dc.contributor | Patiño Reyes, Nancy | |
dc.contributor | Varlet, Vincent | |
dc.contributor | Toxicología Ambiental y Ocupacional Toxicao | |
dc.contributor | Toxicologia Analitica | |
dc.creator | Villa Correa, Erica Sofia | |
dc.date.accessioned | 2022-01-31T21:52:53Z | |
dc.date.available | 2022-01-31T21:52:53Z | |
dc.date.created | 2022-01-31T21:52:53Z | |
dc.date.issued | 2021 | |
dc.identifier | https://repositorio.unal.edu.co/handle/unal/80822 | |
dc.identifier | Universidad Nacional de Colombia | |
dc.identifier | Repositorio Institucional Universidad Nacional de Colombia | |
dc.identifier | https://repositorio.unal.edu.co/ | |
dc.description.abstract | El monóxido de carbono es un gas que causa la muerte de cientos de personas en el mundo cada año. Para el diagnóstico y seguimiento de las intoxicaciones por la exposición a este agente, se usan métodos espectrofotométricos que cuantifican el porcentaje de saturación de carboxihemoglobina, identificándose limitaciones por interferentes tales como coágulos, lípidos y otros derivados de la hemoglobina. Durante los últimos veinte años, se han desarrollado metodologías analíticas cromatográficas para la determinación de la concentración de monóxido de carbono en muestras de sangre de casos forenses, observándose que estos resultados son más exactos y confiables que los obtenidos por la espectrofotometría ultravioleta-visible. Recientemente, se han adelantado investigaciones con el fin de establecer la concentración de monóxido de carbono total en sangre como nuevo biomarcador y con el objeto de contribuir a la comunidad científica en su construcción, se buscó durante el presente estudio, evaluar su relación con el porcentaje de saturación de carboxihemoglobina; para ello y con base en publicaciones, se desarrolló y validó un método cromatográfico, el cual se empleó en el análisis de cincuenta y dos muestras de sangre extraídas a treinta y nueve usuarios de ciclo rutas de Bogotá. A su vez, estás muestras también fueron analizadas por espectrofotometría visible. Los parámetros de desempeño del método para la “Determinación de la concentración de monóxido de carbono total” cumplen con los criterios de aceptación para la validación de metodologías bioanalíticas y al analizar los datos en la población objeto de estudio, no se encontró una relación lineal simple entre el porcentaje de saturación de carboxihemoglobina y la concentración de monóxido total. (Texto tomado de la fuente). | |
dc.description.abstract | Carbon monoxide is a gas that causes the death of hundreds of people in the world every year. For the diagnosis and monitoring of poisonings from exposure to this agent, spectrophotometric methods are used that quantify the percentage of carboxyhemoglobin saturation, identifying limitations by interferents such as clots, lipids and other derivatives of hemoglobin. During the last twenty years, chromatographic analytical methodologies have been developed for the determination of the concentration of carbon monoxide in blood in forensic cases, observing that these results are more accurate and reliable than those obtained by ultraviolet-visible spectrophotometry. Recently, research has been carried out in order to establish the concentration of total carbon monoxide in blood as a new biomarker and in order to contribute to the scientific community in its construction, it was sought during the present study to evaluate its relationship with the percentage of carboxyhemoglobin saturation; For this purpose and based on publications, a chromatographic method was developed and