Determination of sulfate in ethanol fuel using an electrode chemically modified with polypyrrole by flow injection analysis
Fecha
2010Registro en:
Journal of Biofuels, v. 1, n. 2, p. 220-227, 2010.
0976-3015
10.5958/j.0976-3015.1.2.027
6167204386206414
8477732400095433
0072173018005712
1923726000036625
1183672452248157
0000-0002-2296-1393
Autor
Universidade Estadual Paulista (Unesp)
Institución
Resumen
In this work, an electrode chemically modified with polypyrrole (PCME) was employed for determination of sulfate in ethanol fuel using a FIA system. The PCME was prepared by polymerization of pyrrole at a glassy carbon electrode by means of cyclic voltammetry technique. An analytical curve from 1.0 x 10−5 to 8.0 x 10−5 mol L−1 was obtained in flow injection system based on the PCME. An amperometric sensibility of 2.3 x 10−3 A mol−1 L and a detection limit of 2.5 x 10−6 mol L−1 were achieved. The proposed method was employed for determination of sulfate ions in commercial samples of ethanol fuel. The results were in good agreement with those obtained by the ionic chromatographic method.