dc.contributorBier, Carlos Alexandre Souza
dc.contributorhttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4705683J8
dc.contributorMóra, Patrícia Maria Poli Kopper
dc.contributorhttp://lattes.cnpq.br/4183990675049766
dc.contributorSó, Marcus Vinicius Reis
dc.contributorhttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4773827A4
dc.creatorSantini, Manuela Favarin
dc.date.accessioned2012-09-18
dc.date.available2012-09-18
dc.date.created2012-09-18
dc.date.issued2012-03-03
dc.identifierSANTINI, Manuela Favarin. EFFECT OF THE INSTRUMENT TYPE AND ROOT CANAL FILLING TECHNIQUE ON FRACTURE RESISTANCE OF RESTORED ROOTS. 2012. 56 f. Dissertação (Mestrado em Odontologia) - Universidade Federal de Santa Maria, Santa Maria, 2012.
dc.identifierhttp://repositorio.ufsm.br/handle/1/6081
dc.description.abstractThe aim of this study was to assess the effect of instrument type (K-files and nickel-titanium rotary files) and the root canal filling technique (active and passive lateral condensation) on fracture resistance. Sixty eight teeth (canines and premolars) were divided into 4 groups (n=17): G1 - hand instrumentation and active lateral condensation; G2 - hand instrumentation and passive lateral condensation; G3 - rotary instrumentation and active lateral condensation; G4 - rotary instrumentation and passive lateral condensation. Before the filling, the roots were embedded in acrylic resin to simulate the periodontal ligament using a polyether impression material. Every root was restored with glass fiber post and metallic crown. The specimens were mechanical cycled (500.000 cycles, 45°, 37° C, 133 N, 2 Hz) and they were submitted to fracture test (45º, 1 mm/ min) until the fracture occurred. The Kruskal-Wallis test showed that the groups were not different from each other (p = 0. 247). In situations where an endodontic post is required, the instrument type and the obturation technique seem to have no influence on fracture resistance.
dc.publisherUniversidade Federal de Santa Maria
dc.publisherBR
dc.publisherOdontologia
dc.publisherUFSM
dc.publisherPrograma de Pós-Graduação em Ciências Odontológicas
dc.rightsAcesso Aberto
dc.subjectInstrumentos endodônticos
dc.subjectTécnicas obturadoras
dc.subjectFratura vertical de raiz
dc.subjectPino de fibra de vidro
dc.subjectEndodontic instruments
dc.subjectRoot canal filling techniques
dc.subjectVertical root fracture
dc.subjectGlass fiber post
dc.titleEfeito do tipo de instrumento e da técnica obturadora na resistência à fratura de dentes restaurados
dc.typeDissertação


Este ítem pertenece a la siguiente institución