validated, which was used in the analysis of fifty-two blood samples taken from thirty-nine cycle users of Bogotá routes. In turn, these samples were also analyzed by visible spectrophotometry. The performance parameters of the method for the “Determination of the concentration of total carbon monoxide” meet the acceptance criteria for the validation of bioanalytical methodologies and when analyzing the data in the population under study, no simple linear relationship was found between the carboxyhemoglobin saturation percentage and the total monoxide concentration. | |
dc.language | spa | |
dc.publisher | Universidad Nacional de Colombia | |
dc.publisher | Bogotá - Medicina - Maestría en Toxicología | |
dc.publisher | Departamento de Toxicología | |
dc.publisher | Facultad de Medicina | |
dc.publisher | Bogotá, Colombia | |
dc.publisher | Universidad Nacional de Colombia - Sede Bogotá | |
dc.relation | Téllez J, Rodríguez A, Fajardo A. Contaminación por Monóxido de Carbono: un Problema de Salud Ambiental Ensayo/Essay. Rev salud pública [Internet]. 2006;8(1):108–17. Available from: http://www.scielosp.org/pdf/rsap/v8n1/v8n1a10.pdf | |
dc.relation | Anupam P, SK A, Nirupam P. Carbon Monoxide Poisoning. Apollo Med [Internet]. 2010;7(1):34–30. Available from: https://www.sciencedirect.com/science/article/abs/pii/S0976001612600040 | |
dc.relation | Roderique JD, Josef CS, Feldman MJ, Spiess BD. A modern literature review of carbon monoxide poisoning theories, therapies, and potential targets for therapy advancement. Toxicology [Internet]. 2015;334:45–58. Available from: http://dx.doi.org/10.1016/j.tox.2015.05.004 | |
dc.relation | Jaimes de Pino M, Hernandez Esquivel L. Determinación de niveles sanguíneos de carboxihemoglobina como función de la exposición al monóxido de carbono en la ciudad de Bogotá. Rev Colomb Ciencias Químico-Farmacéuticas [Internet]. 1990;18:21 a 27. Available from: https://revistas.unal.edu.co/index.php/rccquifa/article/view/56563 | |
dc.relation | Hampson NB, Bodwin D. Toxic CO-ingestions in intentional carbon monoxide poisoning. J Emerg Med [Internet]. 2013;44(3):625–30. Available from: http://dx.doi.org/10.1016/j.jemermed.2012.08.033 | |
dc.relation | Mattiuzzi C, Lippi G. Worldwide epidemiology of carbon monoxide poisoning. Hum Exp Toxicol [Internet]. 2020;39(4):387–92. Available from: https://journals.sagepub.com/doi/full/10.1177/0960327119891214?url_ver=Z39.88-2003&rfr_id=ori%3Arid%3Acrossref.org&rfr_dat=cr_pub++0pubmed | |
dc.relation | Instituto Nacional de Salud. Colombia. Instituto Nacional de Salud. Estadísticas de Vigilancia Rutinaria. 2021. p. 1. | |
dc.relation | McAllister J, Kunsman G, Levine B. Carbon Monoxyde/Cyanide. In: Levine B, Kerrigan S, editors. Principles of Forensic Toxicology. Fifth Edit. Frederick, MD, USA: company Springer Nature Switzerland AG; 2020. p. 678. | |
dc.relation | Tomaszeuski C. The clinical Basis of Medical Toxicology: Occupational and Environmental Toxins: Carbon Monoxide. In: Nelson L, Lewin N, Howland MA, Hoffman R, Goldfrank L, Flomenbaum N, editors. Goldfrank´s Toxicologic Emergencies. Ninth Edit. McGraw-Hill Companies.; 2011. p. 1969. | |
dc.relation | Oliverio S, Varlet V. Total Blood Carbon Monoxide: Alternative to Carboxyhemoglobin as Biological Marker for Carbon Monoxide Poisoning Determination. J Anal Toxicol [Internet]. 2019;43(2):79–87. Available from: https://academic.oup.com/jat/article/43/2/79/5146172 | |
dc.relation | Oliverio S, Varlet V. What are the limitations of methods to measure carbon monoxide in biological samples? Forensic Toxicol [Internet]. 2020;38(1). Available from: https://doi.org/10.1007/s11419-019-00490-1 | |
