
dc.source | J. Ortiz, E. Rocon, V. Power, A. de Eyto, L. O’Sullivan, M. Wirz, C. Bauer, S. Schuelein, K. S. Stadler, B. Mazzolai, W. B. Teeuw, C. T. M. Baten, C. D. M. Nikamp, J. H. Buurke, F. Thorsteinsson y J. Mueller, «XoSoft : a vision for a soft modular lower limb exoskeleton», 2017. | |
dc.source | J. Kwon, J. Park, S. Ku, Y. Jeong, N. Paik e Y. Park, «A Soft Wearable Robotic Ankle- Foot-Orthosis for Post-Stroke Patients», IEEE Robotics and Automation Letters, vol. 4, n.o 3, págs. 2547-2552, jul. de 2019. doi: 10.1109/LRA.2019.2908491. | |
dc.source | M. Sposito, S. Toxiri, D. Caldwell, J. Ortiz y E. De Momi, «Towards Design Guidelines for Physical Interfaces on Industrial Exoskeletons: Overview on Evaluation Metrics», oct. de 2018. | |
dc.source | M. Yandell, B. Quinlivan, D. Popov, C. Walsh y K. Zelik, «Physical interface dynamics alter how robotic exosuits augment human movement: implications for optimizing wearable assistive devices», Journal of NeuroEngineering and Rehabilitation, vol. 14, mayo de 2017. doi: 10.1186/s12984-017-0247-9. | |
dc.source | J. Gul, M. Sajid, M. Rehman, G. Siddiqui, I. Shah, K.-H. Kim, J.-W. Lee y K. Choi, «3D printing for soft robotics – a review», Science and Technology of Advanced Materials, vol. 19, págs. 243-262, dic. de 2018. doi: 10.1080/14686996.2018.1431862. | |
dc.source | A. C. Council, Introduction to Polyurethanes: Flexible Polyurethane Foam, urlpolyurethane- .americanchemistry.com/Flexible-Polyurethane-Foam/, 2015. | |
dc.source | S. Kurumaya, H. Nabae, G. Endo y K. Suzumori, «Exoskeleton inflatable robotic arm with thin McKibben muscle», en 2018 IEEE International Conference on Soft Robotics (RoboSoft), abr. de 2018, págs. 120-125. doi: 10.1109/ROBOSOFT.2018.8404907. | |
dc.source | N. Alavi, S. Zampierin, M. Komeili, S. Cocuzza, S. Debei y C. Menon, «A preliminary investigation into the design of pressure cushions and their potential applications for forearm robotic orthoses», BioMedical Engineering OnLine, vol. 16, mayo de 2017. doi: 10.1186/s12938-017-0345-8. | |
dc.source | W. Dijk, C. Meijneke y H. Kooij, «Evaluation of the Achilles Ankle Exoskeleton», IEEE Transactions on Neural Systems and Rehabilitation Engineering, vol. 25, págs. 1-1, ene. de 2016. doi: 10.1109/TNSRE.2016.2527780. | |
dc.source | L. Levesque, S. Pardoel, Z. Lovrenovic y M. Doumit, «Experimental comfort assessment of an active exoskeleton interface», oct. de 2017. doi: 10.1109/IRIS.2017.8250095. | |
dc.source | L. L. Sparks y J. M. Arvidson, «Thermal and mechanical properties of polyurethane foams and a survey of insulating concretes at cryogenic temperatures», abr. de 1984, pág. 64. doi: 10.1109/IRIS.2017.8250095. | |
dc.source | R. A. Española, ergonomía, urlhttps://dle.rae.es/srv/search?m=30w=ergonomía, 2019. (visitado 01-01-2019). | |
dc.source | A. Chiri, M. Cempini, S. M. M. De Rossi, T. Lenzi, F. Giovacchini, N. Vitiello y M. C. Carrozza, «On the design of ergonomic wearable robotic devices for motion assistance and rehabilitation», en 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, ago. de 2012, págs. 6124-6127. doi: 10.1109/EMBC. 2012.6347391. | |
dc.source | A. Schiele y F. C. T. van der Helm, «Kinematic Design to Improve Ergonomics in Human Machine Interaction», IEEE Transactions on Neural Systems and Rehabilitation Engineering, vol. 14, n.o 4, págs. 456-469, dic. de 2006. doi: 10.1109/TNSRE.2006. 881565. | |
dc.source | A. Stienen, E. Hekman, F. van der Helm y H. Kooij, «Self-Aligning Exoskeleton Axes Through Decoupling of Joint Rotations and Translations», Robotics, IEEE Transactions on, vol. 25, págs. 628-633, jul. de 2009. doi: 10.1109/TRO.2009.2019147. | |
dc.source | A. Schiele, «Fundamentals of ergonomic exoskeleton robots», Tesis doct., mayo de 2008. | |
dc.source | H. Herr, «Exoskeletons and orthoses: Classification, design challenges and future directions », Journal of neuroengineering and rehabilitation, vol. 6, pág. 21, jul. de 2009. doi: 10.1186/1743-0003-6-21. | |
dc.source | U. Ergonomics, TEST METHODS, urlhttps://us-ergo.com/ergonomics-laboratory/measurementtechnologies/, 2019. (visitado 01-01-2019). | |
dc.source | M. Gazzoni, B. Afsharipour y R. Merletti, «Surface EMG in Ergonomics and Occupational Medicine», en. abr. de 2016, págs. 361-391, isbn: 9781118987025. doi: 10.1002/9781119082934.ch13. | |
