Buscar
Mostrando ítems 1-10 de 345
Quality of Life, Satisfaction, Occlusal Force, and Halitosis after Direct and Indirect Relining of Inferior Complete Dentures
(2022-02-01)
Objective The aim of this study was to compare the direct relining technique with the indirect relining technique in relation to quality of life, satisfaction with the relining, occlusal force, and halitosis of users of ...
Effect of reline material and denture base surface treatment on the impact strength of a denture base acrylic resin
(Wiley-Blackwell Publishing, Inc, 2010-03-01)
Objective:In this study, the effect of relining and surface treatment on the impact strength (IS) of a heat-polymerising denture base acrylic resin (Lucitone 550-L) was evaluated.Materials and methods:Rectangular bars of ...
Impact strength of denture base and reline acrylic resins subjected to long-term water immersion
(2011-05-13)
Water may influence the mechanical properties of the acrylic resins. Thus, the effect of water storage on the impact strength (IS) of one denture base (Lucitone 550 - L) and four reline resins (Tokuyama Rebase II - T; ...
Impact strength of denture base and reline acrylic resins subjected to long-term water immersion
(2011-05-13)
Water may influence the mechanical properties of the acrylic resins. Thus, the effect of water storage on the impact strength (IS) of one denture base (Lucitone 550 - L) and four reline resins (Tokuyama Rebase II - T; ...
Influence of thermal and mechanical stresses on the strength of intact and relined denture bases
(Mosby, Inc, 2006-07-01)
Statement of problem. Denture bases may become increasingly weaker as a result of thermal stress and flexural cyclic loading. Information regarding this potential problem and its relationship to the denture base reline is ...
Bonding strength between a hard chairside reline resin and a denture base material as influenced by surface treatment
(Blackwell Publishing, 2001-12-01)
Direct relining of dentures made with hard chairside reline resins is faster than laboratory-processed reline systems and the patient is not without the prosthesis for the time necessary to perform the laboratory procedures. ...
Bonding strength between a hard chairside reline resin and a denture base material as influenced by surface treatment
(Blackwell Publishing, 2001-12-01)
Direct relining of dentures made with hard chairside reline resins is faster than laboratory-processed reline systems and the patient is not without the prosthesis for the time necessary to perform the laboratory procedures. ...
Color stability of relined dentures after chemical disinfection. A randomised clinical trial
(Elsevier B.V., 2011-12-01)
Background: This randomised clinical study evaluated the effect of chemical disinfection with sodium perborate or chlorhexidine on the color stability of a hard chairside reline resin during six months.Methods: Hard chairside ...
Effect of microwave disinfection procedures on torsional bond strengths of two hard chairside denture reline materials
(2006-11-01)
Purpose: This study evaluated the potential effects of denture base resin water storage time and an effective denture disinfection method (microwave irradiation at 650 W for 6 minutes) on the torsional bond strength between ...
Effect of microwave disinfection procedures on torsional bond strengths of two hard chairside denture reline materials
(2006-11-01)
Purpose: This study evaluated the potential effects of denture base resin water storage time and an effective denture disinfection method (microwave irradiation at 650 W for 6 minutes) on the torsional bond strength between ...