Dissertação
Determinação do número de acidez total em resíduo de destilação atmosférica e de vácuo do petróleo empregando a espectroscopia no infravermelho (ATR-FTIR) e calibração multivariada
Fecha
2007-12-14Registro en:
PARISOTTO, Graciele. Determinação do número de acidez total em resíduo de destilação atmosférica e de vácuo do petróleo empregando a espectroscopia no infravermelho (ATR-FTIR) e calibração multivariada. 2007. 102 f. Dissertação (Mestrado em Química) - Universidade Federal de Santa Maria, Santa Maria, 2007.
Autor
Parisotto, Graciele
Institución
Resumen
The crude oil might contain a series of contaminants that can to produce undesired properties. Naphthenic acids (NA), for example, perhaps promotes corrosion in refineries. The determination of total acid number (TAN) in petroleum
products is recommended by ASTM standard D 664-04, based on potentiometric titration in non aqueous media. As an alternative to official methodology, in this work, TAN in atmospheric residue and vacuum residue samples of petroleum
distillation was determined using middle infrared spectroscopy with attenuated total reflection (ATR-FTIR) in association to chemometric methods. For the development of calibration models, at first, was made the detection of outliers samples using principal component analysis (PCA). After, the selection of samples for calibration and prediction set was made by hierarchical cluster analysis (HCA). Calibration set
was consisted of 44 samples and prediction one by 13, summarizing 16 samples of atmospheric residue and 41 samples of vacuum residue. Calibration models were
developed using three variable selection models: method of interval partial least squares (iPLS), method of synergy partial least squares (siPLS) and method of backward interval partial least squares (biPLS). Different treatments and preprocessing
were evaluated for models development also. The treatment based on first derivative with Savitzky-Golay filter and the data centered in the media produced the best models using biPLS. Spectra were divided in 20 intervals and, finally, 5 intervals were combined (2992 till 2826, 1823 till 1657, 1656 till 1490, 1489 till 1323 and 821 till 655 cm-1). This model produced a root mean square error of cross-validation (RMSECV) of 0.1649 mg KOH g-1 and a root mean square error of prediction (RMSEP) of 0.1642 mg KOH g-1, showing a coefficient of determination of 0.9819 and a medium error of 22.5%. The analytical method for TAN determination allows fast analysis and relatively low cost in these samples, being of
easy application in industry environment.