dc.contributor | | en-US |
dc.creator | Orozco Barreto, Rossany | |
dc.creator | Alvarez Gayosso, Carlos | |
dc.creator | Guerrero Ibarra, Jorge | |
dc.date | 2015-11-05 | |
dc.date.accessioned | 2018-03-16T15:59:25Z | |
dc.date.available | 2018-03-16T15:59:25Z | |
dc.identifier | http://ojs.unam.mx/index.php/rom/article/view/52998 | |
dc.identifier.uri | http://repositorioslatinoamericanos.uchile.cl/handle/2250/1204174 | |
dc.description | Objective: To determine the thickness of dental tissue through which Prime Dent Resin® might exhibit light-polymerization with minimum shrinkage and suitable curing depth. Method: 80 laminae measuring 1, 2, 3 and 4 mm thickness were obtained from molars (20 laminae per group). Contraction was measured and resin shrinkage was calculated by polymerization (Visilux 2, 3M) though each lamina (60 s, 400 mW/cm2). Bonded-disk technique was used. Depth of curing tests were undertaken by measuring the thickness of polymerized resin according to ADA’s specifi cation number 27. A control group without dental tissue was prepared for both properties. Data were analyzed using ANOVA with Tukey test (p < 0.001). Results: Curing depth: curing depth decreased as thickness increased. All groups revealed statistically significant differences. The thickness that exhibited lesser shrinkage nonetheless meeting with suitable curing depth (ADA establishes minimum value of 1 mm) was the 3 mmgroup. Shrinkage: as thickness increased, shrinkage decreased; no statistically signifi cant difference was reported for groups 2 and 3 mm. Conclusions: According to obtained results, it is possible to polymerize through a 3 mm thickness, therefore polymerization is not recommended through a 4 mm depth. It will be necessary to obtain further mechanical properties using different thicknesses of dental tissue. | en-US |
dc.format | application/pdf | |
dc.language | spa | |
dc.publisher | Facultad de Odontología | es-ES |
dc.relation | http://ojs.unam.mx/index.php/rom/article/view/52998/47145 | |
dc.rights | ##submission.copyrightStatement## | es-ES |
dc.source | Revista Odontológica Mexicana; Vol 19, No 4-ING | es-ES |
dc.source | 1870-199X | |
dc.subject | | en-US |
dc.subject | Polymerization contraction, shrinkage, curing depth, light-curing resin, thickness of dental lamina, polymerization. | en-US |
dc.title | Light-polymerization of composite resins through different thicknesses of dental tissue | en-US |
dc.type | Artículos de revistas | |
dc.type | Artículos de revistas | |