dc.contributorSoares, José Mario Doleys
dc.contributorhttp://lattes.cnpq.br/2986137592706630
dc.contributorRizzatti, Eduardo
dc.contributorhttp://lattes.cnpq.br/2907271596071103
dc.contributorRamires, Marcus Vinicius Veleda
dc.contributorhttp://lattes.cnpq.br/5038681211194894
dc.creatorPasquali, Ivair
dc.date.accessioned2007-07-10
dc.date.available2007-07-10
dc.date.created2007-07-10
dc.date.issued2007-02-28
dc.identifierPASQUALI, Ivair. Influence of the type of mortar bedding to the compretion resistence of small structure mansonry walls. 2007. 140 f. Dissertação (Mestrado em Engenharia Civil) - Universidade Federal de Santa Maria, Santa Maria, 2007.
dc.identifierhttp://repositorio.ufsm.br/handle/1/7887
dc.description.abstractThe present work has as its main objective to analyze the influence of the mortar bedding in the resistance to compression of small structure masonry walls. For this study were used two types of ceramic blocks (bulk wall blocks and hollow wall blocks), three types of mortar (2 Mpa, 4 Mpa and 10 Mpa) and two types of mortar bedding: whole bedding when the blocks are bedded with mortar in all contact surfaces and longitudinal bedding when the blocks are bedded with only two longitudinal lines (external thickness of the block). Two types dos blocks and mortar were individually characterized through various specific norms tests and afterwards 72 small walls were built. The small walls were built with the pattern dimension of 140 mm x 450 mm x 900 mm being 4 rows in height + u low channel length of one and a half blocks and width of one block. The blocks at the extremities of the walls were already mounted bathed in a cement paste. The analyses of the results show that for the 2 Mpa mortar, bulk wall block and whole bedding the average resistance is 4.68 Mpa and for the 10 Mpa mortar considering the same conditions the average resistance increases to 6.57 Mpa (40.4%). For the 2 Mpa mortar, hollow wall blocks and longitudinal mortar bedding the average resistance is 2.9 Mpa and for the 10 Mpa mortar, considering the same conditions the average resistance increased to 3.33 Mpa (14.8%)
dc.publisherUniversidade Federal de Santa Maria
dc.publisherBR
dc.publisherEngenharia Civil
dc.publisherUFSM
dc.publisherPrograma de Pós-Graduação em Engenharia Civil
dc.rightsAcesso Aberto
dc.subjectAlvenaria estrutural
dc.subjectArgamassa
dc.subjectAssentamento
dc.subjectBloco cerâmico
dc.subjectPequenas paredes
dc.subjectStructural masonry
dc.subjectMortar
dc.subjectMortar bedding
dc.subjectCeramic block
dc.subjectSmall walls
dc.titleInfluência do tipo de argamassamento na resistência à compressão de pequenas paredes de alvenaria estrutural cerâmica
dc.typeDissertação


Este ítem pertenece a la siguiente institución