Indoor radon and airborne particles

dc.creatorSegovia, N.; ININ. AP. Postal 18-1027, 11801 México, D.F. MEXICO
dc.creatorPonciano, G.; Department of Pharmacology, Faculty of Medicine, UNAM, 04510 México, D. F., México
dc.creatorRuiz, W.; ININ. AP. Postal 18-1027, 11801 México, D.F. MEXICO
dc.creatorGodínez, L.; Instituto de Geografía, UNAM, 04510 México, D.F., México
dc.date2012-05-09
dc.date.accessioned2018-03-16T15:53:53Z
dc.date.available2018-03-16T15:53:53Z
dc.identifierhttp://ojs.unam.mx/index.php/geofisica/article/view/39720
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1203400
dc.descriptionSe midieron las fluctuaciones de radón en casas del Estado de México y del Distrito Federal con la finalidad de evaluarfluctuaciones de corta duración. Para ello, se utilizaron detectores Honeywell A9000 A que registran el decaimiento alfa del radóny sus descendientes. Asimismo, se midieron los cambios en la concentración de partículas suspendidas utilizando un equipoPersonal Data-Logging Real-time Aerosol Monitor. Los resultados indican un valor promedio de radón intramuros de 22 Bq/m3con incrementos esencialmente en la madrugada, que alcanzaron valores hasta un orden de magnitud mayor que el promedio. Laspartículas suspendidas intramuros mostraron un valor promedio de 0.08 mg/m3. Experimentos en habitaciones cerradas con fumadoresmostraron una concentración de partículas suspendidas dependiente de la ventilación y del número de fumadores en elrecinto.es-ES
dc.descriptionDaily radon fluctuations were monitored in dwellings located in the State of Mexico and in Mexico City in order to assessthe expected fluctuations in a short term monitoring basis. The radon monitoring was performed with Honeywell A9000 A devicesthat record radon and daughters using silicon detectors. Airborne particle fluctuations were also determined using a Personal Data-Logging Real-time Aerosol Monitor. The results indicate an indoor radon average value of 22 Bq/m3. Discrete values one order ofmagnitude higher than the mean were observed, mainly between midnight and early morning. The airborne particles in the bedroomshowed daily average values of 0.08 mg/m3. Experiments with smokers indicated fluctuations in the airborne particle concentrationsthat depend on the ventilation and the number of smokers in the room.en-US
dc.formatapplication/pdf
dc.languagespa
dc.publisherInstituto de Geofísicaes-ES
dc.relationhttp://ojs.unam.mx/index.php/geofisica/article/view/39720/36145
dc.sourceGeofísica Internacional; Vol 41, No 3 (2002)es-ES
dc.source0016-7169
dc.subjectRadón intramuros, equipos automáticos, medidas de corta duración, partículas suspendidas, fumadores.es-ES
dc.subjectIndoor radon, automatic devices, short term monitoring, airborne particles, smoking.en-US