Determination of Cu, Ni and Pb in Aqueous Medium by FAAS after Pre-Concentration on 2-Aminothiazole Modified Silica Gel
(2004-08-30)
This work describes the synthesis and characterization of 2-aminothiazole modified silica gel (SiAT), and the results of a study of the adsorption and pre-concentration (in batch and using a flow-injection system coupled ...
Determination of Cu, Ni and Pb in Aqueous Medium by FAAS after Pre-Concentration on 2-Aminothiazole Modified Silica Gel
(2004-08-30)
This work describes the synthesis and characterization of 2-aminothiazole modified silica gel (SiAT), and the results of a study of the adsorption and pre-concentration (in batch and using a flow-injection system coupled ...
Adsorption of dihydrogen phosphate ion on platinum electrodes in aqueous media monitored by probe-beam deflection
(2005-06-07)
Probe-beam deflection (PBD) was used to monitor concentration gradients of anions adjacent to the surface of a platinum electrode in acidic aqueous media containing H3PO4. PBD can measure the potential-dependent extent of ...
Adsorption of dihydrogen phosphate ion on platinum electrodes in aqueous media monitored by probe-beam deflection
(2005-06-07)
Probe-beam deflection (PBD) was used to monitor concentration gradients of anions adjacent to the surface of a platinum electrode in acidic aqueous media containing H3PO4. PBD can measure the potential-dependent extent of ...
Investigation of phosphorus atomization using high-resolution continuum source electrothermal atomic absorption spectrometry
(2007)
The atomization of phosphorus in electrothermal atomic absorption spectrometry has been investigated using a high-resolution continuum source atomic absorption spectrometer and atomization from a graphite platform as well ...
Determination of cadmium in river water samples by flame AAS after on-line preconcentration in mini-column packed with 2-aminothiazole-modified silica gel
(2004-07-01)
A rapid and sensitive method was developed to determine trace levels of Cd2+ ions in an aqueous medium by flame atomic absorption spectrometry, using on-line preconcentration in a mini-column packed with 100 mg of ...
Determination of cadmium in river water samples by flame AAS after on-line preconcentration in mini-column packed with 2-aminothiazole-modified silica gel
(2004-07-01)
A rapid and sensitive method was developed to determine trace levels of Cd2+ ions in an aqueous medium by flame atomic absorption spectrometry, using on-line preconcentration in a mini-column packed with 100 mg of ...