dc.relation | Oliverio S, Varlet V. Carbon monoxide analysis method in human blood by Airtight Gas Syringe – Gas Chromatography – Mass Spectrometry (AGS-GC-MS): Relevance for postmortem poisoning diagnosis. J Chromatogr B Anal Technol Biomed Life Sci [Internet]. 2018;1090(November 2017):81–9. Available from: https://doi.org/10.1016/j.jchromb.2018.05.019 | |
dc.relation | Oliverio S, Varlet V. New strategy for carbon monoxide poisoning diagnosis: Carboxyhemoglobin (COHb) vs Total Blood Carbon Monoxide (TBCO). Forensic Sci Int [Internet]. 2020;306(November):110063. Available from: https://doi.org/10.1016/j.forsciint.2019.110063 | |
dc.relation | Walch SG, Lachenmeier DW, Sohnius E-M, Madea B, Musshoff F. Rapid Determination of Carboxyhemoglobin in Postmortem Blood using Fully-Automated Headspace Gas Chromatography with Methaniser and FID. Open Toxicol J [Internet]. 2010;4:21–5. Available from: http://www.benthamscience.com/open/totoxij/articles/V004/21TOTOXIJ.pdf%5Cnpapers2://publication/uuid/253916DF-8FB2-4895-820E-5F4AABCABBDA | |
dc.relation | Hao H, Zhou H, Liu X, Zhang Z, Yu Z. An accurate method for microanalysis of carbon monoxide in putrid postmortem blood by head-space gas chromatography-mass spectrometry (HS/GC/MS). Forensic Sci Int [Internet]. 2013;229(1–3):116–21. Available from: https://pubmed.ncbi.nlm.nih.gov/23683916/ | |
dc.relation | Fajardo A, Rodríguez A, Téllez J, Prieto E, Mora G. Estudio comparativo del comportamiento clínico cardiovascular y electrocardiográfico en dos poblaciones expuestas a monóxido de carbono. Rev Fac Med Univ Nac Colomb [Internet]. 2012;60(4):303–10. Available from: https://revistas.unal.edu.co/index.php/revfacmed/article/view/38438/47248 | |
dc.relation | Czogała J, Wardas W, Goniewicz MŁ. Determination of low carboxyhemoglobin blood levels by gas chromatography. Anal Chim Acta [Internet]. 2006;556(2):295–300. Available from: https://www.sciencedirect.com/science/article/abs/pii/S0003267005016259 | |
dc.relation | Delivoria-Papadopoulos M, Coburn RF, Forster RE. Cyclic variation of rate of carbon monoxide production in normal women. J Appl Physiol [Internet]. 1974;36(l):49–51. Available from: www.physiology.org/journal/jappl at Midwestern Univ Lib (132.174.254.157) | |
dc.relation | Kaya H, Coşkun A, Beton O, Zorlu A, Kurt R, Yucel H, et al. Carboxyhemoglobin levels predict the long-term development of acute myocardial infarction in carbon monoxide poisoning. Am J Emerg Med [Internet]. 2016;34:840–4. Available from: http://www.ncbi.nlm.nih.gov/pubmed/26947364 | |
dc.relation | Coburn RF, Williams WJ, Kahn SB. Endogenous carbon monoxide production in patients with hemolytic anemia. J Clin Invest [Internet]. 1966;45(4):460–8. Available from: https://www.ncbi.nlm.nih.gov/pmc/articles/PMC292720/ | |
dc.relation | Contostavlos DL, Lichtenwalner M. A simple field test to detect elevated concentrations of carboxyhemoglobin in autopsy blood. J Clin Forensic Med [Internet]. 2003;10:77–80. Available from: https://pubmed.ncbi.nlm.nih.gov/15275025/ | |
dc.relation | Sáez PO, Soto AB, Ortega AG, García RD, Ramírez PG, Campuzano EG, et al. Recomendaciones para el estudio de la cooximetría [Internet]. 2010. Report No.: Documento M. Fase 3. Versión 2. Available from: http://www.seqc.es/download/doc/67/2840/951224035/603430/cms/recomendaciones-para-el-estudio-de-la-cooximetria-2010.pdf/ | |
dc.relation | Berg J. Biochemistry. In: Biochemistry [Internet]. Eight Edit. W. H. Freeman; 2015. p. 183–94. Available from: https://www.academia.edu/18009796/7_Hemoglobin | |
