dc.contributor | Grehs, Renésio Armindo | |
dc.contributor | http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4229991T6 | |
dc.contributor | Ferrazzo, Vilmar Antonio | |
dc.contributor | http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4790212T7 | |
dc.contributor | Manfio, Angelo Pegoraro | |
dc.contributor | http://lattes.cnpq.br/1324005921607998 | |
dc.creator | Miotti, Fabrício Lamberti | |
dc.date.accessioned | 2016-11-04 | |
dc.date.available | 2016-11-04 | |
dc.date.created | 2016-11-04 | |
dc.date.issued | 2016-07-29 | |
dc.identifier | MIOTTI, Fabrício Lamberti. STUDY OF THE EFFECTS OF STERILIZATION AND REUSE OF MINI-SCREWS, UP TO THREE TIMES, ON TORQUE REQUIRED TO FRACTURE. 2016. 47 f. Dissertação (Mestrado em Odontologia) - Universidade Federal de Santa Maria, Santa Maria, 2016. | |
dc.identifier | http://repositorio.ufsm.br/handle/1/6183 | |
dc.description.abstract | Orthodontists have been reusing mini-implants that fail after installation or that will be
inserted in a new place due to mechanic needs in order to optimize clinical time. The
aim of this study was to simulate the reuse of mini-implants up to three times and
evaluate their potential weakness. We used 48 screws (Morelli, Sorocaba, Brazil), which
were divided into four groups: C= Control, G1 = one reuse, G2 = two reuse, G3 = three
reuse. In order to simulate inserts in patients mouths, we used pig iliac bone. After we
insert screws on bone specimen, we removed, cleaned, and sterilized them by
autoclaving. The guide at the machine we used allowed us to standardize installations.
After all groups were submitted to their reuse periods, mini-implants were submitted to
fracture, and the strongest force necessary to break them was measured by a digital
axial torquemeter. We used bovine tibia specimens for fracture, because of its greater
bone cortical and bone density. We used One Way ANOVA (Bonferroni post-hoc) to
compare means of each group. Results showed differences statistically significant
between G3 and the other groups. All mini-implants needed strength higher than
recommended by the literature to be inserted into patients, even though we found
differences in fracture resistance between groups. | |
dc.publisher | Universidade Federal de Santa Maria | |
dc.publisher | BR | |
dc.publisher | Odontologia | |
dc.publisher | UFSM | |
dc.publisher | Programa de Pós-Graduação em Ciências Odontológicas | |
dc.rights | Acesso Aberto | |
dc.subject | Ortodontia | |
dc.subject | Procedimentos de ancoragem ortodôntica | |
dc.subject | Reciclagem | |
dc.subject | Orthodontics | |
dc.subject | Orthodontic anchorage procedure | |
dc.subject | Recycling | |
dc.title | Avaliação do torque de fratura de mini-implantes submetidos à até três reutilizações | |
dc.type | Dissertação | |