dc.contributor | Villalba Morales, Jesús Daniel | |
dc.contributor | Molina Herrera, Maritzabel | |
dc.creator | Gómez Navarrete, Diana Catalina | |
dc.date.accessioned | 2020-12-10T18:27:22Z | |
dc.date.available | 2020-12-10T18:27:22Z | |
dc.date.created | 2020-12-10T18:27:22Z | |
dc.date.issued | 2020-12-10 | |
dc.identifier | https://repositorio.unal.edu.co/handle/unal/78696 | |
dc.description.abstract | Viscous fluid dampers are a seismic protection alternative that improve the dynamic performance of buildings under seismic events. These devices concentrate their actions mechanism (movement of the fluid inside) to dissipate seismic energy which get into the building and to reduce the level of damage to the main structure. The viscous fluid dampers improve the dynamic behavior of buildings by the increment of the viscous damping, which rise energy dissipation in the structures.
Taking into account that the Colombian Design Code (NSR-10) reports only R coefficient of conventional structures, whose values are not related directly to buildings with energy-dissipation systems, in this investigation the energy dissipation coefficient R of 5 reinforced concrete frame devices is found out in different structures heights: 4, 8, 12, 16 and 20 floors. The analysis and design of the buildings was carried out in accordance with the NSR-10 regulations and the parameters for structures with energy dissipation systems included in the ASCE 7-16 document. The R coefficient is determined from the inelastic behavior of buildings with energy-dissipation devices obtained by using a proposed method of non-linear response history analysis. This procedure was validated using pushover analysis as a reference, but the difference, is that the proposed method considers the velocity-dependent response of the damping devices.
This work contributes in research related to seismic protection systems in order to promote their use in Colombia. | |
dc.description.abstract | Los disipadores de energía de fluido viscosos son una alternativa de protección sísmica que busca mejorar el desempeño dinámico de la edificación frente a un evento sísmico. Estos dispositivos tienen como propósito concentrar en su mecanismo de acción (movimiento del fluido en su interior) la disipación de la energía que ingresa al sistema y reducir el daño de los elementos de la estructura principal. El aporte que proporcionan estos dispositivos en el comportamiento dinámico de una edificación se basa en el aumento del amortiguamiento viscoso, con el cual se genera un mecanismo adicional de disipación de energía en la estructura.
Teniendo en cuenta que el reglamento NSR-10 solo contempla coeficientes R de estructuras convencionales, cuyos valores no se pueden asociar directamente a la capacidad de disipación de energía de una edificación que incluye sistemas de protección sísmica, en la presente investigación se determina el coeficiente de disipación de energía R en 5 edificaciones de pórticos en concreto reforzado con disipadores viscosos, las cuales presentan diferentes alturas: 4, 8, 12, 16 y 20 pisos. El análisis y diseño de las edificaciones se desarrolló de acuerdo con el reglamento NSR-10 y los parámetros establecidos para estructuras con sistemas de disipación descritos en el documento ASCE 7-16. El cálculo del coeficiente R se determina a partir del comportamiento inelástico de las edificaciones con disipadores viscosos, obtenido por medio de una metodología de análisis dinámico cronológico no lineal propuesta. Dicho procedimiento es validado tomando como referencia el método de análisis no lineal estático de plastificación progresiva pero que, a diferencia de este último, incluye la respuesta dinámica de los disipadores de energía viscosos.
Este trabajo busca contribuir en el desarrollo de las investigaciones relacionadas a sistemas de protección sísmica para promover su uso en Colombia. | |
dc.language | spa | |
dc.publisher | Bogotá - Ingeniería - Maestría en Ingeniería - Estructuras | |
dc.publisher | Universidad Nacional de Colombia - Sede Bogotá | |
dc.relation | Abdi, H., Hejazi, F., Jaafar, M. S., Binti, I., & Karim, A. (2018). Response Modification Factors for Reinforced Concrete Structures Equipped with Viscous Damper Devices. Periodica Polytechnica Civil Engineering, 62(1), 11–25 | |
dc.relation | Abdi, H., Hejazi, F., Saifulnaz, R., Karim, I. A., & Jaafar, M. S. (2015). Response modification factor for steel structure equipped with viscous damper device. International Journal of Steel Structures, 15(3). https://doi.org/10.1007/s13296-015-9008-4 | |
dc.relation | Aguiar, R. (2007). Factor de reducción de fuerzas sísmicas en edificios de hormigón armado sin muros de corte | |
dc.relation | Applied Technology Council. (1995a). ATC-19 Structural Response Modification Factors | |
dc.relation | Applied Technology Council. (1995b). ATC-40 Seismic Evaluation and Retrofit of Concrete Buildings. ATC 40 (Vol. 1). California. https://doi.org/10.1193/1.1586093 | |
dc.relation | Ardila Valencia, J. G. (2016). Evaluación del Coeficiente de Disipación de Energía, R, para Edificios con un Sistema Estructural Combinado de Muros y Pórticos en Concreto, con Diferente Número de Pisos. Universidad Nacional de Colombia | |
dc.relation | ASCE, A. S. of C. E. (2017). ASCE 7-16. Reston, Virginia | |
