Artículo de revista
A fractal time thermal model for predicting the surface temperature of air-cooled cylindrical Li-ion cells based on experimental measurements
Fecha
2016Registro en:
Journal of Power Sources 306 (2016) 636-645
dx.doi.org/10.1016/j.jpowsour.2015.12.037
Autor
Reyes Marambio, Jorge
Moser, Francisco
Gana, Felipe
Severino, Bernardo
Calderón Muñoz, Williams
Palma Behnke, Rodrigo
Estévez Valencia, Pablo
Orchard Concha, Marcos
Cortés, Marcelo
Institución
Resumen
This paper presents a experimentally-validated fractal time thermal model to describe the discharge and
cooling down processes of air-cooled cylindrical Lithium-ion cells. Three cases were studied, a spatially
isolated single cell under natural convection and two spatial configurations of modules with forced air
cooling: staggered and aligned arrays with 30 and 25 cells respectively. Surface temperature measurements
for discharge processes were obtained in a single cell at 1 C, 2 C and 3 C discharge rates, and in the
two arrays at 1 C discharge rate. In the modules, surface temperature measurements were obtained for
selected cells at specific inlet cooling air speeds. The fractal time energy equation captures the anomalous
temperature relaxation and describes the cell surface temperature using a stretched exponential model.
Stretched exponential temperature models of cell surface temperature show a better agreement with
experimental measurements than pure exponential temperature models. Cells closer to the horizontal
side walls have a better heat dissipation than the cells along the centerline of the module. The high
prediction capabilities of the fractal time energy equation are useful in new design approaches of thermal
control strategies of modules and packs, and to develop more efficient signal-correction algorithms in
multipoint temperature measurement technologies in Li-ion batteries.