dc.descriptionThere are many nickel-titanium alloy wires available in the market.Nevertheless not all of them possess the ideal characteristicsof shape memory and super-elasticity to be used in orthodontictreatment. The aim of the present study was to find austeniticfinal temperature of these archwires so as to determine thetransformation phase in order to better use them in orthodontics.Methods: Eleven nickel-titanium orthodontic wires were selected.Transformation phase was assessed using differential scanningcalorimetry method. Conclusions: The present study illustrateshow some orthodontic Ni-Ti wires elicit results contrary to thoseadvertised.en-US
dc.formatapplication/pdf
dc.languagespa
dc.publisherFacultad de Odontologíaes-ES
dc.relationhttp://ojs.unam.mx/index.php/rom/article/view/56917/50501
dc.rights##submission.copyrightStatement##es-ES
dc.sourceRevista Odontológica Mexicana; Vol 20, No 3-INGes-ES
dc.source1870-199X
dc.subjecten-US
dc.subjectAustenitic fi nal point, nickel-titanium alloys, phase transformation, differential scanning, calorimetry.en-US
dc.titleClinical importance of austenitic fi nal point in the selection of nickel-titanium alloys for application in orthodontic-use archesen-US