dc.relation | Asociación Colombiana de Ingeniería Sísmica, A. (2010). TITULO A - NSR-10. Reglamento Colombiano de Construcción Sismo Resistente (Vol. Titulo A) | |
dc.relation | Cancelado, R. A. (2012). Caracterización mecánica y modelamiento estructural de un disipador pasivo de energia de tipo arriostramiento de pandeo restringido. Parte 1. Universidad Nacional de Colombia | |
dc.relation | Castaldo, P. (2008). Integrated Seismic Design of Structure and Control Systems. Interface (Vol. 9). https://doi.org/10.1080/09298218008570294 | |
dc.relation | Chopra, A. K. (2014). Dinámica de Estructuras (Cuarta Edi). Pearson | |
dc.relation | Computers & Structures, I. (2016). Analysis Reference Manual CSI Anal y sis Reference Manual | |
dc.relation | Espejel Acosta, O. Á. (2013). Estudio analítico del comportamiento de una estructura reforzada con disipadores pasivos de energía | |
dc.relation | Federal Emergency Management Agency. (1997). FEMA 274 | |
dc.relation | Federal Emergency Management Agency. (2003). FEMA 450 - Commentary | |
dc.relation | García Reyes, L. E. (1998). Dinámica Estructural Aplicada al Diseño Sísmico. (U. de los Andes, Ed.). Bogotá: Universidad de Los Andes | |
dc.relation | Gómez, D., Marulanda, J., & Thomson, P. (2007). Sistemas de Control para la Protección de Estructuras Civiles Sometidas a Cargas Dinámicas. Dyna-Colombia, (155), 77–89 | |
dc.relation | Guevara Huatuco, D. N., & Arias Torres, P. O. (2012). Diseño de un Edificio Aporticado con Amortiguadores de Fluido-Viscoso en Disposición Diagonal, 89. Retrieved from http://tesis.pucp.edu.pe:8080/repositorio/handle/123456789/1477 | |
dc.relation | Higashino, M., & Okamoto, S. (2006). Response Control and Seismic Isolation of Buildings. CIB | |
dc.relation | Hwang, J., Lin, W., & Wu, N. (2010). Comparison of distribution methods for viscous damping coefficients to buildings. Structure and Infrastructure Engineering, 9(January 2013), 28–41. https://doi.org/10.1080/15732479.2010.513713 | |
dc.relation | Lande, P. S., & Wankhade, S. V. (2018). Evaluation and Comparison of Response Reduction Factor ( R factor ) for RCC Frame Provided with Viscous Damper by Response Spectrum Analysis. International Research Journal of Engineering and Technology, 05(05) | |
dc.relation | Landi, L., Conti, F., & Diotallevi, P. P. (2014). Influence of vertical distribution of damper properties for seismic upgrading of regular and irregular rc frames, 25–29 | |
dc.relation | Lin, T. K., Hwang, J. S., & Chen, K. H. (2017). Optimal Distribution of Damping Coefficients for Viscous Dampers in Buildings. International Journal of Structural Stability and Dynamics, 17(4), 1–19. https://doi.org/10.1142/S0219455417500547 | |
dc.relation | Mendez Romero, H. (2011). Efecto de las Deformaciones por Cortante en los Diagramas Momento-Curvatura de Secciones de Concreto Reforzado y sus Implicaciones en la Evaluación y Diseño Sísmico de Estructuras. Universidad Nacional Autonoma de México | |
dc.relation | Navarro Viera, F. (2017). Comparación de las respuestas dinámicas en estructuras con y sin disipadores de energía pasivos de fluido viscoso en la zona sísmica cuatro | |
dc.relation | Newmark, N. M., & Hall, W. J. (1982). Earthquake Spectra and Design - EERI Monographs. Earthquake Engineering Research Institute | |
dc.relation | Oviedo, J. A., & Duque, M. del P. (2009). Situación de las Técnicas de Control de Respuesta Sísmica en Colombia. Escuela de Ingeniería de Antioquia, EIA, 12(1794–1237), 113–124 | |
dc.relation | Parsaeimaram, M., Congqi, F., Luo, X., & Shakya, C. (2018). Seismic Performance Evaluation of Double Skin Semi-Base-Isolated Building Using Incremental Dynamic Analysis. Advances in Civil Engineering, 2018, 19 | |
dc.relation | Romero Urrunaga, D. O. (2013). Diseño de Edificaciones con Disispadores de Energía Sísmica de Tipo Fluido Viscoso | |
dc.relation | Symans, M. D., Charney, F. A., Whittaker, A. S., Constantinou, M. C., Kircher, C. A., Johnson, M. W., & Mcnamara, R. J. (2008). Energy Dissipation Systems for Seismic Applications: Current Practice and Recent Developments. Journal of Structural Engineering, 134(1), 3–21 | |
dc.relation | Taylor. (2018). Structural Applications of Taylor Fluid Viscous Dampers | |
dc.relation | Valencia Restrepo, D., & Valencia Clement, G. (2008). Evaluación del coeficiente de disipación de energía, R, para algunos tipos de estructuras de acero. Ingeniería e Investigación, 28(1), 41–49 | |
dc.relation | Vamvatsikos, D., & Allin Cornell, C. (2002). Incremental dynamic analysis. Earthquake Engineering and Structural Dynamics, 31(3), 491–514. https://doi.org/10.1002/eqe.141 | |
dc.relation | Villarreal, G., & Díaz La Rosa, M. (2016). Edificaciones con disipadores viscosos | |
dc.relation | Yao, J. T. P. (1972). Concept of Structural Control. Journal of the Structural Division, ASCE, 98(ST7), 1567–1574 | |
dc.rights | Atribución-NoComercial-SinDerivadas 4.0 Internacional | |
dc.rights | Acceso abierto | |
dc.rights | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights | Derechos reservados - Universidad Nacional de Colombia | |
dc.title | Evaluación del coeficiente de disipación de energía R en edificaciones de concreto reforzado con disipadores de energía viscosos ubicados en zona de amenaza sísmica alta | |
dc.type | Otro | |