dc.relation | Sagala DD. Paper Hemoglobin dan Eritropoesis [Internet]. 2015. Available from: https://www.academia.edu/30099142/Paper_hemoglobin | |
dc.relation | Skoog DA, Holler JF, Crouch SR. Principios de análsis instrumental. Vol. 53, CENGAGE Learning. 2008. 1689–1699 p. | |
dc.relation | Levine, Barry; Cody JSPV. Principles of Forensic Toxicology. Fourth. Principles of Forensic Toxicology. Washington D.C: AACC Press; 2013. 550 p. | |
dc.relation | Boumba VA, Vougiouklakis T. Evaluation of the methods used for carboxyhemoglobin analysis in postmortem blood. Int J Toxicol [Internet]. 2005;24:275–81. Available from: http://www.ncbi.nlm.nih.gov/pubmed/16126621 | |
dc.relation | arlet V, Lagroy De Croutte E, Augsburger M, Mangin P. Accuracy profile validation of a new method for carbon monoxide measurementin the human blood using headspace-gas chromatography–mass spectrometry(HS-GC–MS). J Chromatogr B Anal Technol Biomed Life Sci [Internet]. 2012;880(1):125–31. Available from: http://dx.doi.org/10.1016/j.jchromb.2011.11.028 | |
dc.relation | Heredia P. Validación de la metodología para la determinación de carboxihemoglobina por espectrofotometría visible en muestras de sangre, código DRBO-M-IVT-LTOF-177-V01. Instituto Nacional de Medicina Legal y Ciencias Forenses. Bogotá; 2015. | |
dc.relation | Corporation R. A Technical Guide for Static Headspace Analysis Using GC. In: Corporation R, editor. A Technical Guide for Static Headspace Analysis Using GC [Internet]. Restek Corporation; p. 20. Available from: https://www.restek.com/pdfs/59895B.pdf | |
dc.relation | Varlet V, De Croutte EL, Augsburger M, Mangin P. A new approach for the carbon monoxide (CO) exposure diagnosis: Measurement of total co in human blood versus carboxyhemoglobin (HbCO). J Forensic Sci [Internet]. 2013;58(4):1041–6. Available from: https://pubmed.ncbi.nlm.nih.gov/23692308/ | |
dc.relation | Mureşan CO, Taloş I, Sturz V, Enache A. Carboxyhemoglobin stability evaluation in stored and heat-treated biological samples. Rom J Leg Med [Internet]. 2013;21(3):239–44. Available from: https://pdfs.semanticscholar.org/fac0/b20861bd5246e0b4afb0933c0225619a268c.pdf | |
dc.relation | Nagai K. Estimation of carboxyhemoglobin concentrations in thermo-coagulated blood on a CO-oximeter system: an experimental study. Forensic Sci Int [Internet]. 1996;83(3):211–8. Available from: https://www.sciencedirect.com/science/article/pii/S0379073896020397 | |
dc.relation | Kunsman GW, Presses CL, Rodriguez P. Carbon monoxide stability in stored postmortem blood samples. J Anal Toxicol [Internet]. 2000;24(7):572–8. Available from: http://www.ncbi.nlm.nih.gov/pubmed/11043662 | |
dc.relation | Chace DH, Goldbaum LR, Lappas NT. Factors affecting the loss of carbon monoxide from stored blood samples. J Anal Toxicol [Internet]. 1986;10(5):181–9. Available from: https://pubmed.ncbi.nlm.nih.gov/3773478/ | |
dc.relation | Vocabulario Internacional de Metrología, Conceptos fundamentales y generales, y términos asociados,. In: Centro Español de Metrología [Internet]. JCGM; 2012. p. 88. Available from: https://www.cem.es/sites/default/files/vim-cem-2012web.pdf | |
dc.relation | Pulido J. Tesis de Maestría: determinación simultanea de THCA y Benzoilecgonina en orina por cromatografía de gases con espectrometría de masas como biomarcadores de exposición a cannabis y cocaína. [Internet]. Universidad Nacional de Colombia; 2016. Available from: https://repositorio.unal.edu.co/handle/unal/57595 | |
