Funcionamiento y aplicación de la técnica de miografía de alambre como método para evaluar la función endotelial y reactividad vascular
dc.contributor | Martínez Sánchez, Miguel Eduardo | |
dc.creator | Zorrilla Urbina, Javier Stiwer | |
dc.date.accessioned | 2020-03-05T20:17:45Z | |
dc.date.available | 2020-03-05T20:17:45Z | |
dc.date.created | 2020-03-05T20:17:45Z | |
dc.date.issued | 2019-12-12 | |
dc.identifier | https://repositorio.unal.edu.co/handle/unal/75896 | |
dc.description.abstract | The wire myography technique is part of one of the classic vascular physiology techniques used to measure vasoreactivity. In previous years (before the 1970s), most of the information on the mechanical, morphological and pharmacological properties of vascular smooth muscle was limited only to large arteries (mainly aorta). While information on smaller arteries were derived from perfusion experiments and histological examination. However, in the mid-1970s, Dr. Mulvany and Halpern developed and introduced the technique of wire myography, to study the contractile responses of small arteries isolated from resistance (approximately 100-300 micrometers in the internal diameter). in vitro of the isometric tension developed by a segment of the vessel in response to different pathophysiological stimuli. This technique has been used in different studies of vasoreactivity both physiological, pathophysiological and pharmacological, such that it has become a key instrument for the compression and experimentation of models that allow clarifying the functioning of endothelial reactivity in different scenarios. Since one of the approaches is to understand the physiological mechanics of vasoreactivity, it is of great importance that during the time of training of professionals in health areas you can allow such experimentation allowing to elucidate the mechanisms involved in the process of vasorelaxation and vasoconstriction. | |
dc.description.abstract | La técnica de miografía de alambre hace parte de una de las técnicas clásicas de fisiología vascular que se utiliza para medir la vasoreactividad. En años anteriores (antes de la década de 1970), la mayor parte de la información sobre las propiedades mecánicas, morfológicas y farmacológicas del músculo liso vascular se limitaba solo a las arterias grandes (principalmente aorta). Mientras que la información sobre arterias más pequeñas se dedujeron de los experimentos de perfusión y el examen histológico. Sin embargo a mediados de la década de 1970 los Doctores Mulvany y Halpern desarrollaron e introdujeron la técnica de miografía de alambre, para estudiar las respuestas contráctiles de pequeñas arterias aisladas de resistencia (aproximadamente 100-300 micrómetros en el diámetro interno).permitiendo el monitoreo in vitro de la tensión isométrica desarrollada por un segmento del vaso en respuesta a diferentes estímulos fisiopatológicos. Dicha técnica ha sido utilizada en diferentes estudios de vasoreactividad tanto fisiológicos, fisiopatológicos y farmacológicos, que tal manera que se ha convertido en instrumento clave para la compresión y experimentación de modelos que permitan aclarar el funcionamiento de la reactividad endotelial en diferentes escenarios. Ya que uno de los enfoques es entender los mecánicos fisiológicos de la vasoreactividad, es de gran importancia que durante el tiempo de formación de los profesionales en áreas de la salud se puede permitir realizar dicha experimentación permitiendo dilucidar los mecanismos que intervienen en el proceso de vasorelajación y vasoconstricción. | |
dc.language | spa | |
dc.publisher | Universidad Nacional de Colombia - Sede Bogotá | |
dc.relation | Angus, J. A., & Wright, C. E. (2000). Techniques to study the pharmacodynamics of isolated large and small blood vessels. Journal of Pharmacological and Toxicological Methods, 44(2), 395–407. https://doi.org/10.1016/S1056-8719(00)00121-0 Brunton Laurence L., Lazo John S., Parker Keith L. “Goodman & Gilman. Las bases farmacológicas de la Terapéutica”. Undécima Edición. McGraw Hill. 2006 Cabrera, L., Saavedra, A., Rojas, S., Cid, M., Valenzuela, C., Gallegos, D., … González, M. (2016). Insulin induces relaxation and decreases hydrogen peroxide-induced vasoconstriction in human placental vascular bed in a mechanism mediated by calcium-activated potassium channels and L-arginine/nitric oxide pathways. Frontiers in Physiology, 7(NOV), 1–13. https://doi.org/10.3389/fphys.2016.00529 Campo, L., & Ferrer, M. (2015). Methods in Mouse Atherosclerosis. 1339. https://doi.org/10.1007/978-1-4939-2929-0 del Campo, L., Ferrer, M., Ping, N.-N. N. na, Cao, L., Xiao, X., Li, S., … Cao, Y.-X. Y. xia. (2015). Wire Myography to Study Vascular Tone and Vascular Structure of Isolated Mouse Arteries. Physiological Research, 1339(1), 156–158. https://doi.org/10.1016/j.mvr.2014.11.001 Fennell, J. P., Baker, A. H., Spiers, A., & Padmanabhan, N. (2005). A Guide to Wire Myography. Hypertension, 108(3), 091–104. https://doi.org/10.1385/1-59259-850-1:091 Ghantous, C. M., Azrak, Z., Rahman, F. A., Itani, H. A., & Zeidan, A. (2016). Assessment of basilar artery reactivity in stroke and subarachnoid hemorrhage using wire myograph. In Methods in Molecular Biology (Vol. 1462, pp. 625–643). https://doi.org/10.1007/978-1-4939-3816-2_34 HALPERN, W., MULVANY, M. J., & WARSHAW, D. M. (1977). Mechanical properties of smooth muscle cells. pp. 441-8. In:.Casteels.R,.et.Al., WE 500 I61, 85–101. McPherson, G. A. (1992). Assessing Vascular Reactivity of Arteries in the Small Vessel Myograph. Clinical and Experimental Pharmacology and Physiology, 19(12), 815–825. https://doi.org/10.1111/j.1440-1681.1992.tb00420.x Nielsen-Kudsk, F., Poulsen, B., Ryom, C., & Nielsen-Kudsk, J. E. (1986). A strain-gauge myograph for isometric measurements of tension in isolated small blood vessels and other muscle preparations. Journal of Pharmacological Methods, 16(3), 215–225. https://doi.org/10.1016/0160-5402(86)90043-4 Puzserova, A., Physiology, P., & Slezak, P. (2011). Stanovenie cievnej reaktivity pomocou drôtikového myografu Assessment of vascular reactivity by wire myograph. (January 2014). Sun, J., Yang, G. M., Tao, T., Wei, L. S., Pan, Y., & Zhu, M. S. (2018). Isometric Contractility Measurement of the Mouse Mesenteric Artery Using Wire Myography. Journal of Visualized Experiments, (138), 1–6. https://doi.org/10.3791/58064 Xiao, X., Ping, N. na, Li, S., Cao, L., & Cao, Y. xia. (2015). An optimal initial tension for rat basilar artery in wire myography. Microvascular Research, 97, 156–158. https://doi.org/10.1016/j.mvr.2014.11.001 | |
dc.rights | Atribución-NoComercial 4.0 Internacional | |
dc.rights | Acceso abierto | |
dc.rights | http://creativecommons.org/licenses/by-nc/4.0/ | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights | Derechos reservados - Universidad Nacional de Colombia | |
dc.title | Funcionamiento y aplicación de la técnica de miografía de alambre como método para evaluar la función endotelial y reactividad vascular | |
dc.type | Otro |