dc.contributor | Bier, Carlos Alexandre Souza | |
dc.contributor | http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4705683J8 | |
dc.contributor | Móra, Patrícia Maria Poli Kopper | |
dc.contributor | http://lattes.cnpq.br/4183990675049766 | |
dc.contributor | Só, Marcus Vinicius Reis | |
dc.contributor | http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4773827A4 | |
dc.creator | Santini, Manuela Favarin | |
dc.date.accessioned | 2012-09-18 | |
dc.date.available | 2012-09-18 | |
dc.date.created | 2012-09-18 | |
dc.date.issued | 2012-03-03 | |
dc.identifier | SANTINI, Manuela Favarin. EFFECT OF THE INSTRUMENT TYPE AND ROOT CANAL FILLING TECHNIQUE ON FRACTURE RESISTANCE OF RESTORED ROOTS. 2012. 56 f. Dissertação (Mestrado em Odontologia) - Universidade Federal de Santa Maria, Santa Maria, 2012. | |
dc.identifier | http://repositorio.ufsm.br/handle/1/6081 | |
dc.description.abstract | The aim of this study was to assess the effect of instrument type (K-files and nickel-titanium rotary files) and the root canal filling technique (active and passive lateral condensation) on fracture resistance. Sixty eight teeth (canines and premolars) were divided into 4 groups (n=17): G1 - hand instrumentation and active lateral condensation; G2 - hand instrumentation and passive lateral condensation; G3 - rotary instrumentation and active lateral condensation; G4 - rotary instrumentation and passive lateral condensation. Before the filling, the roots were embedded in acrylic resin to simulate the periodontal ligament using a polyether impression material. Every root was restored with glass fiber post and metallic crown. The specimens were mechanical cycled (500.000 cycles, 45°, 37° C, 133 N, 2 Hz) and they were submitted to fracture test (45º, 1 mm/ min) until the fracture occurred. The Kruskal-Wallis test showed that the groups were not different from each other (p = 0. 247). In situations where an endodontic post is required, the instrument type and the obturation technique seem to have no influence on fracture resistance. | |
dc.publisher | Universidade Federal de Santa Maria | |
dc.publisher | BR | |
dc.publisher | Odontologia | |
dc.publisher | UFSM | |
dc.publisher | Programa de Pós-Graduação em Ciências Odontológicas | |
dc.rights | Acesso Aberto | |
dc.subject | Instrumentos endodônticos | |
dc.subject | Técnicas obturadoras | |
dc.subject | Fratura vertical de raiz | |
dc.subject | Pino de fibra de vidro | |
dc.subject | Endodontic instruments | |
dc.subject | Root canal filling techniques | |
dc.subject | Vertical root fracture | |
dc.subject | Glass fiber post | |
dc.title | Efeito do tipo de instrumento e da técnica obturadora na resistência à fratura de dentes restaurados | |
dc.type | Dissertação | |