dc.relation | Agency EM. ICH topic Q2 (R1). Validation of Analytical Procedures: Text and Methodology. In: Prescrire International [Internet]. London: European Medicines Agency; 2006. p. 278. Available from: https://www.ema.europa.eu/en/documents/scientific-guideline/ich-q-2-r1-validation-analytical-procedures-text-methodology-step-5_en.pdf | |
dc.relation | Heredia P. Monografía: Guía para la validación de métodos bioanalíticos: Aplicación a la Toxicología Forense. Universidad Nacional de Colombia sede Bogotá; 2001. | |
dc.relation | Pértegas Díaz, S.; Pita Fernández S. Determinación del tamaño muestral para calcular la significación del coeficiente de correlación lineal. Cad Aten Primaria [Internet]. 2002;9:209–11. Available from: https://www.fisterra.com/gestor/upload/guias/pearson2.pdf | |
dc.relation | Londo C. Questionnaire to Classify the Level of Tobacco Consumption in Young People. Perspect Psicol [Internet]. 2011;7(2):281–91. Available from: http://www.scielo.org.co/scielo.php?script=sci_arttext&pid=S1794-99982011000200007&lng=en&nrm=iso | |
dc.relation | Team RDC. R: A Language and Environment for Statistical Computing. [Internet]. Vienna, Austria: R Foundation for Statistical Computing; 2008. Available from: https://www.r-project.org | |
dc.relation | Alfisz, Stephan; Fajardo, Diana; Villa, Erica; Patiño N. Trabajo de grado: Evaluación de la estabilidad de carboxihemoglobina en muestras de sangre total almacenadas en diferentes condiciones a partir de la revalidación de una metodología analítica por espectrofotometría uv-visible. Universidad Nacional de Colombia, sede Bogotá.; 2019. | |
dc.relation | Miller JN, Miller J. Métodos de calibración en análisis instrumental: regresión y correlación. In: Capella I, Caicoya M, editors. Estadística y quimiometría para química analítica. Cuarta Edi. Madrid: Pearson Educación S.A; 2002. p. 111–50. | |
dc.relation | Mongay Fernández C. Análisis de la varianza. In: Capilla, Juli. Hernández de la Figuera, Celso. Fuster, Pere. Navaab Akbar S, editor. Quimiometría. 1st ed. Valencia, España: Universidad de Valencia; 2005. p. 129–53. | |
dc.relation | Mongay Fernández C. Regresión lineal simple. In: Capilla J, Hernández de la Figuera C, Fuster P, Navaab Akbar S, editors. Quimiometría. Valencia, España: Universidad de Valencia; 2005. p. 281–300. | |
dc.relation | Ministerio de Salud C. Por la cual se establecen las normas científicas, técnicas y administrativas para la investigación en salud. [Internet]. Colombia: Ministerio de Salud; 1993 p. 19. Available from: https://www.minsalud.gov.co/sites/rid/Lists/BibliotecaDigital/RIDE/DE/DIJ/RESOLUCION-8430-DE-1993.PDF | |
dc.relation | Mongay Fernández C. Principios de quimiometría. In: Capilla, Juli. Hernández de la Figuera, Celso. Fuster, Pere. Navaab Akbar S, editor. Quimiometría. Valencia, España: Universidad de Valencia; 2005. p. 19–32. | |
dc.relation | Marcano L, Fermín W. Comparación de métodos de detección de datos anómalos multivariantes mediante un estudio de simulación. Saber, Univ Oriente, Venez [Internet]. 2013;25:192–201. Available from: http://ve.scielo.org/pdf/saber/v25n2/art09.pdf | |
dc.relation | Lindell K W. Cinical Prectice: Carbon monoxide poisoning. N Engl J Med. 2009;360(12):1217–25. | |
dc.rights | Atribución-NoComercial 4.0 Internacional | |
dc.rights | http://creativecommons.org/licenses/by-nc/4.0/ | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.title | Relación entre concentración de monóxido de carbono total en sangre y porcentaje de saturación de carboxihemoglobina por cromatografía de gases-espectrometría de masas y espectrofotometría UV/Vis | |
dc.type | Trabajo de grado - Maestría | |