dc.source | W. Marras, «Overview of Electromyography in Ergonomics», Proceedings of the Human Factors and Ergonomics Society Annual Meeting, vol. 44, págs. 5-534, jul. de 2000. doi: 10.1177/154193120004403037. | |
dc.source | J. Chen, Y. Lei, J. Ding y Z. Wang, «The application of surface electromyography in the assessment of ergonomic risk factors associated with manual lifting tasks», Journal of Huazhong University of Science and Technology. Medical sciences = Hua zhong ke ji da xue xue bao. Yi xue Ying De wen ban = Huazhong keji daxue xuebao. Yixue Yingdewen ban, vol. 24, págs. 552-5, dic. de 2004. doi: 10.1007/BF02911352. | |
dc.source | B. Bioengineering, G-Walk inertial motion system, www.btsbioengineering.com/products/gwalk- inertial-motion-system/, 2019. (visitado 01-01-2015). | |
dc.source | T.-W. Lu y C.-F. Chang, «Biomechanics of human movement and its clinical applications », The Kaohsiung journal of medical sciences, vol. 28, S13-25, feb. de 2012. doi: 10.1016/j.kjms.2011.08.004. | |
dc.source | A. G. Thakurta, R. Iqbal y A. De, «The influence of three different load carrying methods on gait parameters of Indian construction workers», 2017. | |
dc.source | J. Knight y C. Baber, «A Tool to Assess the Comfort of Wearable Computers», Human factors, vol. 47, págs. 77-91, feb. de 2005. doi: 10.1518/0018720053653875. | |
dc.source | MSD. (2019). Valores normales para la amplitud de movimiento de las articulaciones Kernel Description, (visitado 10-10-2019). | |
dc.source | N. Kang y J. H. Cauraugh, «Force control in chronic stroke», Neuroscience Biobehavioral Reviews, vol. 52, págs. 38-48, 2015. | |
dc.source | H. Stolze, J. Kuhtz-Buschbeck, C. Mondwurf, A. Boczek-Funcke, K. Jöhnk, G. Deuschl y M. Illert, «Gait analysis during treadmill and overground locomotion in children and adults», Electroencephalography and clinical neurophysiology, vol. 105, págs. 490-7, ene. de 1998. doi: 10.1016/S0924-980X(97)00055-6. | |
dc.source | H. B. Menz, S. R. Lord y R. C. Fitzpatrick, «Acceleration patterns of the head and pelvis when walking on level and irregular surfaces», Gait & posture, vol. 18, n.o 1, págs. 35-46, 2003. | |
dc.source | A. A. of Physical Medicine y Rehabilitation. (2007). About Physical Medicine Rehabilitation, (visitado 04-09-2019). | |
dc.source | C. Yang, Y. Zhang J.F.and Chen, Y. Dong e Y. Zhang, «A Review of exoskeleton-type systems and their key technologies», Journal of Mechanical Engineering Science,, vol. 8, n.o 222, págs. 1599-1612, 2008. doi: 10.1243/09544062JMES936. | |
dc.source | J. Vantilt, K. Tanghe, M. Afschrift, A. Bruijnes, K. Junius, J. Geeroms, E. Aertbeliën, F. De Groote, D. Lefeber, I. Jonkers y J. De Schutter, «Model-based control for exoskeletons with series elastic actuators evaluated on sit-to-stand movements.», Journal of NeuroEngineering and Rehabilitation., vol. 16, n.o 65, 2003. doi: 16.10.1186/s12984- 019-0526-8. | |
dc.source | L. Luenberger, G. Colombo, R. Riener y V. Dietz, «Biofeedback in gait training with the robotic orthosis Lokomat.», IEEE Engineering in Medicine and Biology Society. Conference, vol. 7, n.o 10, págs. 4888-91, 2004. doi: 10.1109/IEMBS.2004.1404352.. | |
dc.source | D. P. Ferris, G. S. Sawicki y M. A. Daley., «A Physiologist’s perspective on robotic exoskeletons for human locomotion», The International Journal of Human Resource Management., vol. 4, n.o 3, págs. 507-528, sep. de 2007. doi: 10.1142/S0219843607001138. | |
dc.source | L. Levesque, S. Pardoel, Z. Lovrenovic y M. Doumit, «Experimental comfort assessment of an active exoskeleton interface», 2017 IEEE International Symposium on Robotics and Intelligent Sensors (IRIS), n.o 5, págs. 38-43, 2017. doi: 10.1109/IRIS.2017. 8250095. | |
dc.source | instname:Universidad del Rosario | |
dc.source | instname:Universidad del Rosario | |
dc.source | reponame:Repositorio Institucional EdocUR | |
dc.subject | Órtesis | |
dc.subject | Exoesqueleto | |
dc.subject | Rehabilitación física | |
dc.subject | Miembros inferiores | |
dc.title | Diseño y evaluación ergonómica de interfaces físicas para la órtesis robótica de tobillo (T-FLEX) a través de la integración de superficies blandas | |
dc.type | bachelorThesis | |