dc.contributorUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-20T15:13:51Z
dc.date.available2014-05-20T15:13:51Z
dc.date.created2014-05-20T15:13:51Z
dc.date.issued1999-09-01
dc.identifierActa Cirúrgica Brasileira. Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia, v. 14, n. 3, p. 00-00, 1999.
dc.identifier0102-8650
dc.identifierhttp://hdl.handle.net/11449/28968
dc.identifier10.1590/S0102-86501999000300009
dc.identifierS0102-86501999000300009
dc.identifier8727897080522289
dc.identifier9919910234219937
dc.description.abstractO presente estudo teve por objetivo padronizar modelo experimental de estimulação cardíaca artificial atrial em coelhos. Foram utilizados 20 coelhos raça Norfolk-2000 de ambos os sexos com peso mínimo de 2200g. Após anestesia endovenosa com pentobarbital(30mg/Kg), foi dissecada a veia jugular externa esquerda e introduzido eletrodo EthiconÒ especialmente preparado, até átrio direito via veia cava esquerda. Foram realizadas leituras dos parâmetros elétricos(ondaP, resistência e limiar de comando) no ato cirúrgico e com 7, 14 e 21 dias denominados M1,M2, M3 e M4 respectivamente. Observamos diferença significativa em todos as variáveis analisadas entre M1 e demais momentos. Os resultados são compatíveis com o que se conhece de estimulação cardíaca artificial em outras espécies animais e no homem. O presente modelo mostrou ser viável para estudos de estimulação cardíaca artificial.
dc.description.abstractThe aim of the present study was to standardize an experimental model for artificial atrial heart pacing in rabbits. Twenty rabbits(Norfolk-2000, both sexes with minimum weigth of 2200g) were studied. After endovenous anesthesia with pentobarbital sodium(30mg/Kg) the external jugular vein was dissected and a pacemaker lead(Ethiconâ ) was introduced through left cava vein until the rigth atriun. The eletric parameters(P wave, resistance and threshold) were accomplished at surgical time and at 7, 14 and 21 post-operative day. These experimental moments were denominated M1, M2, M3 and M4 respectively. The statistical analisys showed significant difference between M1 and all others experimental moments. The results are compatible with the actual knowlodge of artificial heart pacing in others animal species and in human beings. The present model showed to be viable for artificial pacing studies.
dc.languagepor
dc.publisherSociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia
dc.relationActa Cirúrgica Brasileira
dc.relation0.933
dc.relation0,395
dc.rightsAcesso aberto
dc.sourceSciELO
dc.subjectEstimulação cardíaca artificial
dc.subjectMarca-passo artificial
dc.subjectCirurgia experimental
dc.subjectCardiac pacing artificial
dc.subjectPacemaker artificial
dc.subjectExperimental surgery
dc.titlePadronização de modelo experimental para estimulação elétrica artificial atrial em coelhos
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución