Buscar
Mostrando ítems 1-10 de 90
Numerical Study of the Seismic Efficiency of Buckling-Restrained Braces for Near and Far-Fault Inputs
(Bentham Science Publishers, 2015-05)
Buckling-restrained braces are commonly installed in building structures as concentric diagonal or chevron braces to protect the main construction from seismic actions. These elements have shown repeatedly their usefulness ...
Technical and economic analysis of design for performance of buildings with steel structure using concentric bracingsAnálisis técnico y económico del diseño por desempeño de edificios con estructura de acero utilizando arriostramientos concéntricos
(Universidad Centroccidental Lisandro Alvarado - Decanato de Ingeniería Civil, 2019)
Demand for material in regular steel structures with and without braces in seismic zone in high risk according to the Standard Covenin 1618-1998Demanda de material en estructuras regulares de acero con y sin arriostramientos en zona sísmica de riesgo elevado según Norma Covenin 1618- 1998
(Universidad Centroccidental Lisandro Alvarado - Decanato de Ingeniería Civil, 2015)
Stability and minimum lateral bracing for stepped columns with semi-rigid connections including shear effects: ii) verification and examples
(Universidad Nacional de Colombia Sede Medellín, 2012)
The elastic stability analysis of single-stepped columns with sidesway totally inhibited, partially inhibited, and uninhibited subjected to concentrated axial loads located at the ends and at the intermediate joint including ...
Assessment of the Seismic Behavior of Selective Storage Racks Subjected to Chilean Earthquakes
(MDPI, 2020)
A seismic performance evaluation of selective storage racks subjected to Chilean Earthquakes was conducted using nonlinear pushover and nonlinear dynamic time-history analyses. Nine seismic records with two horizontal ...
Analytical Investigation of the Structural Fuse Concept
(2006-06-28)
Passive energy devices (PED) are useful to enhance structural performance by reducing seismically induced structural damage. Metallic dampers are one such PED. When they are designed such that all damage is concentrated ...
Seismic Design of Multi-story Buildings with Metallic Structural Fuses
(2006-06-28)
Seismic design relies on inelastic deformations through hysteretic behavior. However, this translates into damage on structural elements, permanent system deformations following an earthquake, and possibly high cost for ...
Investigation of the Structural Fuse Concept
(2005-06-26)
Passive energy dissipation (PED devices have been implemented to enhance structural performance by reducing seismically induced structural damage. In this paper metallic dampers are defined to be structural fuses (SF) when ...