dc.creator | Segovia, N.; ININ. AP. Postal 18-1027, 11801 México, D.F. MEXICO | |
dc.creator | Ponciano, G.; Department of Pharmacology, Faculty of Medicine, UNAM, 04510 México, D. F., México | |
dc.creator | Ruiz, W.; ININ. AP. Postal 18-1027, 11801 México, D.F. MEXICO | |
dc.creator | Godínez, L.; Instituto de Geografía, UNAM, 04510 México, D.F., México | |
dc.date | 2012-05-09 | |
dc.date.accessioned | 2018-03-16T15:53:53Z | |
dc.date.available | 2018-03-16T15:53:53Z | |
dc.identifier | http://ojs.unam.mx/index.php/geofisica/article/view/39720 | |
dc.identifier.uri | http://repositorioslatinoamericanos.uchile.cl/handle/2250/1203400 | |
dc.description | Se midieron las fluctuaciones de radón en casas del Estado de México y del Distrito Federal con la finalidad de evaluarfluctuaciones de corta duración. Para ello, se utilizaron detectores Honeywell A9000 A que registran el decaimiento alfa del radóny sus descendientes. Asimismo, se midieron los cambios en la concentración de partículas suspendidas utilizando un equipoPersonal Data-Logging Real-time Aerosol Monitor. Los resultados indican un valor promedio de radón intramuros de 22 Bq/m3con incrementos esencialmente en la madrugada, que alcanzaron valores hasta un orden de magnitud mayor que el promedio. Laspartículas suspendidas intramuros mostraron un valor promedio de 0.08 mg/m3. Experimentos en habitaciones cerradas con fumadoresmostraron una concentración de partículas suspendidas dependiente de la ventilación y del número de fumadores en elrecinto. | es-ES |
dc.description | Daily radon fluctuations were monitored in dwellings located in the State of Mexico and in Mexico City in order to assessthe expected fluctuations in a short term monitoring basis. The radon monitoring was performed with Honeywell A9000 A devicesthat record radon and daughters using silicon detectors. Airborne particle fluctuations were also determined using a Personal Data-Logging Real-time Aerosol Monitor. The results indicate an indoor radon average value of 22 Bq/m3. Discrete values one order ofmagnitude higher than the mean were observed, mainly between midnight and early morning. The airborne particles in the bedroomshowed daily average values of 0.08 mg/m3. Experiments with smokers indicated fluctuations in the airborne particle concentrationsthat depend on the ventilation and the number of smokers in the room. | en-US |
dc.format | application/pdf | |
dc.language | spa | |
dc.publisher | Instituto de Geofísica | es-ES |
dc.relation | http://ojs.unam.mx/index.php/geofisica/article/view/39720/36145 | |
dc.source | Geofísica Internacional; Vol 41, No 3 (2002) | es-ES |
dc.source | 0016-7169 | |
dc.subject | Radón intramuros, equipos automáticos, medidas de corta duración, partículas suspendidas, fumadores. | es-ES |
dc.subject | Indoor radon, automatic devices, short term monitoring, airborne particles, smoking. | en-US |
dc.title | Indoor radon and airborne particles | es-ES |
dc.title | Indoor radon and airborne particles | en-US |
dc.type | Artículos de revistas | |
dc.type | Artículos de revistas |