Buscar
Mostrando ítems 1-10 de 46
Distortional buckling of simple lipped channel in bending results of the experimental analysis versus direct strength methods
(2006-12-01)
Cold-formed steel members are subject to failure caused by buckling, normally under loads smaller than those corresponding to partial or total yielding of the cross section. The buckling of members in bending can be ...
Distortional buckling of simple lipped channel in bending results of the experimental analysis versus direct strength methods
(2006-12-01)
Cold-formed steel members are subject to failure caused by buckling, normally under loads smaller than those corresponding to partial or total yielding of the cross section. The buckling of members in bending can be ...
DSM-based prediction of distortional failure loads of cold-formed steel columns at elevated temperaturesResistência segundo MRD de colunas de aço em perfil formado a frio sob modo de falha distorcional em altas temperaturas
(Universidade Federal do Rio de JaneiroBrasilInstituto Alberto Luiz Coimbra de Pós-Graduação e Pesquisa de EngenhariaPrograma de Pós-Graduação em Engenharia CivilUFRJ, 2021)
On the strength and DSM design of end-bolted cold-formed steel columns buckling in distortional modes
(Universidade Federal do Rio de JaneiroBrasilInstituto Alberto Luiz Coimbra de Pós-Graduação e Pesquisa de EngenhariaPrograma de Pós-Graduação em Engenharia CivilUFRJ, 2018)
Elastoplastic behavior of welded connections in square section steel pipes submitted to monotonic loadComportamiento elastoplástico de conexiones soldadas en tubos de acero de sección cuadrada sometidos a carga monotónica
(Universidad Centroccidental Lisandro Alvarado - Decanato de Ingeniería Civil, 2019)
Instalação de capacitores de potência em redes poluídas por harmônicos e com baixa potência de curto-circuito
(Universidade Federal de Minas GeraisUFMG, 2011-05-27)
The power factor correction by means of capacitors and the proliferation of nonlinear loads in the electrical system strongly increases the probability of equipment overload due to excessive harmonic distortion. This work ...
Comportamiento experimental de conexiones soldadas entre tubos cuadrados de acero conformados por perfiles G de 60X30X10X2 y 80X40X15X3 mm sometidas a carga monotónica
(2020-07)
The objective of this research was to analyze,
through six tests, the elastoplastic behavior of
welded connections with square-shaped steel
tubes made up of 60x30x2 and 80x40x3mm G
profiles, subjected to monotonic ...
Analysis of harmonic distortion generated by PWM motor drives
(IEEE Workshop on Power Electronics and Power Quality Applications, PEPQA 2017, 2018)
Harmonic distortion evaluation generated by PWM motor drives in electrical industrial systems
(International Journal of Electrical and Computer Engineering, 2018)