Buscar
Mostrando ítems 1-10 de 1806
Rapid determination of zinc in foods by flow injection analysis with flame AAS using gradient calibration method
(2004-09-01)
A calibration method was developed using flow injection analysis (FI) with a Gradient Calibration Method (GCM). The method allows the rapid determination of zinc In foods (approximately 30 min) after treatment with ...
Simple and clean determination of tetracyclines by flow injection analysis
(Elsevier B. V., 2015-09-03)
An environmentally reliable analytical methodology was developed for direct quantification of tetracycline (TC) and oxytetracycline (OTC) using continuous flow injection analysis with spectrophotometric detection. The ...
Fast Determination of Ciclopirox in Pharmaceutical Products by Amperometry in Flow and Batch Injection Systems
(WILEY-V C H VERLAG GMBHWEINHEIM, 2012)
Amperometry coupled to flow injection analysis (FIA) and to batch injection analysis (BIA) was used for the rapid and precise quantification of ciclopirox olamine in pharmaceutical products. The favourable hydrodynamic ...
New representation of PV buses in the current injection Newton power flow
(2017-09-01)
This paper presents a comparative analysis of the influence of PV bus representation on the convergence characteristics of the Newton-Raphson Current Injection method. The methods used for solving the power flow problem ...
Sequential spectrophotometric determination of chromium(III) and chromium(VI) using flow injection analysis
(1985-12-01)
A flow injection analysis (FIA) procedure for the speciation of Cr(III) and Cr(VI) using the 1,5-diphenylcarbazide (DPC) method is presented. As Cr(III) does not interfere in the Cr(VI) - DPC reaction, both Cr(VI) and total ...
Determination of sulfate in ethanol fuel using an electrode chemically modified with polypyrrole by flow injection analysis
(2010)
In this work, an electrode chemically modified with polypyrrole (PCME) was employed for determination of sulfate in ethanol fuel using a FIA system. The PCME was prepared by polymerization of pyrrole at a glassy carbon ...
Flow-injection spectrophotometric determination of dipyrone in pharmaceutical formulations using ammonium molybdate as chromogenic reagent
(Taylor & Francis Inc, 2005-01-01)
A simple and rapid flow-injection spectrophotometric method is reported for the determination of dipyrone in pharmaceutical formulations. The method is based on the reaction of dipyrone with ammonium molybdate in acidic ...
Use of a carbon paste electrode modified with spinel-type manganese oxide as a potentiometric sensor for lithium ions in flow injection analysis
(Wiley-Blackwell, 2004-04-01)
A potentiometric sensor constructed from a mixture of 25% (m/m) spinel-type manganese oxide (lambda-MnO2), 50% (m/m) graphite powder and 25% (m/m) mineral oil is used for the determination of lithium ions in a flow injection ...
Use of a carbon paste electrode modified with spinel-type manganese oxide as a potentiometric sensor for lithium ions in flow injection analysis
(Wiley-Blackwell, 2004-04-01)
A potentiometric sensor constructed from a mixture of 25% (m/m) spinel-type manganese oxide (lambda-MnO2), 50% (m/m) graphite powder and 25% (m/m) mineral oil is used for the determination of lithium ions in a flow injection ...
Development of a potentiometric flow cell with a stainless steel electrode for pH measurements. Determination of acid mixtures using flow injection analysis
(Elsevier Science BvAmsterdamHolanda, 2000)