dc.contributorCardoso Junior, Ghendy
dc.contributorhttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4770600A7
dc.contributorMariotto, Lenois
dc.contributorhttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4787711P4
dc.contributorFerreira, Gustavo Dorneles
dc.contributorhttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4214434U8
dc.creatorMuraro, Matias Rossato
dc.date.accessioned2017-05-30
dc.date.accessioned2019-05-24T19:49:07Z
dc.date.available2017-05-30
dc.date.available2019-05-24T19:49:07Z
dc.date.created2017-05-30
dc.date.issued2014-02-27
dc.identifierMURARO, Matias Rossato. Proposal interconnection protection for islanding detection in distributed generation systems. 2014. 154 f. Dissertação (Mestrado em Engenharia Elétrica) - Universidade Federal de Santa Maria, Santa Maria, 2014.
dc.identifierhttp://repositorio.ufsm.br/handle/1/8538
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/2836860
dc.description.abstractThis work presents a methodology for detecting islanding in distributed generation systems - DG - which use internal combustion engines as primary sources and synchronous generators connected directly to grid. The proposed method considers the characteristics of this type of DG, and is based on the analyses of the injected power and voltage level to disable or enable the under/over frequency protection. The proposed protection scheme considers the frequency as the main electrical signal, and has three stages: the first stage is disabled when power injected oscillations are detected, in the others cases, the stage is enabled; the second stage is normally disabled, it will be enabled when a balanced voltage is detected after a unbalanced voltage condition and the third stage is normally enabled and is used to detect large frequency deviations. The proposed protection was tested over diferentes events, islanding with different load and generation levels, temporary short-circuit and islanding during short-circuit. The results show the efficiency and reliability in detecting islanding, presenting no false detections.
dc.publisherUniversidade Federal de Santa Maria
dc.publisherBR
dc.publisherEngenharia Elétrica
dc.publisherUFSM
dc.publisherPrograma de Pós-Graduação em Engenharia Elétrica
dc.rightsAcesso Aberto
dc.subjectGeração distribuída
dc.subjectIlhamento
dc.subjectSubfrequência e sobrefrequência
dc.subjectOscilação de potência
dc.subjectDistributed generation
dc.subjectIslanding
dc.subjectUnderfrequency and overfrequency
dc.subjectPower swing
dc.titleUma proposta de interconexão de proteções para detecção de ilhamento em sistemas de geração distribuída
dc.typeTesis