The functional gain is used in the validation of the process adaptation of hearing aids.
This research presented as main aim to perform a study comparing the use of pure
tone with the warble tone of the functional gain in users of hearing aid. To participate
of the research the patients they would have to take care with some criterious:
present bilateral sensorineural hearing loss, timpanometry curve type A (Jerger), use
binaural hearing aids digital, with two canals, to be in process adaptation and present
cognitive ability to understand the test instructions. The sample studied was made
with 16 patients between 62 and 90 years old. These people signed the free
permission term, answered the interview and they were submitted to tests in free
field. After the selection of the patients was realized hearing evaluation with and
without hearing aid in free field, using the frequencies 500, 1000, 2000, 3000 and
4000 Hz. On the basis of the results, had been established the values of reference
for the functional gain of hearing aid, with the different used tones. The results found
through the analysis statistics using the test Mann-Whitney had shown that
statistically significant difference was found between the mean of gain with pure tone
and with tone warble for all the analyzed frequencies. After the realization this study it
was, concluded that, the use of the tone warble, in the functional gain, to present
accurater results when comparative to the use of the pure tone in the frequencies of
2000, 3000 and 4000 Hz