dc.contributorCichoski, Alexandre José
dc.contributorhttp://lattes.cnpq.br/8253591322909707
dc.contributorTerra, Nelcindo Nascimento
dc.contributorhttp://lattes.cnpq.br/4871318542229253
dc.contributorBizzi, Cezar Augusto
dc.contributorhttp://lattes.cnpq.br/2975070149037006
dc.contributorHuber, Eduardo
dc.contributorhttp://lattes.cnpq.br/9147168410009655
dc.creatorFlores, Diego Rafael Martins
dc.date.accessioned2016-10-03
dc.date.available2016-10-03
dc.date.created2016-10-03
dc.date.issued2016-08-02
dc.identifierFLORES, Diego Rafael Martins. Ultrasound and electrolyzed water application in pre chilling of chicken breast (Pectoralis major). 2016. 105 f. Dissertação (Mestrado em Ciência e Tecnologia dos Alimentos) - Universidade Federal de Santa Maria, Santa Maria, 2016.
dc.identifierhttp://repositorio.ufsm.br/handle/1/5800
dc.description.abstractThe chicken meat has characteristics that has currently attracted the consumer, leading to increased industrial production, which seeks better production conditions. Ultrasound (US) and the electrolyzed water (EW) are technologies that enable improvements in traditional processes employed by slaughter houses. Its features allow it to have a reduction in water consumption and improvements in features such as the microbiological safety and tenderness. However, further studies are briefly describing possible oxidative effects on meat, especially chicken. Descriptions of the application of US pre-chilling showed improvements compared to applications without this technology. US demonstrated assist heat transfer, resulting in a more homogeneous and rapid cooling, especially in frequencies of 130 kHz. Combinations with EW and US have shown an intensification of cooling. These applications have a limit of time, and observed a reduction in the ability to cool the parts analyzed when this limit is exceeded. The US and EW applications also reported reductions in the initial microbial load, without that there was the initiation of oxidative processes, changes in glycolysis and the beginning of the muscle of the conversion process in the meat. In this pieces were not analyzed changes in its tenderness. Characterizing a prospective use of both technologies in larger and industrial scales.
dc.publisherUniversidade Federal de Santa Maria
dc.publisherBR
dc.publisherCiência e Tecnologia dos Alimentos
dc.publisherUFSM
dc.publisherPrograma de Pós-Graduação em Ciência e Tecnologia dos Alimentos
dc.rightsAcesso Aberto
dc.subjectUltrassom
dc.subjectÁgua eletrolisada
dc.subjectPré-resfriamento
dc.subjectQualidade
dc.subjectUltrasound
dc.subjectElectrolyzed water
dc.subjectPre-chilling
dc.subjectQuality
dc.titleAplicação de ultrassom e água eletrolisada no pré-resfriamento de peito de frango (Pectoralis major)
dc.typeDissertação


Este ítem pertenece a la siguiente institución