Artigo
Determination of Cu, Ni and Pb in Aqueous Medium by FAAS after Pre-Concentration on 2-Aminothiazole Modified Silica Gel
Fecha
2004-08-30Registro en:
Journal of the Brazilian Chemical Society, v. 15, n. 3, p. 366-371, 2004.
0103-5053
10.1590/S0103-50532004000300005
S0103-50532004000300005
WOS:000221883800004
2-s2.0-4143086075
2-s2.0-4143086075.pdf
6981448637456391
Autor
Universidade Estadual Paulista (Unesp)
Resumen
This work describes the synthesis and characterization of 2-aminothiazole modified silica gel (SiAT), and the results of a study of the adsorption and pre-concentration (in batch and using a flow-injection system coupled to an absorption atomic spectrometer) of Cu(II), Ni(II) and Pb(II) in aqueous medium. The adsorption capacities for each metal ions in mmol g -1 were: Cu(II)= 1.18, Ni(II)= 1.15 and Pb(II)= 1.10. The results obtained in the flow experiments showed a recovery of practically 100% of the metal ions adsorbed in a mini-column packed with 100 mg of SiAT, using 100 μL of 2.0 mol L -1 HCl solution as eluent. The sorption-desorption of the metal ions made possible the application of a flow-injection system for the pre-concentration and quantification by FAAS of metal ions at trace level in natural water samples digested and not digest by an oxidizing UV photolysis.