dc.contributor | Trillos, Carlos Enrique | |
dc.creator | García Lozada, Diana G. | |
dc.date.accessioned | 2010-04-20T18:29:53Z | |
dc.date.available | 2010-04-20T18:29:53Z | |
dc.date.created | 2010-04-20T18:29:53Z | |
dc.date.issued | 2010 | |
dc.identifier | TEME 0061 2009 | |
dc.identifier | http://repository.urosario.edu.co/handle/10336/1801 | |
dc.description.abstract | Introduction: The gold standard for refractive error is retinoscopy. When teachers of optometry evaluate students, they accept a difference of ±0. 50D in refraction but it has not been evaluated statistically nor whether it is appropriate for low and high ametropias. The objective was to quantify the degree of interobserver agreement in static retinoscopy between teachers and students, for low and high ametropias. Methodology: Study of agreement between 4 observers in 40 eyes, 20 with high ametropias and 20 with low errors, non-probability sampling. Statistical analysis with intraclass correlation coefficient, reliability 95%, power 90%, and graphic method of agreement limits to 95%. Results: Concordance for the spherical equivalent between teachers was 0. 96 and between students was 0. 56. In students concordance was 0. 89 for low refractive errors and between teachers was 0. 96 for high defects. Concordance among four examiners was 0. 78, in low defects was 0. 86 and in high ametropias was 0. 67. Margin of error between teachers was ±0. 87D and between students ±3. 15D. In low defects ±0. 61D for teachers and ±0. 80D for students; in high errors ±1. 10D and ±4. 22D, respectively. Discussion: There was a higher reliability in retinoscopy between experienced professionals. The concordance was compared between teachers and students, and was founded less matching that described by other studies comparing between professionals, despite being chosen by their good grades. Must be developed teaching strategies to reduce the margins of error obtained and to improve concordance between teachers and students. | |
dc.language | spa | |
dc.publisher | Universidad del Rosario | |
dc.publisher | Facultad de medicina | |
dc.rights | http://creativecommons.org/licenses/by-nc-nd/2.5/co/ | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights | Abierto (Texto completo) | |
dc.rights | Atribución-NoComercial-SinDerivadas 2.5 Colombia | |
dc.rights | EL AUTOR, manifiesta que la obra objeto de la presente autorización es original y la realizó sin violar o usurpar derechos de autor de terceros, por lo tanto la obra es de exclusiva autoría y tiene la titularidad sobre la misma.
PARÁGRAFO: En caso de presentarse cualquier reclamación o acción
por parte de un tercero en cuanto a los derechos de autor sobre
la obra en cuestión, EL AUTOR, asumirá toda la responsabilidad, y saldrá en defensa de los derechos aquí autorizados; para todos los efectos la universidad actúa como un tercero de buena fe.
EL AUTOR, autoriza a LA UNIVERSIDAD DEL ROSARIO, para que en los términos establecidos en la Ley 23 de 1982, Ley 44 de 1993, Decisión andina 351 de 1993, Decreto 460 de 1995 y demás normas generales sobre la materia, utilice y use la obra objeto de la presente autorización. | |
dc.source | instname:Universidad del Rosario | |
dc.source | reponame:Repositorio Institucional EdocUR | |
dc.subject | optometría | |
dc.subject | retinoscopía | |
dc.subject | errores de refracción | |
dc.subject | reproducibilidad de resultados | |
dc.subject | variaciones dependientes del observador | |
dc.title | Retinoscopía estática: variabilidad interobservadores entre docentes y estudiantes de optometría en una institución universitaria de Bogotá D.C. | |
dc.type | bachelorThesis | |