dc.description.abstractFeedback control systems have been used to move the muscles and joints of the limbs of paraplegic patients. The feedback signal, related to the knee joint angle, can be obtained by using an electrogoniometer. However, the use of accelerometers can help the measurements due the facility of adhering these devices to the skin. Accelerometers are also very suitable for these applications due their small dimensions and weight. In this paper a new method for designing a control system that can vary the knee joint angle using Functional Electrical Stimulation (FES) is presented, as well as a simulation with parameters values available in the literature. The nonlinear control system was represented by a Takagi-Sugeno fuzzy model and the feedback signals were obtained by using accelerometers. The design method considered all plant nonlinearities and was efficient and reliable to control the leg position of a paraplegic patient with the angle of the knee ranging from 0° to 30°, considering electric stimulation at the quadriceps muscle. The proposed method is viable and offers a new alternative for designing control systems of the knee joint angle using more comfortable sensors for the patients.
dc.languageeng
dc.languagepor
dc.relationRevista Brasileira de Engenharia Biomédica
dc.relation0,179
dc.rightsAcesso aberto
dc.sourceScopus
dc.subjectAccelerometers
dc.subjectFunctional electrical stimulation
dc.subjectNonlinear control
dc.subjectTakagi-sugeno fuzzy
dc.subjectDerivative feedbacks
dc.subjectDesign method
dc.subjectDesigning control system
dc.subjectElectric stimulation
dc.subjectElectrogoniometers
dc.subjectFeedback signal
dc.subjectKnee-joint angle
dc.subjectNon linear control
dc.subjectParaplegic patients
dc.subjectTakagi Sugeno fuzzy models
dc.subjectTakagi-sugeno
dc.subjectAdaptive control systems
dc.subjectControl nonlinearities
dc.subjectElectrophysiology
dc.subjectElectrotherapeutics
dc.subjectFeedback control
dc.subjectFunctional electric stimulation
dc.subjectMuscle
dc.subjectNonlinear feedback
dc.subjectWell stimulation
dc.subjectJoints (anatomy)
dc.titleRealimentação derivativa e modelo fuzzy Takagi-Sugeno paracontrole da articulação do joelho de pacientes paraplégicos com o uso de acelerômetros